Screw antennas on 

TIGHT

Loose antennas will affect the signal strength!

Unlock the units and open doors.

Set both units to 

TEST MODE

.       

ONLY

 

test 2 units at a time, turn ALL other units OFF!

Set one unit to 

LOCAL connection

 and the other to 

REMOTE connection

. The 

“LOCAL 

connection” unit 

is near the telephone entry system. 

Temporarily stick the supplied battery packs on the outside of each unit with the double stick 
tape. Feed the wires through an existing hole on back of the unit. It is 

VERY

 important that 

BOTH

 

battery packs produce 12VDC, weak batteries will produce undependable test results.

Both units 

must

 be set to the same 

FACILITY FREQUENCY

. If they are not the same, 

follow 

Step

 

5

    on the manual to set the frequencies on both units.

Connect the battery wires to the removable power connector. When 

BOTH

 

units have been powered up, a 

CONTINUOUS tone

 will be heard from both 

units indicating strong signals are being transmitted 
and received.

Close and lock the units placing the 

LOCAL

 unit in 

its final position near the telephone entry system. 

Recommend minimum 8 feet above ground.

  

Take the 

REMOTE

 unit to the desired remote access 

point and place it in its final position. 
A continuous tone should be heard indicating that the range is OK. 
The units can now be 

permanently installed

 in their current 

positions. 
Use the supplied transformer for permanent power. Discard battery pack. 

Set the units back to 

OPERATING MODE

.

845 Larch Avenue Elmhurst, Illinois 60126-1196

EWC485 Range Test

2

1

3

4

5

6

7

8

9

11

10

4

5

If

 a continuous tone is not achieved after all previous suggestions have been tried,  

call for toll free technical support: 

1-800-582-2806

Stronger Signal

Less Interference

More Interference

Weak Signal

5

114A2969

Part Number 41A6082

WIR

ELES

S

com

mun

icato

r

Comp

atible

WIRELESS

communicator

Compatible

The Elite Processor MUST have this 
sticker to use the wireless communicator.
Firmware version 6.11 or later.

Make sure

 the antennas are screwed on tight.

Try

 moving the remote unit 15-20 feet in several directions, away from metal surfaces or any obstructions.

Try

 moving the local unit 15-20 feet in several directions.

Try

 raising the units up, above the rooftops if necessary to clear any obstacles. The higher the units, the 

less interference they will encounter. Keep antenna clear from metal surfaces or any obstructions that can 
weaken the signal strength.

Test

 the battery packs with a voltmeter for 12VDC. Weak batteries will produce undependable test results.

Try

 changing the 

FACILITY FREQUENCY

 of the units. Follow 

Step

 

55

  on the manual. Both units 

MUST

 be 

set to the same frequency.

If a continuous tone is

 NOT heard 

during the range test:

5

© 2004 The Chamberlain Group, Inc.

All Rights Reserved

®

Reviews: