background image

 

 

 USER’S MANUAL 

 

MaxPower 1000 UPS 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

Uninterruptible Power System 

 

 

28-2MAXPO0019 

Summary of Contents for MaxPower 1000

Page 1: ...USER S MANUAL MaxPower 1000 UPS Uninterruptible Power System 28 2MAXPO0019 ...

Page 2: ...RTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for the model MaxPower 1000 that should be followed during installation and maintenance of the UPS and batteries ...

Page 3: ...ecting the utility power to UPS switch ON once a month for 24 hours to avoid a full battery discharge z Please do not use the UPS in excess of the rated load capacity z The UPS contains one two large capacity batteries So the shell shall not be opened otherwise such dangers as electric shock will be caused If any internal overhaul or replacement of the battery is required please contact the distri...

Page 4: ...sible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole of the battery when maintenance or service work inside the UPS is necessary z The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible z In case smoke is found coming out from the device please cut off the power supply quickly and cont...

Page 5: ...el Power Switch 1 UPS status Indicator AC Mode Green lighting Battery Mode Green flashing 3 Fault LED Red flashing Back Panel 1 Output receptacles 2 Fuse 3 AC Input with AC fuse 4 AC Input 5 Modem Phone Line Surge Protection Option ...

Page 6: ... during shipping and the battery should be recharged prior to use Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 10 hours with no load no electrical devices such as computers monitors etc connected 3 Placement Install the UPS unit in any protected environment that provides adequate airflow around the unit and is free from exce...

Page 7: ...ntinuously for 1 second and the UPS turns into its normal state the green light is on and the beeper is off after it performs a self diagnosis the beeper and the red and green indicator lights are on for several seconds At this time user may turn on the PC and other loads Press the switch of the UPS continuously for 1 second to turn off the UPS Note 1 For the convenience of maintenance please turn...

Page 8: ...oad of the UPS 1 Remove some non critical load 2 Battery voltage is too low 2 Charge battery 8 hours or more When power failure backup time is short 3 Battery defect due to high temperature operation environment or improper operation to battery 3 Replace with the same type of battery 1 Fuse is blown 1 Replace the same type of fuse Mains normal but LED is flashing 2 Power cord is loose 2 Reconnect ...

Page 9: ...ery Mode Green LED flashing every second Fault Red LED lighting Battery weak Vbat 24V at AC Mode Red LED flashing every 2 seconds for 30 seconds Battery Fault at AC Mode Red LED flashing three times every 2 seconds INDICATOR Overload Red LED flashing twice every second Battery Mode Sounding every 4 seconds Low Battery at Battery Mode Sounding every second Fault Continuously sounding Battery weak V...