58HDV

Direct Vent 4---Way Multipoise

Condensing Gas Furnace

95% Downflow / Horizontal Orientations

93.5% Upflow Orientation

Product Data

95% Variable Speed

Two--Stage Heating

Furnace

FLEXIBILITY

S

Supports two--stage cooling units

S

Dual Certified venting (1 or 2 pipe), Direct Vent Furnace

S

40in (1016mm) high with wider cabinets, for ease of installation

S

Factory shipped for natural gas, with Propane Gas conversion
kits available

S

Four--way multipoise installation

S

Vent pipe can be run horizontally or vertically

S

Internal condensate drain system

SERVICE

S

Self diagnostics

S

Entire blower assembly removable

COMFORT

S

Adjustable timed blower heating Off delay

S

Adjustable timed blower cooling On/Off delay

S

Thermal lined, one piece steel cabinet for noise reduction

S

Insulated blower compartment

S

24 and 115VAC humidifier terminals

S

Electronic air cleaner terminal

S

Dehumidification option

EFFICIENCY

S

95% AFUE

S

Two--stage operation

S

ECM Variable speed DC motor

S

Two--stage Induced draft blower

S

In--shot burners

S

California NOx approved

QUALITY

S

Stainless steel heat exchanger

S

Stainless steel secondary heat exchanger

S

High temperature limit control prevents overheating

S

Direct ignition with Silicon Nitride igniton

S

Flame roll--out sensors standard

S

External filter rack with permanent filters

UNIT OPERATION HAZARD

Failure to follow this warning could result in personal injury,

death or property damage.
This furnace is not designed for use in mobile homes, trailers,

or recreational vehicles.

!

WARNING

C E RT I F I E D

D E

S I G N

C

E R

T I F I E

D

As an ENERGY STAR 
Partner, Carrier Corp.
has determined that this
product meets the 
ENERGY STAR
guidelines for energy
efficiency.

ama

UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS)

Model

Number

Dimensions H x W x D

Input

(MBTUH)

Efficiency

AFUE

Cooling Capacity

@ .5 in wc (125 Pa)

Weight

Inches

Millimeters

Lbs

Kg

58HDV040

40 x 19

1

/

8

x 29

1016 x 486 x 737

40

95

1.5 -- 3.0 TON

150

68

58HDV060

40 x 19

1

/

8

x 29

1016 x 486 x 737

60

95

1.5 -- 3.5 TON

168

76

58HDV080

40 x 22

3

/

4

x 29

1016 x 578 x 737

80

95

3 -- 5.0 TON

187

85

58HDV100

40 x 24

1

/

2

x 29

1016 x 522 x 737

100

95

3 -- 5.0 TON

203

92

Summary of Contents for 58HDV040

Page 1: ... DC motor S Two stage Induced draft blower S In shot burners S California NOx approved QUALITY S Stainless steel heat exchanger S Stainless steel secondary heat exchanger S High temperature limit control prevents overheating S Direct ignition with Silicon Nitride igniton S Flame roll out sensors standard S External filter rack with permanent filters UNIT OPERATION HAZARD Failure to follow this war...

Page 2: ...INTAKE VENT H G E F TOP AIR INTAKE KO ALTERNATE LEFT SIDE VENT 7 21 4 611 16 11 4 ELECTRICAL 413 16 11 16 111 16 17 5 16 24 1 16 19 13 16 28 3 4 29 7 8 TRAP KO UPFLOW HORIZONTAL 17 8 21 5 8 24 13 1 4 47 8 TRAP KO COUNTERFLOW 13 11 16 31 11 16 13 8 THERMOSTAT GAS A FRONT B D 23 1 8 C BOTTOM 37 8 AIR INTAKE KO ALTERNATE RIGHT SIDE VENT KO 7 11 4 ELECTRICAL KO 28 1 2 TRAP KO UPFLOW HORIZONTAL TRAP KO...

Page 3: ...CVT 2 51 mm Concentric vent kit allows single wall penetration for 2 pipe direct vent applications 90 58HDV060 58HDV080 58HDV100 KGAHA6101PSW High Altitude Pressure Switch Kit 58HDV040 KGAHA6201PSW High Altitude Pressure Switch Kit 58HDV060 KGAHA6301PSW High Altitude Pressure Switch Kit 58HDV080 KGAHA6401PSW High Altitude Pressure Switch Kit 58HDV100 KGASB0301P01 KGASB0401P02 KGASB0801P06 Combusti...

Page 4: ...P is decrease in rise Note 4 High and low heat rise values are approximate air temperature change from return air temperature when at factory default settings Table 2 Airflow DIP Switch OFF 0 ON 1 Continuous Fan 0 10 in wc 25 Pa ESP 1 2 CFM L s 00 592 279 01 1021 482 10 1346 635 11 1346 635 Factory Setting Table 3 SW2 DIP Assignments DIP Switch Blower Parameter 1 2 Cont Fan Adj 3 4 Heat Speed Adj ...

Page 5: ... 1000 1200 1400 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 0 ESP inches of wc CFM 00 00 NOM 00 01 01 NOM 01 10 10 NOM 10 11 11 NOM 11 Low Cool Airflow 0 200 400 600 800 1000 1200 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 0 ESP inches of wc CFM 00 00 NOM 00 01 01 NOM 01 10 10 NOM 10 11 11 NOM 11 58HDV ...

Page 6: ... decrease in rise Note 4 High and low heat rise values are approximate air temperature change from return air temperature when at factory default settings Table 2 Airflow DIP Switch OFF 0 ON 1 Continuous Fan 0 10 in wc 25 Pa ESP 1 2 CFM L s 00 612 475 01 1096 822 10 1403 1040 11 1403 1040 Factory Setting Table 3 SW2 DIP Assignments DIP Switch Blower Parameter 1 2 Cont Fan Adj 3 4 Heat Speed Adj 5 ...

Page 7: ...0 600 800 1000 1200 1400 1600 1800 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 ESP inchesof wc CFM 00 00NOM 00 01 01NOM 01 10 10NOM 10 11 11NOM 11 LowCoolAirflowchart 0 200 400 600 800 1000 1200 1400 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 ESP inchesofwc CFM 00 00NOM 00 01 01NOM 01 10 10NOM 10 11 11NOM 11 58HDV ...

Page 8: ...at ESP is decrease in rise Note 4 High and low heat rise values are approximate air temperature change from return air temperature when at factory default settings Table 2 Airflow DIP Switch OFF 0 ON 1 Continuous Fan 0 10 in wc 25 Pa ESP 1 2 CFM L s 00 1007 475 01 1742 822 10 2204 1040 11 2204 1040 Factory Setting Table 3 SW2 DIP Assignments DIP Switch Blower Parameter 1 2 Cont Fan Adj 3 4 Heat Sp...

Page 9: ...000 2400 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 0 ESP inches of wc CFM 00 00 NOM 00 01 01 NOM 01 10 10 NOM 10 11 11 NOM 11 LowCoolAirflow 0 200 400 600 800 1000 1200 1400 1600 1800 2000 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 0 ESP inchesofwc CFM 00 00NOM 00 01 01NOM 01 10 10NOM 10 11 11NOM 11 58HDV ...

Page 10: ...ESP is decrease in rise Note 4 High and low heat rise values are approximate air temperature change from return air temperature when at factory default settings Table 2 Airflow DIP Switch OFF 0 ON 1 Continuous Fan 0 10 in wc 25 Pa ESP 1 2 CFM L s 00 1032 487 01 1778 839 10 2178 1028 11 2178 1028 Factory Setting Table 3 SW2 DIP Assignments DIP Switch Blower Parameter 1 2 Cont Fan Adj 3 4 Heat Speed...

Page 11: ...400 1800 2200 2600 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 0 ESP inchesofwc CFM 00 00 NOM 00 01 01 NOM 01 10 10 NOM 10 11 11 NOM 11 Low Cool Airflow 0 200 400 600 800 1000 1200 1400 1600 1800 2000 0 0 0 2 0 4 0 6 0 8 1 0 ESP inches of wc CFM 00 00NOM 00 01 01 NOM 01 10 10 NOM 10 11 11 NOM 11 58HDV ...

Page 12: ...42 Copyright 2009 Carrier Corp S 7310 W Morris St S Indianapolis IN 46231 Printed in U S A Edition Date 04 09 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No 58HDV 01PD Replaces NEW 58HDV ...

Reviews: