The Central Model ESFR-1 Early
Suppression Fast Response
Automatic Sprinkler has been
designed to meet high challenge fire
hazards.

The Model ESFR-1 utilizes a
160°F/71°C or a 212°F/100°C Fast
Response solder link, giving the
sprinkler the required fast response
characteristics.

The fast response, combined with
water droplet size and velocity
provide early suppression to high
challenge fires.

The ESFR-1 is approved for use with
storage up to 35 feet in 40 foot
buildings and 25 feet in 30 foot
buildings, as referenced in the NFPA
Standards, Underwriter's
Laboratories and Factory Mutual's
installation standards.

A head guard is available for use with
the ESFR-1.  It must be assembled at
the factory, so be sure to specify it
when ordering.

3 - 9 6

ESFR-1

Early Suppression
Fast Response

Pendent Automatic Sprinkler

Model:  ESFR-1

Style:

Pendent

Wrench:  ELO/ESLO/ESFR-1

Combination

Orifice Size:  0.69"

K-Factor:  14.0

Thread Size:  

3

/

4

" N.P.T.

Temperature Rating:  160°F/71°C.

212°F/100°C

Approvals:  U.L., U.L.C., F.M., M.E.A.

(424-93-E-ESFR-1)

Maximum Working Pressure:  175 psi

Factory Hydro Test: 100% at 500 psi

Standard Finish:  Brass

Length:

4

3

/

4

"

Width:

2

3

/

4

"" (frame arms)

Weight:

8.2 oz.

Patents:

Patents are pending.

Technical
Data

Product
Description

ESFR

E a r l y
S u p p r e s s i o n
F a s t
R e s p o n s e
A u t o m a t i c
S p r i n k l e r

Manufactured by:  Central Sprinkler Company
451 North Cannon Avenue, Lansdale, Pennsylvania 19446

No. 2-13.0

U

G

c

OBSOLETE

Summary of Contents for ESFR-1

Page 1: ...standards A head guard is available for use with the ESFR 1 It must be assembled at the factory so be sure to specify it when ordering 3 96 ESFR 1 Early Suppression Fast Response Pendent Automatic Sprinkler Model ESFR 1 Style Pendent Wrench ELO ESLO ESFR 1 Combination Orifice Size 0 69 K Factor 14 0 Thread Size 3 4 N P T Temperature Rating 160 F 71 C 212 F 100 C Approvals U L U L C F M M E A 424 9...

Page 2: ... Pendent Sprinkler Note All ESFR 1 Sprinklers are factory shipped with protective cardboard guards DO NOT REMOVE IT PRIOR TO SPRINKLER INSTALLATION AFTER SPRINKLER INSTALLATION BE SURE TO REMOVE IT 2 3 4 4 3 4 3 4 NPT 1 15 16 O B S O L E T E ...

Page 3: ... requirements and standards or any alteration to the sprinkler itself will void any warranty made by Central Sprinkler Company In addition installation must also meet local government provisions codes and standards as applicable The system piping must be properly sized by hydraulic calculation to ensure the minimum required flow rate at the sprinkler Install sprinklers after the piping is in place...

Page 4: ...ugh a network of Central Sprinkler distribution centers You may write directly to Central Sprinkler Company or call 215 362 0700 for the distributor nearest you Patents Patents are pending Conversion Table 1 inch 25 400 mm 1 foot 0 3048 M 1 pound 0 4536 kg 1 foot pound 1 36 Nm 1 psi 6 895 kpa 0 0689 bar 0 0703 kg cm2 1 U S gallon 3 785 dm3 3 785 liters Conversions are approximate I Central Sprinkl...

Reviews: