Infrared thermometer
User's Manual
1. SUMMARY OF INFRARED THERMOMETER
Thank you very much for choosing our Infrared thermometer. It is a high technology medical ther
-
mometer for measuring eardrum and forehead temperature of human body via infrared rays emitted
from the eardrum and skin surface, which will allow you to learn you and your family’s health status
easily and quickly. A corrected way to measure is very important to obtain the precise temperature. To
ensure proper use, please be sure to read this user manual carefully.
t
To ensure proper use, please be sure to read this user manual carefully, paying close attention to the
safety precautions.
t
Please keep the instructions handy for reference.
2. SAFETY PRECAUTIONS
Warning
Conducting self-diagnosis and/ or treatment based on the measurement results can be dangerous.
Be sure to follow the instruction of your doctor.
t
Self-diagnosis may worsen the symptoms.
If the infrared sensor becomes dirty, lightly wipe it with a soft dry cloth.
t
If you wipe it with a tissue paper or a paper towel, the infrared sensor will be damaged and may be
able to measure correctly.
The patient who su
ff
er the external otitis and media otitis or other ear diease that will be prohibited to
using the product to measure ear temperature.
t
It may worsen the lesion.
Do not touch the infrared sensor with
fi
nger or breathe on it.
t
The infrared sensor may become dirty and correct measurement result may not be possible.
Store the unit out of children’s reach.
t
Children may try to measure by themselves and cause damage to the ear. If a child accidentally
swallows a battery or other component, immediately consult with the doctor.
If there is a di
ff
erence in temperature between the place where the unit is stored and the place where
your are going to measure, leave the unit in the room where you are going to use form more than
thirty minutes, then measure.
t
Correct measurement result may not be possible.
Don’t throw the battery into
fi
re.
t
May be cause the battery explosion.
Notice
Do not forcibly insert the probe in the ear. If you fell abnormal such as pain during measurement, stop
using the unit.
t
It may injure the external auditory canal.
If the ear is cooled such as being exposed to the cold for a long period, wait until the ear is warmed
up, then measure.
t
The measured result may be indicated low when you an ice bag or immediately after coming
home from outside in winter.
Do not use the unit when the external auditory canal is wet such as after swimming or a bath.
t
It may cause measurement inaccurate.
When you inform the doctor of your temperature, make sure to tell him/ her that you measured the
temperature in the ear.
Do not measure the sites of scarred tissue or tissue compromised by skin disorders, because sensing
body temperature from sites of scarred tissue or tissue compromised by skin disorders.
Do not measure the site of forehead temperature if that patients has trauma on forehead.
Do not measure when the measured sites (forehead) is exposed to direct sunlight,
fi
replace heat, cold
compress therapies, air conditioner
fl
ow. If you are under these cases, please leave the status and wait
for 30 minutes to measure.
Do not apply strong shock to, drop, step on, or vibrate the main unit.
Do not use a portable phone near the unit.
Do not disassemble, repair, or modify the unit.
After you do some exercise, eating and bathing, you should stay still indoor about 30 minutes before
measurement.
The thermometer maintenance improper or improper use will cause harm to human body and the
component aging function will cause function loss.
The main unit is not waterproof. Be sure that no liquids (alcohol, water, or hot water) get into the main
unit.
To make the measurement data reliable and stable, when ambient temperature varies a lot, the
thermometer should be placed indoors for about 30 minutes before using.
When we measure somebody continuously, the temperature should be measured every minute, if
you need to measure yourself Continuously for a short time, there are some slight errors when you
read the temperature ,which is a normal phenomenon. At this time, we should choose the average.
We recommend that you measure yourself continuously maximum of three in a unit of time, and
because the temperature of the human will conduct to the thermometer, it may a
ff
ect the accuracy
of measurement.
There is no absolute standard about the temperature of the human, so please try to collect the
recording of Individual temperature in the usual, as a reference for having a fever or not.
Do not measure if that patient is treated with certain drug therapies.
In order to ensure the accuracy of measurement data, please don’t take measurement of body
temperature in strong electromagnetic interference environment (such as microwave, high frequency
equipment operation environment).
Recommendation
Don’t use this thermometer for other purposes.
