1.  SUMMARY OF INFRARED THERMOMETER

Thank you very much for choosing our Infrared thermometer. It is a high technology medical ther

-

mometer for measuring eardrum and forehead temperature of human body via infrared rays emitted 

from the eardrum and skin surface, which will allow you to learn you and your family’s health status 

easily and quickly. A corrected way to measure is very important to obtain the precise temperature. To 

ensure proper use, please be sure to read this user manual carefully.

t

  To ensure proper use, please be sure to read this user manual carefully, paying close attention to the 

safety precautions.

t

  Please keep the instructions handy for reference.

2.  SAFETY PRECAUTIONS

Warning 

Conducting self-diagnosis and/ or treatment based on the measurement results can be dangerous. 

Be sure to follow the instruction of your doctor.

t

  Self-diagnosis may worsen the symptoms.

If the infrared sensor becomes dirty, lightly wipe it with a soft dry cloth.

t

  If you wipe it with a tissue paper or a paper towel, the infrared sensor will be damaged and may be 

able to measure correctly.

The patient who su

ff

er the external otitis and media otitis or other ear diease that will be prohibited to 

using the product to measure ear temperature.

t

  It may worsen the lesion.

Do not touch the infrared sensor with 

fi

nger or breathe on it.

t

  The infrared sensor may become dirty and correct measurement result may not be possible.

Store the unit out of children’s reach.

t

  Children may try to measure by themselves and cause damage to the ear. If a child accidentally 

swallows a battery or other component, immediately consult with the doctor.

If there is a di

ff

erence in temperature between the place where the unit is stored and the place where 

your are going to measure, leave the unit in the room where you are going to use form more than 

thirty minutes, then measure.

t

  Correct measurement result may not be possible.

Don’t throw the battery into 

fi

re.

t

  May be cause the battery explosion.

Notice 

Do not forcibly insert the probe in the ear. If you fell abnormal such as pain during measurement, stop 

using the unit.

t

  It may injure the external auditory canal.

If the ear is cooled such as being exposed to the cold for a long period, wait until the ear is warmed 

up, then measure.

t

  The measured result may be indicated low when you an ice bag or immediately after coming 

home from outside in winter.

Do not use the unit when the external auditory canal is wet such as after swimming or a bath.

t

  It may cause measurement inaccurate.

When you inform the doctor of your temperature, make sure to tell him/ her that you measured the 

temperature in the ear.
Do not measure the sites of scarred tissue or tissue compromised by skin disorders, because sensing 

body temperature from sites of scarred tissue or tissue compromised by skin disorders.
Do not measure the site of forehead temperature if that patients has trauma on forehead.
Do not measure when the measured sites (forehead) is exposed to direct sunlight, 

fi

replace heat, cold 

compress therapies, air conditioner 

fl

ow. If you are under these cases, please leave the status and wait 

for 30 minutes to measure.
Do not apply strong shock to, drop, step on, or vibrate the main unit.  

Do not use a portable phone near the unit.

Do not disassemble, repair, or modify the unit.
After you do some exercise, eating and bathing, you should stay still indoor about 30 minutes before 

measurement.
The thermometer maintenance improper or improper use will cause harm to human body and the 

component aging function will cause function loss.
The main unit is not waterproof. Be sure that no liquids (alcohol, water, or hot water) get into the main 

unit.
To make the measurement data reliable and stable, when ambient temperature varies a lot, the 

thermometer should be placed indoors for about 30 minutes before using.
When we measure somebody continuously, the temperature should be measured every minute, if 

you need to measure yourself Continuously for a short time, there are some slight errors when you 

read the temperature ,which is a normal phenomenon. At this time, we should choose the average. 

We recommend that you measure yourself continuously maximum of three in a unit of time, and 

because the temperature of the human will conduct to the thermometer, it may a

ff

ect the accuracy 

of measurement.
There is no absolute standard about the temperature of the human, so please try to collect the 

recording of Individual temperature in the usual, as a reference for having a fever or not.
Do not measure if that patient is treated with certain drug therapies.
In order to ensure the accuracy of measurement data, please don’t take measurement of body 

temperature in strong electromagnetic interference environment (such as microwave, high frequency 

equipment operation environment).

Recommendation  

Don’t use this thermometer for other purposes.
It is forbidden to leave the product exposed to any chemical solvent, direct sunshine or high 

temperature.

