Page 1: ...LiftMaster Cloud Connected Access Portal High Capacity INSTALLATION MANUAL Model CAPXL ...

Page 2: ...egal Single action exits may be required ALWAYS obtain proper permits and approvals in writing BEFORE installing equipment Safety Safety Symbol and Signal Word Review When you see these Safety Symbols and Signal Words on the following pages they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them The hazard may come from something...

Page 3: ...Master Cloud Account 10 INSTALL 2 Remove Knockouts 11 Mount the CAPXL 12 Install Antennas 13 Install the Ground 14 Connect Power 15 NETWORK 3 Connect Internet 16 Validate Setup 16 ACCESS CONTROL 4 Gate Access Wired 17 Gate Access Wireless 18 Door Access 19 Card Reader 20 Wiegand Output 21 Postal Lock 22 Auto Call Feature 23 Wiring Diagram 24 Repair Parts 25 Accessories 25 Configuration Sheet 26 Leg...

Page 4: ... Doors 1 2 LOOP DETECTOR BOARD MOUNTING LOCATION CAMERA MOUNTING BRACKET Security 2 0 RADIO ANTENNA Wi Fi ANTENNA POSTAL LOCK SWITCH DISPLAY TOUCHSCREEN SPEAKER LOCK POSTAL LOCK LOCATION PROXIMITY READER LOCATION CAMERA WINDOW MICROPHONE RADIO ANTENNA CONNECTION Wi Fi ANTENNA CONNECTION DOOR BOARD 2 Doors 3 4 MAIN EARTH GROUND LOCATION ...

Page 5: ...et Board Overview ON Display Backlight Display Touch RADIO ANTENNA Connection to Control Board Door Board 1 Door Board 2 ETHERNET POWER Power Connection for Control Board Sensor Board Postal Lock Speaker Audio Dip Switches Switch 1 is used to toggle Admin Mode LOOP BOARD ...

Page 6: ...k in conjunction to control up to 4 access points INPUT OUTPUT USED FOR Wiegand Input Proximity Readers RFID Receiver and Keypads 12 Vdc Power for readers only Do not use to power external devices Request to Exit External Free Exit Loop Detectors Push Buttons and Proximity Sensors Status Door Sensors Supervised Gate Operators and EOL End of Line Wiring Primary Relay Closed Door Sensor Closed Gate ...

Page 7: ...ring tape Conduit Bender Conduit Cutter Reamer Hack Saw Center Punch Tool Hammer PROVIDED NOT SHOWN Hardware for Camera Kit Installation Manual Quickstart Guide CAPXL Carton Inventory PRE INSTALL NETWORK INSTALL ACCESS CONTROL INTRODUCTION Power Supply Goose neck Gasket Keys 2 Ferrite Core S10K30MOV Metal Oxide Varistor 4 1N4005 Diode Kit 4 Radio Antenna Security 2 0 and Cable Wi Fi Antenna and Ca...

Page 8: ...mpatibility 10 100 1 000 Ethernet Wi Fi Compatibility 802 11 a b g n Wi Fi Range Up to 500 feet 152 4 m Open Air Line of Sight range will vary depending on obstructions Built in LiftMaster Passport Receiver Security 2 0 Wireless Communication to Gate Operator Up to 750 feet 228 6 m Open Air Line of Sight range will vary depending on obstructions Compatible with LiftMaster Security 2 0 gate operato...

Page 9: ... m Postal Lock Box 2 Conductor 18 24 AWG 250 1000 feet 76 2 304 8 m NOTE Main power supply and control wiring MUST be run in separate conduits Conduits must be UL approved for low and high voltage Refer to the NEC for additional wiring requirements Category 5 cabling is the minimum performance category recommended Wiring shall be in accordance with the National Electrical Code ANSI NFPA 70 local c...

Page 10: ...ation will be required SIP service provider SIP domain SIP port usually 5060 SIP username SIP password example sip phone com example 12345 example s98hn f idjs 2 Phone Service 3 Setup a LiftMaster Cloud Account NOTE If you have an existing MyQ account your LiftMaster Cloud account will have the same password 1 If you do not have a LiftMaster Cloud Account call LiftMaster Customer Care at 800 323 2...

Page 11: ...e permanent damage 1 Turn the key clockwise to unlock the CAPXL 2 Open the door and lay the CAPXL face down on a table with the door hanging off the edge of the table as shown 3 Identify which knockouts need to be removed based on your application 4 Use a center punch tool to remove the knockouts from the outside of the box inward using an appropriately sized punch and hammer NOTE Be careful when ...

Page 12: ...nic corrosion NOTE Ensure the cover can fully open to allow access after the installation is complete Mount CAPXL 2 DO Make sure the CAPXL is properly sealed to prevent damage to the CAPXL from moisture INTRODUCTION PRE INSTALL NETWORK INSTALL ACCESS CONTROL Pedestal Mount 1 4 x 1 1 2 Ribbed Neck Security Bolt 4 Goose neck Gasket Surface Mount Recess Mount Wi Fi Antenna Security 2 0 Radio Antenna ...

Page 13: ...ommunication with LiftMaster UL325 2016 compliant gate operators 1 Remove 3 8 knockout on the side or back of the CAPXL 2 Secure the radio antenna to the desired knockout on the CAPXL 3 Connect the radio antenna cable to the Power Internet Board as shown Wi Fi Antenna if applicable Used for Wi Fi Internet 1 Remove 1 4 knockout on the side or back of the module 2 Secure the Wi Fi antenna to the des...

Page 14: ... or larger to the CAPXL main earth ground connection 2 Run the wire from the CAPXL to suitable earth ground NOTE Shield connections on boards should not be connected to main earth ground connection ON Ground wire 12 AWG minimum Earth ground rod Other ground sources within 12 feet of access control panel Ground to existing electrical system Electrical panel Ground to metallic cold water pipe 12 fee...

Page 15: ... power supply Black is negative and red is positive 2 Remove the PWR INPUT terminal block from the Power Internet Board 3 Connect the power supply wires to the PWR INPUT terminal block red to 24V and black to GND Reattach the terminal block to the Power Internet Board 4 Plug the power supply into a 120 Vac outlet after all connections have been made NOTE The green LED on the door board will blink ...

Page 16: ...the Ferrite Core 2 Loop the Input Ethernet cable around itself one time creating a loop large enough to fit over the length of the Ferrite Core Locate the cable loop near the intended electrical knock out 3 Place looped section of Input Ethernet cable over one side of the open Ferrite Core 4 Close the Ferrite Core securely and plug the Input Ethernet cable into the Power Internet board 5 Connect an...

Page 17: ...Use 18 22 AWG Power for Maglock Not Provided DO NOT use the power supply for the controller For AC Power Install a Siemens S10K30MOV Metal Oxide Varistor provided or equivalent REQUEST TO EXIT GROUND STATUS NORMALLY OPEN COMMON COMMON NORMALLY CLOSED NORMALLY CLOSED COMMON OR DOOR 1 2 3 or 4 REQUEST TO EXIT WIEGAND STATUS PRIMARY RELAY AUXILIARY RELAY GATE OPERATOR COMMON EXIT NORMALLY OPEN ALARM ...

Page 18: ... Relay Select the Outputs tab Then select the desired relay on the left hand side 1 through 4 3 Press LEARN button on gate operator Press and release the LEARN button on the primary operator The green XMITTER LED will light NOTE The operator will time out of programming mode after 180 seconds 4 Press LEARN button on gate operator again Press and release the LEARN button again on the primary operat...

Page 19: ... noise RED LED brown GREEN LED orange DATA 1 white DATA 0 green GROUND black 12Vdc red READER OR KEYPAD OR WIEGAND RFID ANTENNA with Wiegand output Power for RFID ANTENNA Not Provided DO NOT use the power supply for the controller LIGHT LOAD LINE NEUTRAL NOTE DO NOT run high voltage power within the CAPXL enclosure Isolation Relay Low Voltage Power Supply NOTE For KPR2000 keypad wire the pink and ...

Page 20: ... control boards Insulate any unused wires from the CAPXL to prevent a short Refer to instructions provided with your reader for more information 6 Reconnect power to the CAPXL 7 Refer to LiftMaster Cloud for programming INTRODUCTION PRE INSTALL NETWORK INSTALL ACCESS CONTROL Reader Reader Cover Wing Nuts Mounting Plate Mounting Holes Cable Hole Mounting Plate ON WIEGAND INPUT brown orange white gr...

Page 21: ... the resident The CAPXL will provide a LiftMaster Cloud specified facility code followed by the Directory Code of the resident that granted access And Or Successful access through Entry Code The CAPXL will provide a LiftMaster Cloud specified facility code followed by the successful Entry Code And Or Successful access with a Wiegand credential The CAPXL will pass along the successful credential Faci...

Page 22: ...e the wing nut and plug Discard the wing nut and plug 2 Remove 4 mounting nuts from studs 3 Install postal lock using 4 nuts from step 2 4 Cut the factory installed wire tie from the postal lock switch The postal lock switch is wired from the factory Postal Lock Wing Nut and Plug ...

Page 23: ...dialed 1 Secure the Loop Detector Board model LPEXP to the standoffs in the CAPXL with the provided screws 2 Connect the wire harness from the Loop Detector Board to the Power Internet Board 3 Connect the loop wires to the input on the Loop Detector Board 4 Plug in the loop detector model LOOPDETLM 5 Set both switches on the Loop Detector Board to ON auxiliary setting NOTE Loop Detector Board not ...

Page 24: ... 9 Black 10 Not used 1 2 3 4 5 6 7 8 1 Red 2 Orange 3 Yellow 4 Blue 5 Green 6 Purple 7 Not used 8 White 9 Black 10 Not used 1 2 3 4 5 6 7 8 9 10 MICROPHONE black red black white POSTAL LOCK SWITCH Wi Fi ANTENNA RADIO ANTENNA 9 10 red white green black Wiring Diagram Not responsible for conflicts between the information listed in the wiring diagram and the requirements of your local building codes ...

Page 25: ...y Reader KPR2000 Loop Detector Input Board LPEXP Cellular Modem 4G LTE CAPCELL Connected Access Portal 2 Door CAP2D CAP485 Base Station CAPB485 CAP485 Door Control CAPDC485 CAP 12 Relay Output CAPRELAY All LiftMaster MyQ UL325 compatible gate operators Passport 3 Button Visor Remote Control MAX PPV3M Passport 3 Button Mini Remote Control MAX PPK3M Passport 3 Button Mini Proximity Remote Control MA...

Page 26: ...EGAND REX STATUS EOL Y N OUTPUTS PRIMARY RELAY AUXILIARY RELAY N O N C N O N C Notes DOOR 2 DOOR GATE NAME INPUTS WIEGAND REX STATUS EOL Y N OUTPUTS PRIMARY RELAY AUXILIARY RELAY N O N C N O N C Notes DOOR 3 DOOR GATE NAME INPUTS WIEGAND REX STATUS EOL Y N OUTPUTS PRIMARY RELAY AUXILIARY RELAY N O N C N O N C Notes DOOR 4 DOOR GATE NAME INPUTS WIEGAND REX STATUS EOL Y N OUTPUTS PRIMARY RELAY AUXIL...

Page 27: ... protected by the copyright and or other intellectual property laws of the United States UL 294 Access Control Unit Endurance Level 4 Line security Level 2 Destructive Attack Level 1 Power Standby Level 1 NOTICE To comply with FCC and or Industry Canada IC rules adjustment or modifications of this digital device are prohibited THERE ARE NO USER SERVICEABLE PARTS Any changes or modifications not expr...

Page 28: ...IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE AND OF ANY OTHER OBLIGATIONS OR LIABILITY ON SELLER S PART THIS LIMITED WARRANTY DOES NOT COVER NON DEFECT DAMAGE DAMAGE CAUSED BY IMPROPER INSTALLATION OPERATION OR CARE INCLUDING BUT NOT LIMITED TO ABUSE MISUSE FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTENANCE UNAUTHORIZED REPAIRS OR ...