It is forbidden to leave the product exposed to any chemical solvent, direct sunshine or high
temperature.
3. INTENDED USE
Except for measurement of ear and forehead temperature, don’t use this product for other purposes. It
can be used for anybody, e.g. for new-born, for children and for adults.
For the safety reason, children or the baby’s body temperature must be measured by parent or adults.
WARNING:
Do not let a child or baby use the thermometer.
It must always be operated by an adult.
4. TEMPERATURE MEASUREMENT MODE AND RANGE DESCRIPTION
The infrared thermometer has the following measurement mode:
1) Forehead temperature measurement mode -- measure the skin surface of human forehead’s
temperature accurately, take the place of traditional mercury thermometer and electrical
thermometer.
2) Eardrum temperature measurement mode—measure the skin surface of human eardrum’s
temperature accurately, take the place of traditional mercury thermometer and electrical
thermometer
Normal temperature range for di
ff
erent measuring position
Measuring position
Normal temperature (°C)
Normal temperature (°F)
Anus
36.6-38.0
97.9-100.4
Oral
35.5-37.5
95.9-99.5
Armpit
34.7-37.3
94.5-99.1
Ear
35.5-37.8
95.9-100
Forehead
35.8-38.0
96.4-100.4
Age Range
Normal temperature (°C)
Normal temperature (°F)
0-2 years old
36.4-38.0
97.5-100.4
3-10 years old
36.1-37.8
97.0-100.0
11-65 years old
35.9-37.6
96.6-99.7
>
65 years old
35.8-37.5
96.4-99.5
NOTE: The normal temperature and di
ff
erence between the di
ff
erent body parts is individual. To
de
fi
ne you, measure your temperature for a least 2 weeks at the same ear cannal, forehead
position and time.
NOTE: When consulting your physician, communicate which positon that the
thermometer is measured, note the individual’s normal infrared reading as above when
comparing.
NOTE: Because the forehead temperature is a
ff
ected obviously by the external environment(eg:
environment, air convection and skin tone, etc),we advice that you take the forehead
temperature only as reference. When you have a doubt about the measurement result, please
use the ear temperature to con
fi
rm it.
5. FEATURE
Functional diversity
5-in-1 unique design can take ear/ forehead/ object temperature/ ambient temperature and clock with
a clock display, i.e.
fi
ve-in-one.
Instant measurement it provides you the reading in one second.
This product has passed the European Union and Chinese the infrared thermometer performance
standards for measuring clinical requirements, measuring clinical repeatability is no more than ±0.3°C.
Convenient and cheap
Convenient, economic, probe cover free and easy to use.
Simple to use
Automatically converts forehead temperature display into ear temperature display with the removal of
the front cover. Simple to use
High body temperature indicator
Beep-”for a long one followed by two short ones, and the
icon will go on .
A wide range of temperature
Body measurement mode: the measurement range: 32°C-42.9°C.
Object temperature measurement mode: the measurement rang: 0°C-100°C.
Automatic display of memory.
Every time you turn it on, the previous reading will be shown.
6. OVERALL DESCRIPTION
Main component including
LCD display description
Temperature value
Measuring in progress
Object temperature mode
Ear Scan Mode
Forehead Scan Mode
High body temperature symbol
Temperature unit : °C or °F
Clock mode symbol
Low battery indication icon
Last Memorized Temperature Display
7. OPERATION INSTRUCTION
【
Preparation
】
1) Check battery
Replace the batteries to ensure power supply if there is low voltage icon for the thermometer.
2) Check thermometer
When you press the “ ” button, the system will have self testing of software and hardware. If there
are problems, LCD will display "Err" symbol.
3) In order to make the accurate measuring result, put the thermometer in the measurement environment
for 30 minutes.
test temperature in front of the air conditioner, it will not be able to obtain accurate results.
5) If you want measure forehead temperature, clean forehead and arrange hair, make sure the forehead is
naked and clean, in order to ensure the accuracy of measurement; If you want measure ear temperature,
clean subject ear cannel, make sure the ear is clean.
【
Time and Ambient Temperature
】
Set the when you use the device for the
fi
rst time or when you reinstall the battery. Then, the function
of displaying the environmental temperature and time will automatically start up.
