DC Alarm Kit
K29-32410
for SL575, SL585, and SL595 Operators
Components covered
with heat shrink
Removable
connector
AC ALARM
DC ALARM
REMOVE THE EXISTING DC ALARM
1. Disconnect power from the operator.
2. Disconnect the wire harness from the main board connections
J1-16 and J1-12 (Figure 1).
NOTE:
The J1 terminal block can be removed from the main
board to aid in wiring. If you remove the terminal block, make
sure to replace it securely on the main board.
3. Remove the existing alarm and wire harness (Figure 2).
FIGURE 1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
TB2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
TB2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
J1 TERMINAL BLOCK
Red wire from alarm
Main board
Black wire from alarm
J1 TERMINAL BLOCK
Red wire (+) from alarm
Main board
Black wire (-) from alarm
Alarm
Plastic nut
Flange
Regulator
covered with
heat shrink
Operator chassis
Wire harness
Old alarm
Flange
Operator chassis
Plastic nut
CARTON INVENTORY
• Alarm with wire harness (1)
• Extra blue wire stripped on both sides (connects J1-3 to
J1-15) (1)
• Wire ties (4)
• Flange (41-G0538) (1)
TOOLS NEEDED
• Pliers
• #2 Phillips Head screwdriver
• 1/8" flat Phillips Head screwdriver
• Diagonal wire cutters
• Wire strippers
To reduce the risk of INJURY or DEATH:
• Disconnect all power BEFORE installing or servicing operator.
• See manual prior to servicing regarding maintenance and
required safety testing.
WARNING:
This product can expose you to chemicals
including lead, which are known to the State of
California to cause cancer or birth defects or other
reproductive harm. For more information go to
www.P65Warnings.ca.gov.
FIGURE 2
Existing alarm
Flange