This manual describes the installation and operation of the Model S244E non-catalytic wood heater. This
heater meets US Environmental Protection Agency’s emission limits for wood heaters. Under specific
conditions this heater has been shown to deliver heat at rates ranging from 10,600 to 26,100 BTU per hour.
6” Flue Required
Figure A: Clearance from combustible constructions
From Heater From Chimney Connector
Sidewall.......... 18” (457 mm)
Sidewall.................25-1/2” (648 mm)
Backwall...............15” (381 mm)
Backwall................17-1/2” (445 mm)
Corner....................7” (175 mm)
Corner....................15”
(381 mm)
Ceiling....................56”
(1422 mm)
A
D
B
E
C
F
G
Model No. S244E
This unit has been listed by Warnock
Hersey Limited to meet or exceed
ULC S-627 Canada and UL 1482 U.S.
Part No S19212 Rev12
NOTE: Retain this sheet for future reference
A minimum clearance of 18” (457mm) to the chimney connector
may be required by the authority having jurisdiction.
MADE IN CANADA BY CFM Corporation, 410 Admiral Boulevard, Mississauga, ON. L5T 2N6 800-668-5323 www.cfmcorp.com
Unit must be placed on a noncombustible floor protection equivalent to 3/8” millboard.
Floor protector must have min. R value of .446
Consult your local building authorities for further information.
Contact your local building inspector
prior to installation.
A permit maybe required in your area.
HANDLE
Twist spring handle
in counter
clockwise motion while pushing on to handle;
spring handle will “thread” down to desired
location.
SPRING
CAUTION: BRICK FOR ASH DRAWER
MUST BE INSTALLED BEFORE
OPERATION OF WOOD HEATER
OPTIONAL FAN
An optional heat exchange blower is available for
this wood burning appliance. To order please see
the local dealer where you purchased your appliance.
CAUTION:
Do not open fire-door to a point where it
would be in contact with the combustible sidewall.
B
E
A
D
8”(203mm)
BACK WALL
SIDE W
ALL
BACK WALL
C
F
C
F
SIDE W
ALL
Figure “A”
*16
**18
*16”(406mm) U.S.A.
**18”(457mm) Canada
8”(203mm)
8”(203mm)
Inlet Air Control Settings
Desired Burn Setting Inlet Air Setting **Approx. BTU Output
Low Closed Fully 10,600
Med / Low ¼ Open 12,118
Med / High ¾ Open 19,413
High Fully Open 26,100
**Performance may vary depending on actual home operating conditions
2 FULL BRICKS
BAFFLE ASSEMBLY
BE SURE TO INSTALL TWO
FULL BRICKS (S16040) IN
BAFFLE AS SHOWN
DECORATIVE BRASS TRIM
Be sure to remove the protective plastic
coating after installing your wood heater
DESCRIPTION
PARTS LIST
1
DOOR ASSEMBLY
1
DOOR - NO GLASS
2&3
GLASS AND GASKET
3
1/8” GLASS GASKET
4
SPRING HANDLE
5
AIR CONTROL SPRING HANDLE
6
5/8” DOOR GASKET
7
GLASS CLIP
SCREW
9
HINGE PIN
10
PUSH NUT
11
FIREBRICK LT 9”x4-7/16”x1-1/4”
12
FIREBRICK LT 7-1/4”x4-7/16”x1-1/4”
13
FIREBRICK LT - ANGLED
14
BRASS ASH FENDER TRIM
15
ITEM NO.
QTY
DESCRIPTION
NO.
LISTE DES PIÉCES
PORTE MONTÉE
PORTE - SANS LA VITRE
VITRE DE JOINT D’ÉTANCHEITÉ
JOINT DE LA VITRE 1/8po
POIGNÉE À RESSORT
POIGNÉE POUR L’ADMISSION D’AIR
JOINT DE LA PORTE 5/8po
FERRURE POUR LA VITRE
VIS
GOUPILLE DE CHARNIÈRE
ÉCROU À RESSORT
BRIQUE 9”x4-7/16”x1-1/4”
BRIQUE 7-1/4”x4-7/16”x1-1/4”
BRIQUE - COUPLÉE EN ANGLE
LEYENDA NO.
DESCRIPCIÓN
NO.de PC
LISTA DE PIEZAS
1
UNIDAD DE PUERTA
S31008
1
UNIDAD DE PUERTO SIN VIDRIO
S41062
1
VIDRIO Y EMPAQUETADURA
S31117
4.0’
EMPAQUETADURA DE 1/8” PARA EL VIDRO
S15001
1
MANGO CON RESORTE
S11007
1
MANGO CON RESORTE PARA EL REGULADOR DEL AIRE
S11008
4.5’
EMPAQUETADURA DE 5/8” PARA LA PUERTA
S15011
3
PRESILLA PARA EL VIDRIO
S37018
6
TORNILLO
S11086
2
DEPIENDA ALFILER
S11005
2
UNIDAD DEL DEFLECTOR
S11090
1
LADRILLO REFRACTARIO LT 9”x4-7/16”x1-1/4”
S32217
1
LADRILLO REFRACTARIO LT 7-1/4”x4-7/16”x1-1/4”
S32023
4
LADRILLO REFRACTARIO LT - ANGULADO
S16043
12
S16040
S16042
2
QTÉE
CANT. ART NO.
PART NO.
8
BRASS BODY TRIM
GARANTURE DE CHASSIS (LAITON)
MOLDURA DE LATÓN PARA EL CUERPO DEL CALEFACTOR
GARANTURE DE GARDE-FEU (LAITON)
MOLDURA DE LATÓN PROTECTORA DEL DEPÓSITO DE CENIZAS
6
12
11
10
9
1
2
3
4
5
7
8
Brick Pattern
Disposition Des Briques
Diseño de colocación de los ladrillos
14
14
14 14
13
13
13
13
13
13
13
13
15
15
3FT(1M) MIN
FROM ROOF
PENETRATION
MINIMUM OVERALL
HEIGHT FROM FLOOR
15FT(5M)
G
2ft(635mm) HIGHER THAN
NEAREST POINT OF
ROOF WITHIN 10ft(3M)