background image

Model 1222-E

Operation & Maintenance Manual

www.cavidyne.com

Summary of Contents for Caviblaster 1222-E

Page 1: ...Model 1222 E Operation Maintenance Manual www cavidyne com ...

Page 2: ...2 Figure 3 5 To supply water to the CaviBlasterTM power unit connect a 1 25 mm diameter feed hose to the cam lock plug on the inline strainer inlet Figure 4 Either fresh water or seawater can be used with this system The water source must supply the CaviBlasterTM with water at a volume of greater than 12 gallons 45 liters per minute at a maximum pressure of 70 psi 5 bar Ensure that the feed hose i...

Page 3: ... to the quick connect plug under the pressure regulating unloader Figure 6 The high pressure hose has a brass quick connect socket on the end The 1222 E CaviBlasterTM can deliver the required pressure utilizing up to 300 feet 100 meters of diameter rubber hose or 600 feet 200 meters of thermoplastic hose Using greater lengths or smaller diameters of hose may degrade performance If greater hose len...

Page 4: ...motor 10 The system is now ready to operate refer to photo on cover for overall system set up Figure 8 Figure 9 WARNING Although the CaviBlasterTM system is safe to use when submerged in water the system generates a high pressure up to 2 200 psi water stream which can cause injury when the Zero Thrust Gun is out of the water ALWAYS keep the Zero Thrust Gun submerged when the pressure pump is engag...

Page 5: ...g 6 Ensure that the Zero Thrust Gun is submerged any time the motor and pressure pump are operating Adjusting the CaviBlasterTM system for maximum performance 1 If using a calibration pressure gauge situated between the pressure hose and the CaviBlasterTM Zero Thrust Gun the water pressure should be 2 200 psi with the Zero Thrust Gun submerged and the Zero Thrust Gun trigger in the open or ON posi...

Page 6: ...n the open or ON position Shutting down the CaviBlasterTM power unit 1 Stop the motor by depressing the red STOP button Figure 8 on the motor controller 2 Shut off the supply of water to the pump 3 Squeeze the Zero Thrust Gun trigger to the open or ON position Figure 9 to release the water pressure remaining in the hose s while the Zero Thrust Gun is submerged 4 It is now safe to remove the Zero T...

Page 7: ...submerged in the water Apply hearing protection if the diver is not wearing a helmet 7 Start the motor 8 Activate the cleaning cavitation stream by squeezing the Zero Thrust Gun trigger to open or ON 9 Proceed with cleaning 10 Stop the motor 11 Shut off the water supply to the pump 12 Release pressure from the hose s by squeezing the Zero Thrust Gun trigger to the open or ON position while under w...

Page 8: ...n particular to the nails The gloves will absorb most of the energy produced by bursting cavitation bubbles and prevent the cavitation bubbles from contacting the operators hands The gloves will also protect operators hands from the initial shockwave when the Zero Thrust Gun is activated Serious harm and injury may result from the misuse of CaviBlasterTM system equipment or improperly selected fit...

Page 9: ...Page 9 For more information please email sales cavidyne com or call 1 352 275 5319 ...