PLUMBERS INSTALLATION INSTRUCTIONS

TITAN - WALL MIXER WITH WALL BASIN OUTLET & PLATE (RH/LH)

WATER EFFICIENT TAPWARE

Hot and cold water inlet pressures should be equal.

Maximum hot water temperature : 80 C.

IMPORTANT

Pressure & Temperature Requirements.

New Regulation :-500 kPa maximum static pressure 

at any outlet within a building.

(Ref. AS/NZS 3500.1-2003, Clause 3.3.4)

Static Inlet pressure range : 150 -1000 kPa

Installation Requirements.

The installing plumber is responsible for waterproofing

all penetrations for Taps in Shower areas at installation

by a proprietary flange system or a sealant.

(Ref AS3740-2010, Clause 3.10)

+ Not supplied.

5)

Replacing Cartridge (Fig. 1)

6)

Turn off hot and cold water supplies.

1)

Carefully fit the wall cover plate (8) followed by the retaining

ring (7) onto the mixer body (12), ensuring the pin in the retaining

ring is engaged in the location slot (with the screws at the bottom).

Push the retaining ring and wall cover plate firmly against the

wall/tile face and tighten screws (6) using 2mm allen key (5). Wipe

clean any excess sealant from the decorative surfaces & the

wall/tile face. (See Fig.1)

4)

Carefully remove plug (4) before using a 2.5mm allen key

(3) to loosen grub screw (2) and remove handle (1).

Remove cap (9) taking care not to damage the decorative

finish. Unscrew nut (10) then lift out old cartridge (11).

Ensure inside face of mixer body (12) is clean. Check that

seal is in position in base of new cartridge (11). Fit new

cartridge (11) into mixer body (12), taking care that two

lugs on base of cartridge (11) fit into mating holes in mixer

body (12).

Screw on nut (10). 

Important : Nut (10) should be

tightened to a torque of 10Nm.

Replace cap (9), tightening by hand. Fit handle (1) taking

care that it is pushed fully down. Tighten grub screw (2)

then replace plug (4).

Turn on water supplies and check operation.

2)

3)

4)

5)

6)

Fit handle (1) as shown, taking care that it is pushed fully down.

Tighten grub screw (2) using 2.5mm allen key (3) then insert

plug (4).
Apply thread tape to the thread of wall elbow (14

+

).

Important: Care must be taken that thread tape cannot become

dislodged and block the flow regulating device, causing a

reduction in water flow. 

7) Apply a suitable clear sealant in the corner around the location

diameter of the retaining ring (18) to prevent water entering the

wall cavity (See Fig.4). Slide the retaining ring (18) onto the

basin outlet (13). Screw the inlet of the basin outlet (13) onto the

thread of the wall elbow (14

+

) until its base is adjacent to the wall

cover plate, then screw on a further 2-3 turns and position so that

the aerator insert is pointing down as shown, taking care not to

damage the decorative finish. DO NOT OVERTIGHTEN. Push the

retaining ring (18) firmly against the wall cover plate (8) and tighten

screws (6) using 2mm allen key (5).

Wipe clean any excess sealant from the decorative surfaces.

Turn on Hot and Cold water supplies and check operation.

8)

Installation (Fig. 1 & 3)

1)

2)

Important Information

Fit mixer body (12) onto a suitable mounting plate or noggin

in the wall and secure using screws through the holes in its

base. When facing the mixer, the connections should be as

follows : Hot water inlet connection 'H' to the left. 

              Cold water inlet connection 'C' to the right. 

              Mixed water outlet connection, vertically upwards.

Note : A suitable elbow fitting (15

+

) should be fitted to the

inlet connection adjacent to the basin outlet (13) (Fig.3). 

Check all connections for leaks.

Important :

Mixer body (12) must be installed square to wall/tile face,

to ensure wall cover plate (8) sits flush.

To avoid damaging the decorative finish, do not remove the

plastic protective sleeve until installation has been completed.

Accurately mount a wall elbow (14

+

) (or equivalent) for

connection to the basin outlet in the desired orientation 

(to the right or left of mixer body)(Fig.2).

Important :

All care should be taken that the wall elbow (14

+

) is mounted

accurately in line with, and at a distance of 90mm 2 from

the adjacent mixer body (12) and that it is square to the 

wall/tile face (Fig.3). Connect the mixer body outlet to the 

wall elbow (14

+

). 

Note: Pipework and fittings are not supplied.

*

*

Brazed connections should NOT be made directly onto

mixer, as exccesive heat will cause permanent damage.

In-wall components must be mounted accurately to

ensure tapware operates correctly when installed.

Not suitable for gravity feed systems.

All pipework must be thoroughly flushed prior to

installation, as foreign materials may block the flow

regulating device and reduce the flow of water.

Note: Aerator insert must be retightened to prevent

removal by hand.

*

*

*

*

*

Wall basin outlet is fitted with a flow regulated aerator 

insert.

The lower flow rate may not be suitable for connection to

some Instantaneous Gas Water Heaters, some

Tempering Valves, some Solar Water Heaters & some

Thermostatic Mixing Valves. Check with the

manufacturers of these products.

HOT & COLD WATER INLET PRESSURES MUST BE EQUAL. 

*

Apply a suitable clear sealant to the back face of the wall cover

plate (8), leaving an unsealed section at the bottom for drainage.

Apply a suitable clear sealant in the corner around the location

diameter of the retaining ring (7) to prevent water entering the

wall cavity (See Fig 1).

3)

Removing Aerator Insert (Fig.4)

1) Aerator insert (16) can be removed with spanner (17) provided.

2) Deposits of lime can be removed by washing in a vinegar

    solution.
3) When replacing aerator insert (16), be careful that thread 

    is engaged correctly and 'O' ring is not damaged as it enters

    the bore. Tighten securely (to prevent removal by hand)

    using spanner (17).