3. INTENDED USE

Except for measurement of ear and forehead temperature, don’t use this product for other purposes. It 

can be used for anybody, e.g. for new-born, for children and for adults.

For the safety reason, children or the baby’s body temperature must be measured by parent or adults. 

WARNING:

 Do not let a child or baby use the thermometer. 

                        It must always be operated by an adult.

4. TEMPERATURE MEASUREMENT MODE AND RANGE DESCRIPTION

The infrared thermometer has the following measurement mode:

1)  Forehead temperature measurement mode -- measure the skin surface of human forehead’s 

temperature accurately, take the place of traditional mercury thermometer and electrical 

thermometer.

2)  Eardrum temperature measurement mode—measure the skin surface of human eardrum’s 

temperature accurately, take the place of traditional mercury thermometer and electrical 

thermometer

Normal temperature range for di

ff

erent measuring position

Measuring position

Normal temperature (°C)

Normal temperature (°F)

Anus

36.6-38.0

97.9-100.4

Oral

35.5-37.5

95.9-99.5

Armpit

34.7-37.3

94.5-99.1

Ear

35.5-37.8

95.9-100

Forehead

35.8-38.0

96.4-100.4

Age Range

Normal temperature (°C)

Normal temperature (°F)

0-2 years old

36.4-38.0

97.5-100.4

3-10 years old

36.1-37.8

97.0-100.0

11-65 years old

35.9-37.6

96.6-99.7

65 years old

35.8-37.5

96.4-99.5

NOTE:  The normal temperature and di

ff

erence between the di

ff

erent body parts is individual. To

de

fi

ne you, measure your temperature for a least 2 weeks at the same ear cannal, forehead 

position and time.

NOTE: When consulting your physician, communicate which positon that the 

thermometer is measured, note the individual’s normal infrared reading as above when

comparing.

NOTE:  Because the forehead temperature is a

ff

ected obviously by the external environment(eg: 

environment, air convection and skin tone, etc),we advice that you take the forehead 

temperature only as reference. When you have a doubt about the measurement result, please 

use the ear temperature to con

fi

rm it.

5. FEATURE

Functional diversity

5-in-1 unique design can take ear/ forehead/ object temperature/ ambient temperature and clock with 

a clock display, i.e. 

fi

ve-in-one.

Instant measurement it provides you the reading in one second.

This product has passed the European Union and Chinese the infrared thermometer performance 

standards for measuring clinical requirements, measuring clinical repeatability is no more than ±0.3°C.

Convenient and cheap

Convenient, economic, probe cover free and easy to use.

Simple to use

Automatically converts forehead temperature display into ear temperature display with the removal of 

the front cover. Simple to use

High body temperature indicator 

Beep-”for a long one followed by two short ones, and the 

 

 icon will go on .

A wide range of temperature

Body measurement mode: the measurement range: 32°C-42.9°C.

Object temperature measurement mode: the measurement rang: 0°C-100°C.

Automatic display of memory.

Every time you turn it on, the previous reading will be shown.

6.   OVERALL DESCRIPTION

Main component including

LCD display description

Temperature value

Measuring in progress

Object temperature mode 

Ear Scan Mode

Forehead Scan Mode

High body temperature symbol

Temperature unit : °C or °F

Clock mode symbol  

Low battery indication icon

Last Memorized Temperature Display

7.  OPERATION INSTRUCTION

Preparation

 

1)  Check battery 

Replace the batteries to ensure power supply if there is low voltage icon for the thermometer.

2)  Check thermometer

When you press the “   ” button, the system will have self testing of software and hardware. If there 

are problems, LCD will display "Err" symbol. 

3)   In order to make the accurate measuring result, put the thermometer in the measurement environment 

for 30 minutes.

test temperature in front of the air conditioner, it will not be able to obtain accurate results.

5)  If you want measure forehead temperature, clean forehead and arrange hair, make sure the forehead is 

naked and clean, in order to ensure the accuracy of measurement; If you want measure ear temperature, 

clean subject ear cannel, make sure the ear is clean.

Time and Ambient Temperature

Set the when you use the device for the 

fi

rst time or when you reinstall the battery. Then, the function 

of displaying the environmental temperature and time will automatically start up. 

