Installation and User Instructions

NOTE: 

Read the entire instruction manual before starting the 

installation.

INTRODUCTION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

HOW IT WORKS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

APPLICATION CONSIDERATIONS. . . . . . . . . . . . . . . . . . . . . . . . 2

INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

START-UP and OPERATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

ERROR and STATUS CODES  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

INTRODUCTION

Congratulations  for  selecting  the  Return  Air  Purifier  for  your  home

comfort system! As part of a strategy for slowing the spread of infectious

disease  in  your  home,  the  Return Air  Purifier  should  be  considered

essential.  Featuring  our  patented  Captures  &  Kills®  technology,  the

Return Air Purifier offers proven, third-party tested effectiveness with a

99% inactivation of captured viruses and germs when used as instructed,
including:

1

• Coronavirus

• Common cold surrogate

• Bacteria that causes strep throat

• Human influenza
The Return Air Purifier is a cornerstone of Healthy Home Solutions for

providing healthier, cleaner air in your home.

HOW IT WORKS

The Return Air Purifier provides extremely high filtration performance

while killing captured contaminants, including viruses and bacteria. The

Return Air Purifier treats the entire air-stream through a state of the art,

three-stage process.

• In stage one, the particles are electrically charged by a precision-point

ionization array as they enter the Return Air Purifier.

• In stage two, the charged particles are electrically attracted to the air

purification cartridge.

• In stage three, captured particles are killed by electrical current flow

and ion bombardment. 

The  Return  Air  Purifier  is  Listed  to  applicable  UL  Standards  and

requirements by Underwriters Laboratories Inc.

A200506

Fig. 1 – RGAP(A,B)XX Unit

SAFETY CONSIDERATIONS

Improper  installation,  adjustment,  alteration,  service,  maintenance,  or

use can cause explosion, fire, electrical shock, or other conditions which

may  cause  death,  personal  injury  or  property  damage.  Consult  a

qualified  installer,  service  agency  or  your  distributor  or  branch  for

information  or  assistance.  The  qualified  installer  or  agency  must  use

factory-authorized  kits  or  accessories  when  modifying  this  product.

Refer to the individual instructions packaged with the kits or accessories

when installing.
Follow  all  safety  codes.  Wear  safety  glasses,  protective  clothing,  and

work gloves. Have a fire extinguisher available. Read these instructions

thoroughly and follow all warnings and cautions included in literature

and  attached to the  unit.  Consult  local building  codes  and the  current

edition of the National Electrical Code (NEC) NFPA 70.
In Canada, refer to the current editions of the Canadian Electrical Code

CSA C22.1.
Recognize safety information. When you see this symbol   on the unit

and  in  instructions  or  manuals,  be  alert  to  the  potential  for  personal

injury.  Understand  the  signal  words  DANGER,  WARNING,  and

CAUTION.  These  words  are  used  with  the  safety-alert  symbol.

DANGER identifies the most serious hazards, which will result in severe

personal  injury  or  death.  WARNING  signifies  hazards,  which  could

result in personal injury or death. CAUTION is used to identify unsafe

practices,  which  may  result  in  minor  personal  injury  or  product  and

property  damage.  NOTE  is  used  to  highlight  suggestions  which  will

result in enhanced installation, reliability, or operation.

RGAP(A,B)XX

Return Air Purifier
Size 1625

1. The air purifier has demonstrated effectiveness against the murine coronavirus, based on 

third-party testing (2020) showing a >99% inactivation, which is a virus similar to the 

human novel coronavirus (SARS-CoV-2) that causes COVID-19. Therefore, the air 

purifier can be expected to be effective against SARS-CoV-2 when used in accordance 

with its directions for use. Third-party testing (2012, 2007) also shows  ≥99% inactivation 

for the type of virus that causes common colds, Streptococcus pyogenes and human 

influenza. Airborne particles must flow through your HVAC system and be trapped by the 

filter to be inactivated at 99%.

Summary of Contents for RGAP Series

Page 1: ...r property damage Consult a qualified installer service agency or your distributor or branch for information or assistance The qualified installer or agency must use factory authorized kits or accessories when modifying this product Refer to the individual instructions packaged with the kits or accessories when installing Follow all safety codes Wear safety glasses protective clothing and work glo...

