1
Operation Guide 5164 (EFX)
MA1002-EA
Getting Acquainted
Congratulations upon your selection of this CASIO watch. To get the most out of your
purchase, be sure to read this manual carefully.
For a watch with an elapsed time bezel
•
Rotate the elapsed time bezel to align the
mark with the
minute hand. After a certain amount of time has elapsed,
read the graduation on the elapsed time bezel which the
minute hand points to. The elapsed time is indicated.
Some water resistant models are equipped with a screw
•
lock crown.
With such models, you must unscrew the crown in the
•
direction noted in the illustration to loosen it before you can
pull it out. Do not pull too forcibly on such crowns.
Also note that such watches are not water resistant while
•
their crowns are loosened. Be sure to screw the crowns
back in as far as they will go after making any setting.
About This Manual
Button operations are indicated using the letters shown
•
in the illustration.
General Guide
Crown Positions
First click (Setting day)
Second click (Setting time)
Crown (Normal position)
Timekeeping
Your watch lets you set two different times: one time with the hour and minute hands,
and another time with the 12-hour and 24-hour hands.
<Time with the hour and
minute hands (Dual Time)>
<Time with the 12-hour and
24-hour hands (Basic Time)>
Hour hand
Minute hand
24-hour hand
12-hour hand
The time indicated by the hour hand and minute hand (Dual Time) can be set to the
time you want without stopping watch operation.
You can set the 12-hour and 24-hour hands to your basic time (the current time in the
time zone where you normally use the watch), and change the hour hand to any other
time (Dual Time) you want (current time in a city you are visiting, etc.).
When setting the time, make sure that the date setting is correct. If it isn’t, correct the
date setting.
To change the time setting
24-hour hand
Minute hand
Second click
Crown (Normal position)
12-hour hand
As the second hand reaches the 12 o’clock position, pull the crown out to the
1.
second click. This will cause the second hand to stop.
Rotate the crown to move the minute hand to adjust the 12-hour hand, 24-hour
2.
hand and minute hand. Though the minute, hour, 12-hour, and 24-hour hand
movements are coordinated with each other, the hour hand can be moved
independently to indicate a second time (Dual Time). For more information about
setting the hour hand, see “To adjust the hour hand setting (Dual Time)”.
Carefully set the time, making sure to distinguish between AM and PM.
•
Push the crown back in to the normal position to resume timekeeping.
3.
Elapsed time bezel
To adjust the hour hand setting (Dual Time)
Crown (Normal position)
First click
Hour hand
Pull out the crown to the first click. Normal timekeeping will continue at this time.
1.
Rotate the crown towards you (in the direction of the arrow in the illustration) to
2.
adjust the hour hand setting.
The position of the hour hand depends on the current minute.
•
Carefully set the hour hand time, making sure to distinguish between AM and PM.
•
Push the crown back in to the normal position.
3.
To change the day setting
Crown (Normal position)
First click
Day
Pull the crown out to the first click.
1.
Set the day by rotating the crown away from you (in the direction of the arrow in
2.
the illustration).
Avoid changing the day setting while the hour hand time is between 9:00 p.m.
•
and 1:00 a.m.
Push the crown back in to the normal position.
3.
Using the Stopwatch
The stopwatch lets you measure elapsed time up to 59 minutes, 59 seconds.
To measure elapsed time
Press
1.
A
to start the stopwatch.
Press
2.
A
to stop the stopwatch.
You can resume the measurement operation by
•
pressing
A
again.
Check the elapsed time.
3.
Press
•
B
to reset the stopwatch.
Notes:
Do not try to perform stopwatch operations while the crown is pulled out either to
•
the first or second click.
If the starting positions of the stopwatch minute hand and second hand become
•
misaligned, use the following procedures to adjust the positions of the hands so
they point to 12 o’clock when the stopwatch is reset.
To adjust the positions of the stopwatch second hand
Press
1.
B
to reset the stopwatch, and check the alignment of the stopwatch second
hand.
Pull out the crown to the second click.
2.
Press
3.
A
to move the stopwatch second hand.
To return the minute hand to the 12 o’clock position, press
4.
B
.
After making the adjustments you want, push the crown back in to its normal
5.
position.
Note that pulling the crown out also stops the timekeeping second hand. After
•
performing the above procedure, you should also adjust the timekeeping setting.
Specifications
Accuracy at normal temperature:
± 20 seconds a month
Display:
4 analog hands (timekeeping 12-hour, hour and minutes, stopwatch
seconds), 3 dials (timekeeping 24-hour, seconds, stopwatch minutes), and
day
Stopwatch function:
Measuring capacity: 59’59”/Measuring unit: 1 second
Measuring mode: Elapsed time
Battery:
One silver oxide battery (Type: SR626SW)
Approximately 2 years on type SR626SW (assuming one stopwatch operation
60 min./day)
Stopwatch minute hand
Stopwatch second hand