Specifications are subject to change without notice (09.06.2021) 

1

DWB03, PWB03

Monitoring Relays

3-Phase Active power direction

Types DWB03, PWB03

•   TRMS active power relays for three phase  

balanced applications

•   Measuring if active power is within set limits

•   Measure their own power supply

•   Measuring ranges:  5A, 10A, MI current transformers

•   Power ON delay 1 to 30 s knob selectable

•   Separately adjustable upper/lower level on relative 

scale

•   Programmable latching or inhibit at set level 

•   Automatic and manual start and stop of the system

•   Output: 8 A SPDT relay N.D. or N.E. selectable

•   For mounting on DIN-rail in accordance with DIN/EN/

EC 60715 (DWB03) or plug-in module (PWB03)

•   45 mm Euronorm housing (DWB03) or 36 mm plug-in 

module (PWB03)

•   LED indication for relay, alarm and power supply ON

Product Description

DWB03 and PWB03 are 

precise TRMS active 

power monitoring relays for 

3-phase balanced systems. 

They can be used for mon-

itoring the actual load of 

asynchronous motors and 

other symmetrical loads, as 

well as to see if the power 

flows in the correct direc-

tion.

Start/stop input allows to 

use a manual switch to start 

and stop the system, with-

out the need of an auxiliary 

device.

The advantage of using the 

latch function is that the 

alarm status can be kept 

even after the end of the 

alarm condition.

The LED’s indicate the state 

of the alarm and the output 

relay.

Input Specifications

Input

Voltage (own power supply):

3 - phase  

DWB03: 

L1, L2, L3

 

PWB03: 

5, 6, 7

 

M23:   208 to 240 VAC ± 15%

 

DWB03CM48:   380 to 480 VAC ± 15%

 

PWB03CM48:   380 to 415 VAC ± 15%

 

DWB03CM69: 

600 to 690 VAC ± 15%

1- phase  

DWB03CM23: 

L1, L2

 

PWB03CM23: 

5, 6

 

   208 to 240 VAC ± 15%

Current: 

DWB03: 

5A, 10A: I1, I2

 

 

MI...:U1, U2

 

PWB03: 

5A, 10A: 11, 10

 

 

MI...: 9, 8

Measuring ranges 

 

Upper level  Lower level

Active power

 

  -100 to 100 % -100 to 100 %

 

 

AACrms 

Max. curr. 

 

  

(30s)

Direct input: 

 

0.5 to 5A 

30A

 

 

1 to 10A 

50A

Standard CT (examples)

TADK2 50 A/5 A 

 

5 to 50 A 

60 A

CTD1 150 A/5 A 

 

15 to 150 A 

180 A

CTD4 400 A/5 A 

 

40 to 400 A 

480 A

TAD12 1000 A/5 A 

 

100 to 1000 A  1200 A

TACO200 6000 A/5 A 

 

600 to 6000 A  7200 A

MI CT ranges 

 

MI 100 

 

10 to 100 A 

250 AAC

MI 500 

 

50 to 500 A 

750 AAC

Note:

The input voltage cannot 

raise over 300 VAC with 

respect to ground (PWB03 

only)

Contact input

DWB03 

 

Terminals Z1, U2

PWB03 

 

Terminals 2, 9

Disabled 

 

> 10 k

W

Enabled 

 

< 500 

W

Pulse width 

 

> 500 ms

Hysteresis

 

 

~ 2% of set value - fixed

DWB03

PWB03

Ordering key

Housing

Function

Type

Item number

Output

Power Supply

Range

DWB 03 C M48 10A

Type Selection

Mounting 

Output 

Supply:  

Supply: 

Supply:  

Supply:  

 

 

 

208 to 240 VAC 

380 to 415 VAC 

380 to 480 VAC 

600 to 690 VAC

DIN-rail SPDT 

DWB 03 C M23 10A 

 

DWB 03 C M48 10A 

DWB03 C M69 10A

Plug-in SPDT 

PWB 03 C M23 10A 

PWB 03 C M48 10A