Page 2: ...erminals provide power only when the furnace blower is operating Return Air Purifier RGAPAXX1625 is designed to be powered from the electronic air cleaner EAC terminals on a furnace electronic control Accessory Safety Screen KIT170000 Electrical Power Fusing with Furnace Return Air Purifier RGAPAXX1625 does not include in line fuses as it is designed to be powered from the electronic air cleaner E...

Page 3: ...blocks and attach to the trusses to form a box to frame in the unit b If blocking has been completed by others verify the frame measurement is correct and make adjustments if needed A200494A Fig 4 Rough in CAUTION CUT HAZARD Failure to follow this caution may result in personal injury Sheet metal parts may have sharp edges or burrs Use care and wear appropriate protective clothing and gloves when ...

Page 4: ... box knockout 11 Electrical Connections Fig 8 Fig 15 and Fig 16 NOTE Use proper strain relief when installing wiring to junction box a For Furnace Units Connect wiring from the EAC terminals to a unit disconnect switch in the attic and then connect the wiring from the disconnect to the electrical box on the unit using a proper UL rated fitting at the electrical box knockout on the unit Follow stan...

Page 5: ...on filter 18 Install the filter cartridge Fig 13 in the correct orientation Follow the steps per To replace the Return Air Purifier filter cartridge complete the following steps on p7 and switch on the air purifier IMPORTANT Make sure the metal tabs on the leading edge of the filter case are inserted first They must not be visible after the filter is installed Follow the instructions printed on th...

Page 6: ...access to the incoming power wiring compartment Affix the ends of the wire or conduit to the fan coil unit and electrical box with proper UL rated fittings 2 Remove the yellow and black primary wires from the fan coil air handler transformer terminals and connect the quick connect piggyback terminals of the quick connect kit leads exiting the air purifier power conduit assembly to the transformer ...

Page 7: ...ing steps Turn the heating and cooling system power off IMPORTANT Use of any filter cartridge in the Return Air Purifier other than the genuine replacement purifier cartridge listed in the table below will likely result in poor performance and may constitute a safety hazard Do not use any third party air filters in the Return Air Purifier 1 Open the return air grille cover 2 Unlatch the unit and s...

Page 8: ...Gently stroke the ionization pins with the brush Use a gentle back and forth brushing motion to clean any small accumulations from the tips of the points If desired use a vacuum cleaner with brush attachment to gently vacuum the frame and components of enhancement module Also if an Accessory Safety Screen is installed vacuum the Safety Screen to remove accumulated dust and debris If further cleani...

Page 9: ...troubleshooting procedures A11370 Fig 22 Removal of Deposits from Ionization Pins CAUTION SAFETY HAZARD Failure to follow this caution may result in personal injury or equipment damage The following instructions are for use by qualified personnel only WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death The following procedures will expose electri...

Page 10: ...ce flow sensor bypass assembly available as replacement kit KIT161000 One or more of the three airflow sensor contact springs on purifier cabinet downstream rail are bent or damaged Replace flow sensor contact spring assembly included as part of the flow sensor kits KIT160000 and flow sensor bypass kit KIT161000 Table 2 Start Up Error Codes INDICATOR LIGHT CODE EXPLANATION POSSIBLE CAUSE RECOMMEND...

Page 11: ...ng the Return Air Purifier A200505A Fig 23 Dimensions Table 3 Operating Error Codes INDICATOR LIGHT CODE EXPLANATION POSSIBLE CAUSE RECOMMENDED ACTION 4 FLASHES Ionizer filter current imbalance Dirty Filter Enhancement Module FEM Clean service Return Air Purifier unit Damaged Filter Enhancement Module FEM Replace the filter enhancement module 5 FLASHES Over current fault Excessively dirty Damaged ...

Page 12: ...Replacement Component Kits and Accessories DESCRIPTION PART NUMBER Filter Enhancement Module FEM KIT145000 Power Supply Assembly KIT159000 Accessory Safety Screen Kit KIT170000 Current Sensing Relay Kit HN72ZA001 Service Quick Kit 344872 751 Included standard with the RGAPBXX1625 Flow Sensor KIT160000 Included standard with the RGAPBXX1625 Flow Sensor Bypass KIT161000 Included standard with the RG...