Page 1: ...Operating and Installation Instructions CHARNWOOD GROSVENOR Bishops Way Newport Isle Of Wight PO3O 5WS U K Tel 01983 537799 Fax 01983 5377887 ...

Page 2: ...flue outlet must be correctly positioned to align with the flue outlet on the stove that you have bought Connection to the chimney the job of the installation engineer is detailed in Section 1 The stove must not be used with the door open Safety Reminders Charnwood stoves are efficient appliances giving off convected conducted and radiated heat All the surfaces of the stove except the controls are...

Page 3: ... tripping have the flue and chimney checked by your installation engineer Lighting and controlling the stove Remember that the stove is designed to be operated with the door and spinwheel securely closed 1 Near the stove will be the gas isolation tap Turn this to the on position 2 Between the front and rear legs on the right hand side of the stove you will find the burner control knob as shown in ...

Page 4: ...h a suitable glass cleaner available from your stove supplier To The Customer PLEASE READ THE FOLLOWING PROCEDURES AND SERVICE CHECKS BUT PLEASE NOTE THEY MUST ALL BE CARRIED OUT BY A QUALIFIED INSTALLA TION ENGINEER IF THE DOOR GLASS BECOMES DAMAGED OR BROKEN DO NOT USE THE STOVE Glass Replacement 1 Before carrying out the glass replacement we suggest that for safety reasons the gas supply is tur...

Page 5: ...m dust or dirt 4 Finally ensure that the thermocouple a very delicate electro mechanical device has not become damaged in any way If it is damaged a replacement pilot assembly should be obtained and fitted by your installation engineer FINAL REMINDERS We remind you that it is a legal requirement that the stove is installed by a qualified and accredited installation engineer Improper installation a...

Page 6: ...e plate the gas valve will then be neatly located through cut out in right hand side of stove body Flue Spillage Monitoring System Charnwood Grosvenor stoves are fitted with an oxygen depletion sensitive pilot Location And Recommended Hearth And Fire Opening Specification The location of Charnwood Grosvenor model stoves should have the following space around them The hearth should protrude at leas...

Page 7: ...tion The gas supply must be properly sized to provide the correct gas rate at running pressure when measured at the inlet valve The final connection to the stove must be made with a suitable 8mm dia gas pipe It is essential that a gas isolation tap is provided upstream of the stove in a position that is easily accessible Gas Pressure Make sure that there is adequate gas pressure and volume to the ...

Page 8: ...ural Gas 1st Layer below shown dotted 11 12 13 14 15 16 17 18 19 20 21 L L L L L L L L L L L ø8 0 Holes Air Tunnel Air Tunnel 1 2 3 4 5 6 7 8 9 10 Fig 3 Coal Layer 1 Natural Gas Air Tunnel S S S S S L L L L L Page 8 SV 2 00 ...

Page 9: ...s 2 3 LPG 16 17 18 19 20 21 22 23 24 25 26 1st Layer below shown dotted 3rd Layer L L L L L L L L S S S ø8 0 Holes 1 2 3 4 5 10 6 13 15 7 8 9 11 12 14 Fig 5 Coal Layer 1 LPG S S S S S L L L L L L L L L L Page 9 SV 2 00 ...