Summary of Contents for Condensing gas furnace

Page 1: ...ied installer service agency or the gas supplier Al1263 CARBON MONOXIDE POISONING HAZARD Failure to follow this warning could result in personal injury and or death Carbon Monoxide is invisible odorless and toxic Install a carbon monoxide alarm in your home even if you do not own a gas appliance Locate the carbon monoxide alarm in the living area of your home and away from gas appliances and doorw...

Page 2: ...urnaces you can buy today We are proud of the technological advances incorporated into the design of this furnace With only minimal care your new furnace will deliver many years of money saving home comfort and enioyment Spend just a few minutes with this manual to learn the operation of your new furnace and the small amount of maintenance it takes to help keep it operating at peak efficiency year...

Page 3: ...OT SHOWN LOCATED ON MAIN FURNACE DOOR SEE OPERATING INSTRUCTIONS INSIDE DOOR FIGURE ELECTRICAL JUNCTION BOX IF REQUIRED LOCATION MAY VARY BLOWER DOOR SAFETY SWITCH FURNACE CONTROL BOARD RATING PLATE NOT SHOWN LOCATED ON BLOWER DOOR MAIN LIMIT SWITCH BEHIND GAS VALVE INDUCER MOTOR ASSEMBLY MEDIA CABINET BLOWER AND MOTOR CAPAC ITO R POWER CHOKE REPRESENTATIVE DRAWING ONLY SOME MODELS MAY VARY IN APP...

Page 4: ...irect vent 1 pipe Fig 3 application In a direct vent 2 pipe application your furnace uses air from outside the home for combustion and vents flue gas to the outdoors This type of application will have two pipes running from the furnace to the outdoors In some cases the inlet air pipe may be located in an area that has access to outdoor air such as an attic In all cases the outlet vent pipe must be...

Page 5: ...to shut off or if overheating occurs shut off the gas valve to the furnace before shutting off electrical supply This furnace contains SAFETY DEVICES which must be MANUALLY RESET If the furnace is left unattended for an extended period of time have it checked periodically for proper operation This precaution will prevent problems associated with no heat such as frozen water pipes etc See Before Yo...

Page 6: ...ace be sure the furnace filter is clean and in place See Perfornfing Routine Maintenance section in this manual Do not run the furnace without a filter in place Then proceed as follows Fig 9 Turn Off Electrical Supply 4 Remove the main furnace door See Fig 10 A92185 STEPS FOR STARTING YOUR FURNACE 1 Set your room thermostat to the lowest temperature setting and set the MODE to OFF See Fig 7 Fig 7 ...

Page 7: ...ec the furnace blower will start Variable capacity furnaces start at low speed until the control makes the necessary adjustments to operate the blower at either the low or high heat speed NOTE If the main burners fail to ignite after four attempts the furnace control system will lock out If lockout occurs main burners fail to light or blower does not come on shut down the furnace and call your dea...

Page 8: ...ction call your dealer as soon as possible NIT AND PROPERTY DAMAGE HAZARD Failure to follow this caution may result in unit component or property damage Furnace is not to be installed operated and then turned off and left turned off in an unoccupied structure during winter See Winterization procedures in this manual PERFORMING ROUTINE MAINTENANCE NOTE The qualified installer or agency must use onl...

Page 9: ... if dirty in a sink bathtub or outside with a garden hose Always use cold tap water A nfild liquid detergent may be used if necessary Spray water through filter in the opposite direction of airflow Allow fil ter to dry 5 Reinstall clean air filter 6 Turn on electrical supply to the furnace If your furnace air filter needs to be replaced be sure to use a factory authorized filter of the same size t...

Page 10: ...r Filter Located in Filter Cabinet FILTER CABINET HEIGHT IN MM FILTER SIZE IN MM FILTER TYPE 1 16 x 25 x 6 4 406 x 635 x 19 or Washablet 16 406 1 16x25x4 5 16 406 x 665 x 11 O 1 20 x 25 x 6 4 508 x 635 x 19 or Washablet 20 508 1 20 x 25 x 4 5 16 508 x 635 x 110 1 24 x 25 x 3 4 or 610 x 635 x 19 or Washablet 24 610 1 24 x 25 x 4 5 16 610 x 635 x 110 Filters with a side return air may have a differe...

Page 11: ...our home for blockage NOTE If your furnace makes a loud noise when the main burners are ignited shut down the furnace and call your servicing dealer Use your flashlight and follow these steps for inspecting the combustion area and vent system of your furnace CARBON MONOXIDE POISONING HAZARD Failure to follow this warning could result in personal iniury or death If dirt rust soot or scale accumulat...

Page 12: ...m collector box 10 Replace plug in collector box 11 Remove the other plug and repeat steps 4 10 12 Replace main door 13 When furnace is re started flush condensate pump with clear water to check for proper operation before re starting furnace 14 Propylene glycol need not be removed before re starting furnace UNIT COMPONENT DAMAGE HAZARD Failure to follow this caution may result in damage to the fu...

Page 13: ...ing Instructions Inside Door Al1318 BEFORE YOU REQUEST A SERVICE CALL If your furnace is not operating or not performing properly you may save the expense of a service call by checking a few things yourself before calling for service This furnace has a light emitting diode LED status code display to aid the installer service technician or homeowner while installing or servicing the unit The LED co...

Page 14: ...ER OR HEAT PUMP Model Serial INDOOR COIL Furnace Coil or Fan Coil Model INSTALLATION INFORMATION Date Installed DEALERSHIP CONTACT INFORMATION Company Name Address Phone Number Technician Name Serial NOTE TO INSTALLER This manual must be left with the equipment owner Copyright 2012 Carrier Corp 7310 W Morris St Indianapolis IN 46231 Edition Date 12 12 Manufacturer reserve8 the right to change at a...