background image

 

 

 

 

 

 

 

 

 

 

 

RM133 Series   

Rackmount Chassis 

User Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

January 2020    Version 1.3 
 
 
 

A document provides an overview of product features, functions, architecture, and support specifications. 

 

Summary of Contents for RM133 Series

Page 1: ...RM133 Series Rackmount Chassis User Manual January 2020 Version 1 3 A document provides an overview of product features functions architecture and support specifications...

Page 2: ...or usage in trade This document contains information on products services and or processes in development All information provided here is subject to change without notice Contact your Chenbro represe...

Page 3: ...oval and Installation 17 2 1 Top Cover Installation 18 2 2 HDD Cage Installation 19 2 3 External Hot swap HDD Assembly Installation and Removal 20 2 4 Internal 2 5 HDD SSD Installation 25 2 5 Internal...

Page 4: ...removal 20 Figure 19 3 5 HDD installation tool less type 21 Figure 20 3 5 HDD installation screw type 21 Figure 21 2 5 HDD SSD installation screw type 22 Figure 22 2 5 hot swap HDD SSD assembly instal...

Page 5: ...val 35 Figure 45 Slide rail installation 1 84H314610 003 36 Figure 46 Slide rail installation 2 84H314610 003 36 Figure 47 Slide rail installation 3 84H314610 003 37 Figure 48 Slide rail installation...

Page 6: ...Table 5 System packaging information 16 Table 6 Product weight information 16 Table 7 Drive power LED activity LED behavior 38 Table 8 Backplane specifications 40 Table 9 Connector and pin header func...

Page 7: ...660 0 x 438 5 x 43 5 mm 25 98 x 17 26 x 1 71 Drive Bay RM13304 4 x 3 5 Hot swap 2 x 2 5 Internal 1 x Slim ODD 9 5 mm RM13310 10 x 2 5 Hot swap Storage Backplane RM13304 3 5 4 port 12Gbps SATA 7 pin RM...

Page 8: ...RM133 Series Product Overview 8 1 1 System Features Overview Figure 1 RM13304 overview Figure 2 RM13310 overview...

Page 9: ...3304 major components overview Figure 4 RM13310 major components overview A Front Top Cover B Back Top Cover C Label Embossing D Rear Top Cover Latch E Optical Drive Bay F Internal 2 5 HDD Bays G Fan...

Page 10: ...eries Product Overview 10 1 2 Front Panel Figure 5 RM13304 front panel Figure 6 RM13310 front panel A Rack Handles B Storage Drive Bay C Optical Drive Bay D Info Tag E Front Control Panel F Storage Dr...

Page 11: ...eries Product Overview 11 1 3 Back Panel Figure 7 Back panel with redundant PSU Figure 8 Back panel with single PSU A Redundant Power Supply B Single 1U Power Supply C I O Gasket D Full Height Expansi...

Page 12: ...trol panel Figure 10 RM13310 front control panel Table 2 Front control panel Label ICON Indicator button or connector A Power Button B LAN1 LAN2 Activity LED C Power LED D HDD Activity LED E System Al...

Page 13: ...RM133 Series Product Overview 13 1 5 Chassis Dimensions Figure 11 Chassis dimensions Figure 12 Label embossing dimensions...

Page 14: ...of a given rail kit or misalignment of the server in the rack may result in failure of the rack rails causing damage to the system or personal injury Two people to operate or the use of a mechanical a...

Page 15: ...2 RVI Operating HDD class Class 1 Highest performance reliability and data integrity Class 2 A second tier of performance reliability and data integrity HDD I O throughput degradation SPEC Pass Fail C...

Page 16: ...ment Table 5 System packaging information Part Number Single Bulk Form Factor mm Support Level 387 13304 3300A0 Single 840 x 595 x 170 L5 NOTE The design of the inner packaging components does not pre...

Page 17: ...ifferent storage options Up to 4 x 3 5 hot swap HDD RM13304 Up to 10 x 2 5 hot swap HDD or SSD RM13310 2 x 2 5 internal HDD or SSD up to 9 5 mm thickness RM13304 1 x Slim ODD up to 9 5 mm thickness RM...

Page 18: ...e grooves on the chassis base and slide it toward the front panel until locking into place 2 Secure the front top cover with two screws as shown Figure 14 Rear top cover installation 1 Insert the rear...

Page 19: ...gn the grooves on the cage with the pins on the chassis and slide the cage backward the front panel 2 Secure HDD cage with two screws as shown Figure 16 RM13310 HDD cage installation 1 Insert HDD cage...

Page 20: ...3 5 hot swap HDD assembly installation 1 With the lever open insert the HDD assembly into the drive bay until the end of the HDD cage 2 Push in the lever to lock it into place Figure 18 3 5 hot swap H...

Page 21: ...o place NOTE Due to degraded performance and reliability concerns the use of the 3 5 drive blank as a 2 5 device bracket is intended to support SSD type storage devices only Installing a 2 5 hard disk...

Page 22: ...5 HDD SSD installation screw type 1 Align the front of HDD SSD with the anchor point on the tray 2 Assemble 2 5 HDD SSD to the tray by three screws from the bottom as shown NOTE Dedicated screw type...