1. Method of setting
Open the battery cap on the back, press the [Time Setting] button to start hour (hour number
fl
ashes)
and minute(minute number
fl
ashes) setting, and Press the button of scan to adjust the numbers.
2. Mode of display
When time has been set, the thermometer will display the time and environmental temperature in
turns while not used to measure body temperature.
【
Instruction for use
】
Taking Temperature in Ear Temperature Mode
1. When the system is in the state of time/environmental temperature display, press the
button of scan, and the last temperature measurement will be displayed; then after
“Beep-Beep”,the system enters into the mode of measurement.
2. Remove the forehead cap, and the thermometer enters into the ear measuring mode.
3. When measuring ear temperature, insert the probe into the ear
fi
rst, then press
the [Scan] button. One second later you will hear “Beep”, and you can remove the
thermometer. The measurement is completed.
4. When the measured temperature exceeds 38.0°C(100.4°F) , the thermometer will send
out “Beep-Beep-Beep-” a long one and two short ones, and the display will show the
icon of fever.
NOTE:
1. Keep the probe surface clean, otherwise the measurement can’t be accurate.
2. Clean the probe with clean cloth or paper moistened with water or alcohol, and conduct measurement
after the water on the surface of the probe all evaporates.
TEMPERATURE TAKING HINTS
t
The right ear temperature may di
ff
er from the left ear. Therefore, always take the
temperature in the same ear.
t
The ear must be free from obstruction or excess earwax build-up to take an accurate reading.
t
External factors may
ear temperatures, including when an individual has:
-
been lying on one ear or the other
-
had their ears covered
-
been exposed to very hot or very cold temperatures, or
-
been recently swimming or bathing.
In these cases, remove the individual from the situation and wait 30 minutes prior to taking a tem-
perature.
t
Use the untreated ear if prescription ear drops or other ear medications have been placed in
the ear canal.
t
Don’t use the thermometer outdoors.
Taking Temperature in Forehead Temperature Mode
1. When the system is in the state of time environmental temperature display, press the [Scan] button and
the last temperature reading will be displayed. Then, the system will go “Beep-Beep” and enter into the
mode of measurement.
2. Make sure the forehead cap is on, and press the button of scan directly to measure the forehead tem
-
perature.
3. When measuring the forehead temperature, keep pressing the button of scan, put the tip of the probe on
your forehead, be sure the correct temperature has been taken, then release the button of scan, you can
get the result.
4. When the measured temperature exceeds 38.0°C(100.4°F), the thermometer will send out “Beep—Beep-
Beep”, a long one and two short ones, and the display will show the icon of fever.
TEMPERATURE TAKING HINTS
t
Before take the temperature, please the forehead hair to prevent measured deviation.
t
The sweat on head or cosmetic can
the accuracy of measurement, please maintain
the cleanness of the forehead when measuring.
t
It is normal that there may be temperature
depending on various skin types and
color, since
skin type will
voltage of infrared ray.
t
Don’t use the thermometer outdoors.
【
Taking Temperature in Object Temperature Mode
】
In the mode of shutdown, keep press the [Power/Scan] button until the “” showing on the LCD, at
this time you into the object temperature mode.
Object mode can’t transform to ear and forehead temperature mode by hand. It will be automatic
shutdown in 30 seconds.
TEMPERATURE TAKING HINTS
t
For heat-insulated object, please don’t measure the surface.
t
For the hot liquid, please do not directly measure the surface, because the hot steam fog can
condense in the sensor lens and cause the measurement deviation.
【
The Measurement Unit
】
The infrared thermometer can display temperature measurements in °C only.
Thank you for choosing the Cherub Baby 4 in 1 Ear and Forehead Thermometer. The high technology
thermometer is perfect for measuring the eardrum and forehead temperature of babies all the way
through to adults. It’s very important you please read the instructions from start to
fi
nish to ensure you
are measuring the temperature the correct way and getting the correct reading.
We hope you enjoy your 4 in 1 Ear and Forehead thermometer. To
fi
nd more Cherub Baby
products be sure to visit the Cherub Baby website for your country or refer to the parent
website www.cherubbaby.com.au