background image

Summary of Contents for SUL100

Page 1: ...c i 0 0 3 0 ...

Page 2: ...for charging dry cell batteries that are commonly used with home appliances These batteries may burst and cause injury to persons and damage to property ix NEVER CHARGE A FROZEN BATTERY PRIOR TO INSTALLATION COMMISSIONING Clean battery terminals Be careful to keep corrosion from coming in contact with eyes Add distilled water in each cell until battery acid reaches level specified by battery manuf...

Page 3: ......

Page 4: ...as as not to become loose during normal use on engine Adequate consideration should be given to ventilation for proper heat dissipation WALL MOUNTED ENCLOSURE MODELS ESUL100 ESUL120 The charger must be mounted as shown in Figure 2b The lower face is removed by unscrewing the four fixing screws The face is removed by sliding the face backward thereby releasing the feet from their fixing holes Cable...

Page 5: ... overvoltage from alternator Com Common N O Normally Open N C Normally Closed See notes on connection of charge fail see right Boost Boost Initiate Linking these two connectors will force the charger from into a single boost cycle of operation Once the charger has completed a single boost cycle as outlined on page 1 of these instructions the charger returns to it s normal mode of operation Strippe...

Page 6: ...rect voltage charger YES Is output voltage correct polarity on terminals NO Check fuses and wiring YES Is battery charger correct size for battery NO Replace with correct size charger YES Min Charge Current AH Capacity of batteries 10 Max Charge Current AH Capacity of batteries 5 Wet NiCad Refer to genset manual for sizing of battery chargers to generator set If installing your own chargers batter...