CHIEF MANUFACTURING INC. 1-800-582-6480, Fax: 1-877-894-6918, Email: chief@chiefmfg.com
CMA-300
PIPE
CLAMP
ADAPTER
FOR
SUPPORTING
1
½”NPT
PIPE
COLUMN
Unpack carton and check contents:
(1)
Pipe Clamp Adapter
(2) 5/16-18 x 3 ¼” Hx.Soc.Hd.Cp. Screw
(2)
5/16-18 x 1 ¼” Hx.Soc.Hd.Cp. Screw
(2) 5/16-18 x 4 ¼” Hx.Soc.Hd.Cp. Screw
(2)
5/16-18 x 2 ¼” Hx.Soc.Hd.Cp. Screw
(1) Set Screw
(4)
5/16-18
Nylock
Nuts
(1)
Allen
Wrench,
5/32”
(4)
¼”
Washer,
Flat,
Black
(1)
Allen
Wrench
¼”
CAUTION! The overhead support must be capable of supporting five times the
weight of the mount and equipment combined. If it cannot is MUST be
reinforced.
I
NSTALLATION
I
NSTRUCTIONS
1.
Slide right bracket and left bracket back and forth by lososening 5/16-18 Nylock nuts. Note! 1 ½” NPT nipple
faces down.
2.
Determine pipe diameter, 1.9 to 3.5 maximum. Spread clamp open to dimension required, allow for clearance when
installing.
3.
Slide clamp together around pipe, install 5/16-18 hex socket head cap screws above and below pipe and through
clamp, secure with nylock nuts and tighten moderately.
4.
Tighten four 5/16-18 Nylock nuts in slotted holes.
5.
Once clamp is secure, 1 ½”NPT, pipe column can be threaded into nipple.
Adjustments:
Pitch: Slight pitch adjustment can be made by loosening cap screws at pipe clamp retighten as required to secure at desired angle.
Yaw: Turn pipe assembly in nipple at initial install to achieve desired orientation. Secure with set screw.