Page 23: ...installation 1 With the lever open insert the HDD SSD assembly into the drive bay until the end of the HDD SSD cage 2 Push in the lever to lock it into place Figure 23 2 5 hot swap HDD SSD assembly re...

Page 24: ...ive carriers must be installed with either drives or supplied drive blanks There are drive carriers to support 2 5 and 3 5 devices To maintain system thermal performance all drive bays must be populat...

Page 25: ...RM13304 internal 2 5 HDD installation 1 Attach the plastic carrier with the HDD and engage both embossed pins into the side dimples on the HDD as shown 2 Insert the 2 5 HDD assembly into the chassis b...

Page 26: ...stallation 26 2 5 Internal Slim ODD Installation Figure 27 Internal slim ODD installation 1 Insert the slim ODD with an angle as shown Ensure two embossed pins and side dimples engaged 2 Carefully pus...

Page 27: ...screw type 1 Push the system all the way into the cabinet 2 Secure the system with two thumb screws clockwise on both sides Figure 29 Installation of whole system into the rack latch type 1 Push the...

Page 28: ...tach the fan guard with fan as shown and secure it with two screws 2 Insert four fan mounts as shown Figure 31 Fan module installation 4028 1 Attach the fan bracket with the chassis bottom and secure...

Page 29: ...and secure it with two screws 2 Attach plastic extension holder with the fan 3 Insert four fan mounts as shown Figure 33 Fan module installation 4048 1 Attach the fan bracket with chassis bottom and...

Page 30: ...and secure it with two screws 2 Attach plastic extension holder with the fan 3 Insert four fan mounts as shown Figure 35 Fan module installation 4056 1 Attach the fan bracket with chassis bottom and...

Page 31: ...guard with fan as shown and secure it with two screws 2 Insert four fan mounts as shown Figure 37 Fan module installation 4056 1 Attach the fan bracket with chassis bottom and secure it with four scr...

Page 32: ...RM133 Series System Components Removal and Installation 32 Figure 38 Air baffle installation 1 Insert the air baffle into the fan guard as shown until its tabs locking into place...

Page 33: ...Remove the PCIe blank Figure 40 Cards and brackets installation 2 Secure the riser card with PCIe bracket by two screws 3 Align two screw holes of PCIe slot bracket with the PCIe card and secure them...

Page 34: ...ion and Removal Figure 41 Single 1U PSU installation 1 Figure 42 Single 1U PSU installation 2 1 Secure the PSU bracket with two screws as shown 2 Secure the PSU bracket with another two screws from th...

Page 35: ...igure 43 Redundant PSU module installation 1 Insert the PSU module into the PSU cage and push it until clicking into place Figure 44 Redundant PSU module removal 1 Press the latch and release the PSU...

Page 36: ...tion Figure 45 Slide rail installation 1 84H314610 003 1 Attach the inner rail to the chassis base while aligning T pins on the side of the system with the slots on the inner rail Figure 46 Slide rail...

Page 37: ...s Removal and Installation 37 Figure 47 Slide rail installation 3 84H314610 003 3 Lift the latch as shown 4 Secure the inner rail with one screw Figure 48 Slide rail installation 4 84H314610 003 5 Ins...

Page 38: ...CON LED Color Behavior Condition A C Power LED N A Stay off Fault Blue Solid on Present B D Activity LED Green Solid on Access Red Solid on Failure 1Hz blink Rebuild 4Hz blink Locate NOTE The drive ac...

Page 39: ...on features 12Gbps SAS 6Gbps SAS SATA and PCIe Gen3 x 4 NVMe SFF 8680 12Gbps rated drive interface connectors providing both power and I O signals to attached devices SFF 8639 PCIe Gen3 x 4 rated driv...

Page 40: ...splay LED indicates storage device status Power LED Off Fault Blue on Present Access LED Green on Access Red on Failure Red 1Hz blink Rebuild Red 4Hz blink Locate Environment Monitor NA Connectors 1 4...

Page 41: ...the backplane Power is routed to the backplane via a power cable harness from the power supply B SATA 7 pin The backplane includes four SATA 7 pin connectors providing data signals for four SAS SATA d...

Page 42: ...wer LED Off Fault Blue on Present Activity LED Green on Access Red on Failure Red 1Hz blink Rebuild Red 4Hz blink Locate Environment Monitor Temperature senor TMP75 detection U3 Connectors 1 10 x SFF...

Page 43: ...Power is routed to the backplane via a power cable harness from the power supply B Mini SAS HD The backplane includes three multi ports Mini SAS HD cable connectors providing data signals for ten SAS...

Page 44: ...ff Fault Blue on Present Activity LED Green on Access Red on Failure Red 1Hz blink Rebuild Red 4Hz blink Locate Environment Monitor Temperature senor TMP75 detection U3 Connectors 1 10 x SFF 8639 2 10...

Page 45: ...ackplane includes ten OCuLink connectors providing data signals for ten NVMe drives on the backplane A cable can be routed from matching connectors on the server board or add in PCIe switch cards C I2...

Page 46: ...ht to examine the DOA products If the damage of DOA products is caused by improper action as described above the customer will be liable for paying the related charge having occurred or paying the fee...