Summary of Contents for BS1

Page 1: ...ch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Model BS1 BS2 BW1 BW2 and BW3 Gas Fired Water and Steam Boilers NOTE TO I...

Page 2: ... new boiler will continue to deliver money saving home comfort and enjoyment for many years to come Spend just a few minutes with this manual to learn the operation of your new boiler and the small amount of maintenance it takes to help keep it operating at peak efficiency MODEL BW3 INDUCED COMBUSTION WATER BOILER MODEL BWl AND BW2 WATER BOILERS MODEL BSl AND BS2 STEAM BOILERS BOILER IDENTIFICATIO...

Page 3: ...ER BOILER _ Controls limit transibnner and relay _ Water circulator Gage 77 Relief vane 77 Combination gas valve regulator and shut offcock Burners and pilot inside access door Vent damper MODEL BS12 AND BS2 STEAM BOILERS 6 1 5 MODEL BW1 AND BW2 WATER BOILERS Pressure limit control Spark generator _ID system only Low water cutoff D 1 E3 7 Burners and pitot inside access door Combination gas valve ...

Page 4: ...rmation or assistance 6 Do not use this appliance if any part has been under water hnlnediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water STARTING YOUR BOILER Your boiler is equipped with 1 of the 2 following types of gas control systems 1 The manual ignition system has a continuously bu...

Page 5: ...ue to hold control dial do am for at least 60 sec Release the control dial The pilot will remain lit Fig 14 14 NOTE If the pilot flame does not remain lit repeat steps 1 through 5 however hold the push button down for a longer period of time at least 90 sec If the pilot flame does not remain lit after this second attempt the thennocouple should be checked t _r a possible matfanction Call your deal...

Page 6: ...ext section AUTOMATIC INTERMITTENT IGNITION 1 Set your room therlnostat to the lowest telnperature setting Fig 17 2 Turn the electrical supply to the boiler to OFF Fig 18 3 Turn the control dial on the gas valve to the OFF position and wait 5 minutes Fig 19 t3 Y 17 18 4 After a_aiting5 minutes turn the control dial on the gas valve to the ON position Fig 20 5 Turn the electrical supply to the boil...

Page 7: ...will want to mm the boiler off The t _llowing procedures must be followed MANUAL IGNITION l Set your room thermostat to the lowest temperature setting Fig 23 2 Turn the electrical supply to the boiler to OFF Fig 24 23 24 3 TOshut offthe main burners but keep the pilot light burning turn the control dial to the PILOT position Fig 25 4 To shut offthe complete gas control system pilot and main burner...

Page 8: ...l _re each heating season When dirt soot scale or rest builds up your boiler can lose efficiency and perform improperly Accumulations on the main burners can result in the burners firing out ofnonnat sequence This delayed ignition wilt create an alarmingly loud sound z_xCAUTION If your boiler makes an especially loud noise when the main burners light shut down your boiler and call your dealer To i...

Page 9: ...damper if installed Inspect all combustion and ventilation air passages and openings Inspect electrical wiring connections and components for loose connections Check gas pipes leading to and inside your boiler for leaks Readjust the air gas mixture if the bumer flames are not bright blue Perform an operational checkout to determine whether your boiler is working properly and if it requires adjustm...

Page 10: ...ve in ON position Follow start up procedures if you must reset dial to ON If your boiler still tails to operate call your service representative For your convenience record the model and serial numbers of your new boiler on the form on page 2 Should you ever require service you will have ready access to the information needed by the service representative 10 ...

Page 11: ...11 ...

Page 12: ... 1999 CAC BDR RO Box 70 Indianapolis IN 46206 Form OG BS1A 03 Cancels OG BS1A 02 Printed in U S A 9 99 Catalog No 63BS 1A2 ...