NOTE:
Read the entire instruction manual before starting the installation.
This symbol
→
indicates a change since the last issue.
SAFETY CONSIDERATIONS
Installing and servicing heating equipment can be hazardous due to gas and electrical components. Only trained and qualified personnel should
install, repair, or service heating equipment.
Untrained personnel can perform basic maintenance functions such as cleaning and replacing air filters. All other operations must be performed
by trained service personnel. When working on heating equipment, observe precautions in the literature, on tags, and on labels attached to or
shipped with the unit, and other safety precautions that may apply.
Follow all safety codes. In the United States, follow all safety codes including the National Fuel Gas Codes NFPA No. 54-1996/ANSI Z223.1-1996
(NFGC). In Canada, refer to the National Standard of Canada Natural Gas and Propane Gases Installation Codes, CAN/CGA-B149.1 and .2-M95
(NSCNGPIC).
Wear safety glasses and work gloves. Have a fire extinguisher available during start-up operation, adjustment procedures, and service calls.
Recognize safety information. This is the safety-alert symbol
. When you see this symbol on the furnace and in instructions or manuals, be
alert to the potential for personal injury.
Understand the signal word DANGER, WARNING, CAUTION, or NOTE. The words DANGER, WARNING, and CAUTION are used with the
safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies
hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury
or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.
WARNING: This conversion kit shall be installed by a qualified service agency in
accordance with the manufacturer’s instructions and all applicable codes and requirements
of the authority having jurisdiction. If the information in these instructions is not followed
exactly, a fire, explosion, or production of carbon monoxide may result causing property
damage, personal injury, or loss of life. The qualified service agency performing this work
assumes responsibility for the proper conversion of this furnace with this kit.
In Canada, the conversion shall be carried out in accordance with the requirements of the
provincial authorities having jurisdiction and the National Standard of Canada Natural Gas
and Propane Installation Code (NSCNGPIC).
AVERTISSEMENT: Cet ensemble de conversion ne doit être installé que par le représen-
tant d’un organisme qualifié et conformément aux instructions du fabricant et à tous les
codes et exigences applicables de l’autorité compétente. Quiconque ne respecte pas à la
lettre les instructions dans le présent manuel risque de déclencher un incendie ou une
explosion entraînant des dommages matériels, des lésions corporelles ou la perte de vies
humaines. L’organisme qualifié qui effectue les travaux est responsable de la conversion
correcte de ce générateur d’air chaud à l’aide de cet ensemble.
INTRODUCTION
This instruction covers the installation of gas conversion kit Part No. KGAPN20012SP to convert the following furnaces from propane gas usage
to natural gas usage. See the appropriate section for your furnace type.
®
CANADIAN GAS ASSOCIATION
A PP R O VED
R
Installation Instructions
KGAPN20012SP
Gas Conversion Kit
Propane-to-Natural for
Variable-Speed and
2-Speed Furnaces
Form:
AG-GAPN-13
Cancels:
AG-GAPN-12
Printed in U.S.A.
8-97
Catalog No.
63GA-PN0