background image

TORQUE MEASUREMENT

2 YEAR WARRANTY 

(RESTRICTIONS APPLY)

Imada, Inc. warrants its products to the original purchaser to be free from defects in

workmanship and material under normal use and proper maintenance for two years (one
year for adapters, attachments, batteries, and cables) from original purchase. This warranty
shall not be effective if the product has been subject to overload, shock load, misuse,
negligence, accident or repairs attempted by others than Imada, Inc.

During the warranty period, we will, at our option, either repair or replace defective

products. Please call our customer service department for a return authorization number
and return the defective product to us with freight prepaid.

The foregoing warranty constitutes the SOLE AND EXCLUSIVE WARRANTY, and we hereby

disclaim all other warranties, express, statutory or implied, applicable to the products and/or
software, including but not limited to all implied warranties of merchantability, fitness, non-
infringement, results, accuracy, security and freedom from computer virus. In no event shall
Imada, Inc. and/or its affiliated companies be liable for any incidental, consequential or
punitive damages in connection with the use of its products and/or software.

03/09

Complete color 

catalog available.

Call 800-373-9989

or E-mail us. 

Specifications subject to change without notice.

Imada, Inc.

®

3100 Dundee Rd., Suite 707, Northbrook, IL 60062 USA
Telephone: (847) 562-0834     Fax: (847) 562-0839
Web Site: www.imada.com   E-mail: imada@imada.com
ISO 9001 & ISO/IEC 17025 Accredited

Digital Torque

Screwdriver

INSTRUCTION MANUAL

Model: DID-4

Summary of Contents for DID-4

Page 1: ...t prepaid The foregoing warranty constitutes the SOLE AND EXCLUSIVE WARRANTY and we hereby disclaim all other warranties express statutory or implied applicable to the products and or software including but not limited to all implied warranties of merchantability fitness non infringement results accuracy security and freedom from computer virus In no event shall Imada Inc and or its affiliated com...

Page 2: ... 100ºF Do not apply torque exceeding the rated capacity 35 lbf in regardless of whether the unit is On or Off Avoid shock load When charging the battery be sure to use the provided AC adapter charger exclusively Do not use lacquer thinner or any solvent to clean the unit Do not disassemble or modify the unit Digital Torque Tester Screwdriver Model DID 4 List of Equipment DIgital Torque Tester Scre...

Page 3: ...AC charger adapter receptacle RESET System reset button 1 2 3 4 5 6 7 8 9 10 6 7 8 9 10 2 1 3 4 5 Measuring range 2 0 560 0 ozf in 0 20 35 00 lbf in 0 20 40 00 kgf cm 2 0 400 0 N cm 0 2 4 000 N m Accuracy 0 5 F S 1 LSD Display 4 digit LCD Operation CW CCW and fixed position Measuring modes PP Peak Mode displays PEAK torque value that will not change until a higher value is measured PD Peak Down Mo...

Page 4: ...t PP appears on the display PD Mode First Peak capture first peak value peak data output PD appears on the display C Mode Continuous RS 232 output Display and output torque transients 180 data sec C appears on the display 2 Insert Phillips tip into the screwdriver 3 To select ratchet operation turn the ratchet one click clockwise or counter clockwise from the center position To disable ratcheting ...

Page 5: ... place and press the UP to select values then press PRG to enter CLO sets the start and stop trigger points for Continuous data output When torque reaches the CLO value the tester starts to output data and stops if torque falls below the value Note the display does not show any value below the CLO minimum 5 Auto Zero Reset AC After Continuous Data Output Minimum is entered AC is dis played then th...

Page 6: ...on and value Clearing Data from Memory Single clear Press MEM then press UP or DOWN to move to a memory location When the desired memory value is displayed press CLR CLR is displayed Press CLR again to clear the data and is displayed to confirm deletion All clear Press CLR and hold until the display shows ALL then press CLR again and is displayed to confirm deletion Downloading Memory Data 1 Press...