1. Method of setting

Open the battery cap on the back, press the [Time Setting] button to start hour (hour number 

fl

ashes) 

and minute(minute number 

fl

ashes) setting, and Press the button of scan to adjust the numbers. 

2. Mode of display

When time has been set, the thermometer will display the time and environmental temperature in 

turns while not used to measure body temperature. 

Instruction for use

Taking Temperature in Ear Temperature Mode

1.   When the system is in the state of time/environmental temperature display, press the 

button of scan, and the last temperature measurement will be displayed; then after 

“Beep-Beep”,the system enters into the mode of measurement.

2.  Remove the forehead cap, and the thermometer enters into the ear measuring mode. 

3.   When measuring ear temperature, insert the probe into the ear 

fi

rst, then press 

the [Scan] button. One second later you will hear “Beep”, and you can remove the 

thermometer. The measurement is completed.

4.   When the measured temperature exceeds 38.0°C(100.4°F) , the thermometer will send 

out “Beep-Beep-Beep-” a long one and two short ones, and the display will show the 

icon of fever.

NOTE: 

1.    Keep the probe surface clean, otherwise the measurement can’t be accurate.

2.   Clean the probe with clean cloth or paper moistened with water or alcohol, and conduct measurement 

after the water on the surface of the probe all evaporates.

TEMPERATURE TAKING HINTS

t

  The right ear temperature may di

ff

er from the left ear. Therefore, always take the 

temperature in the same ear.

t

  The ear must be free from obstruction or excess earwax build-up to take an accurate reading.

t

  External factors may 

 ear temperatures, including when an individual has:

 

been lying on one ear or the other

 

had their ears covered

 

been exposed to very hot or very cold temperatures, or

 

been recently swimming or bathing. 

 

 

 

 

 

In these cases, remove the individual from the situation and wait 30 minutes prior to taking a tem-

perature.

t

  Use the untreated ear if prescription ear drops or other ear medications have been placed in 

the ear canal.

t

  Don’t use the thermometer outdoors.

Taking Temperature in Forehead Temperature Mode

1.   When the system is in the state of time environmental temperature display, press the [Scan] button and 

the last temperature reading will be displayed. Then, the system will go “Beep-Beep” and enter into the 

mode of measurement.

2.   Make sure the forehead cap is on, and press the button of scan  directly to measure the forehead tem

-

perature.

3.   When measuring the forehead temperature, keep pressing the button of scan, put the tip of the probe on 

your forehead, be sure the correct temperature has been taken, then release the button of scan, you can 

get the result.

4.   When the measured temperature exceeds 38.0°C(100.4°F), the thermometer will send out “Beep—Beep-

Beep”, a long one and two short ones, and the display will show the icon of fever.

TEMPERATURE TAKING HINTS

t

  Before take the temperature, please   the forehead hair to prevent measured deviation.

t

  The sweat on head or cosmetic can 

 the accuracy of measurement, please maintain 

the cleanness of the forehead when measuring.

t

  It is normal that there may be temperature 

 depending on various skin types and 

color, since 

 skin type will 

 

 voltage of infrared ray.

t

  Don’t use the thermometer outdoors.

Taking Temperature in Object Temperature Mode

In the mode of shutdown, keep press the [Power/Scan] button until the “” showing on the LCD, at 

this time you into the object temperature mode. 

Object mode can’t transform to ear and forehead temperature mode by hand. It will be automatic 

shutdown in 30 seconds.

TEMPERATURE TAKING HINTS

t

  For heat-insulated object, please don’t measure the surface.

t

  For the hot liquid, please do not directly measure the surface, because the hot steam fog can 

condense in the sensor lens and cause the measurement deviation.

The Measurement Unit

The infrared thermometer can display temperature measurements in °C only. 

Thank you for choosing the Cherub Baby 4 in 1 Ear and Forehead Thermometer. The high technology 

thermometer is perfect for measuring the eardrum and forehead temperature of babies all the way 

through to adults.  It’s very  important you please read the instructions from start to 

fi

nish to ensure you 

are measuring the temperature the correct way and getting the correct reading.

We hope you enjoy your 4 in 1 Ear and Forehead thermometer. To 

fi

nd more Cherub Baby

products be sure to visit the Cherub Baby website for your country or refer to the parent

website www.cherubbaby.com.au

Reviews: