background image

gas FUNNEL CAKE FRYERS

www.CarnivalKingSupplies.com

Item #382DFCG23N, #382DFCG23L, #382DFCG32N, #382DFCG32L

03/2021

user manual

Summary of Contents for 382DFCG23L

Page 1: ...gas FUNNEL CAKE FRYERS www CarnivalKingSupplies com Item 382DFCG23N 382DFCG23L 382DFCG32N 382DFCG32L 03 2021 user manual ...

Page 2: ...nce will result in years of satisfactory performance Before installing the fryer thoroughly read this manual and carefully follow all instructions This manual is applicable to the models listed on the first page Procedures in this manual will apply to all models unless specified Pictures and illustrations can be of any model unless the picture or illustration needs to be model specific Highlighted...

Page 3: ...check for possible shipping damage If the fryer is damaged save the packaging material and contact us immediately Overall Tank Interior MODEL WIDTH DEPTH HEIGHT BURNERS TANK CAPACITY WIDTH DEPTH HEIGHT BTU HOUR W C 382DFCG23L 23 2 Single 15 30 lb 21 54 000 10 382DFCG23N 23 2 Single 15 30 lb 21 54 000 4 382DFCG32L 32 3 Single 20 40 lb 21 81 000 10 382DFCG32N 32 3 Single 20 40 lb 21 81 000 4 ...

Page 4: ...ext to sides or back Codes and Standards The fryer must be installed in accordance with IN THE UNITED STATES State and local codes or in the absence of local codes with National Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition Copies may be obtained from The American Gas Association Accredited Standards Commi ee Z223 400 N Capital St NW Washington DC 20001 or the Secretary Standards Council NFPA 1...

Page 5: ...er equipment warranty Never allow anything to obstruct the flue or ventilation exiting from the fryer flue Do not put anything on top of flue area Gas Connection WARNING All gas supply connections and any pipe joint compound must be resistant to the action of propane gases The gas inlet is located on the lower rear of the fryer Codes require that a gas shuto valve be installed in the gas line ahea...

Page 6: ...TICES 1 Purge the supply line to clean out dust dirt or other foreign ma er before connecting the line to the unit 2 Use pipe joint compound that is suitable for use with both natural and LP gas on all threaded connections Leveling the Fryer Check the level of the fryer by placing a level on top of the fryer a er gas connections have been made Ensure that the fryer is level front to back and side ...

Page 7: ...es in the fryer tank Shortening will expand when heated Do not fill the fryer tank over the MAX line Add fresh shortening as needed to maintain oil level Lighting the Pilot 1 Open the door The thermostat is located behind the door 2 Make sure that thermostat is set to OFF by aligning the OFF with the red indicator 3 Push the gas control valve knob and turn to ON Wait 5 minutes for unburned gas to ...

Page 8: ...ilot knob and turn to OFF 3 Thoroughly drain the fryer Refer to DRAINING THE FRYER 4 Clean the fryer according to CLEANING 5 Turn o the main gas shuto valve Fry Guidelines 1 Set the desired temperature and allow shortening to heat up to that temperature 2 Fry items that are the same size to ensure equal doneness 3 Drain or wipe dry raw or wet foods to minimize spla er when lowering into hot shorte...

Page 9: ... cleanser to a damp cloth or sponge and rub cleanser on the metal in the direction of the polishing lines on the metal Rubbing cleanser as gently as possible in the direction of the polished lines will not mar the finish of the stainless steel NEVER RUB WITH A CIRCULAR MOTION Soil and burnt deposits that do not respond to the above procedure can usually be removed by rubbing the surface with a sco...

Page 10: ...ot oil 3 Once the shortening has been drained flush out scraps and sediment using the cleaning brush 4 Close the drain valve and fill tank water Use a low foaming cleaner degreaser to clean the fry tank Follow the instructions on the side of the package B We recommend Fryclone Boil Out Fryer Cleaner NOTICE Do not use chlorine or sulfate sulfide cleaners 5 Solution level must be between the MIN and...

Page 11: ... Gas supply not turned on Ensure gas supply pipping system is providing gas See Gas Testing instructions No heat Wire connections loose Call service No heat Wires connections need cleaning Call service No heat Thermopile Call service Insufficient or too much heat Thermostat dial not set to desired temperature Set dial to desired temperature See Turning on Fryer instructions Insufficient or too muc...

Page 12: ...12 www CarnivalKingSupplies com info carnivalking com gas FUNNEL CAKE FRYER Manual Exploded Diagram ...

Page 13: ... 38201107800L Drain board supporting rack For 382DFCG23 N A 38201107828L Drain board supporting rack For 382DFCG32 N A 382201501328 Nozzle for main burner Nat N A 38201501328L Nozzle for main burner LP 20a 382200500788 Gas valve LP 20b 382200500777 Gas valve NG N A 382819L3028L Mesh screeen with handle For 382DFCG23 N A 382837L3028L Mesh screeen with handle For 382DFCG32 25 382201304464 Main burne...