I N S T A L L A T I O N   I N S T R U C T I O N S

WITH TS118

WITH TS218

THINSTALL™ IN-WALL ENCLOSURE

Spanish Product Description

German Product Description

 Portuguese Product Description

 Italian Product Description

Dutch Product Description

French Product Description

TA502

Summary of Contents for Thinstall TA502

Page 1: ...U C T I O N S WITH TS118 WITH TS218 THINSTALL IN WALL ENCLOSURE Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description TA502 ...

Page 2: ...to which this component is attached can support five times the combined weight of all equipment Reinforce the structure as required before installing the component The wall to which the mount is being attached may have a maximum drywall thickness of 5 8 1 6cm WARNING Exceeding the weight capacity can result in serious personal injury or damage to equipment It is the installer s responsibility to m...

Page 3: ...LL BOX WITH TS218 FULLY RETRACTED MONITOR WILL BE FLUSH WITH WALL FULLY EXTENDED MONITOR WILL BE 16 55 FROM WALL MAX TILT IS 12 DEGREES 18 85 478 8 GROUNDING GROUNDING TRIM NOT SHOWN USE THESE DIMENSIONS FOR CUTOUT NOTES ELECTRICAL KNOCK OUTS 1 SINGLE GANG RACO 590 STEEL CITY CY 1 2 OR SIMILAR STYLE ELECTRICAL BOX 1 AND 2 TRADE PIPE CONDUIT PRODUCT WORKS WITH TS118 AND TS218 2 DIMENSIONS INCHES MI...

Page 4: ... ARM SMALL BOX WITH TS118 FULLY RETRACTED MONITOR WILL BE FLUSH WITH WALL FULLY EXTENDED MONITOR WILL BE 16 55 FROM WALL MAX TILT IS 12 DEGREES 14 25 362 0 SWING ARM SMALL BOX WITH TS218 FULLY RETRACTED MONITOR WILL BE FLUSH WITH WALL FULLY EXTENDED MONITOR WILL BE 16 55 FROM WALL MAX TILT IS 12 DEGREES ...

Page 5: ...esserrez les fixations Phillips Screwdriver Destornillador Phillips Kreuzschlitzschraubendreher Chave de fendas Phillips Cacciavite a stella Kruiskopschroevendraaier Tournevis à pointe cruciforme Pencil Mark Marcar con lápiz Stiftmarkierung Marcar com lápis Segno a matita Potloodmerkteken Marquage au crayon Drill Hole Perforar Bohrloch Fazer furo Praticare un foro Gat boren Percez un trou Hex Head...

Page 6: ...if needed for installing electrical box F 1 M4 Allen driver bit G 4 2 long 2 short Trim pieces K 16 Tape squares H 4 Cable tie mounts J 12 5 1 2 cable tie L 4 9 16 Grounding screw and washer installed at factory Earthing symbol IEC 60417 No 5019 affixed adjacent to grounding terminal A 1 TA502 M 4 5 16 18 x 1 2 N 3 1 4 20 x 1 2 P 1 attach bracket ...

Page 7: ... cutting drilling or installing fasteners 2 Using a stud sensor locate and mark studs 3 Center and level housing between marked studs 4 Using housing as a template draw pencil line completely around housing NOTE Housing is designed to fit between and directly against two adjacent wall studs See Figure 1 5 Cut drywall on outside edge of line and remove Frame Housing IMPORTANT Consult a qualified bu...

Page 8: ...ll four 3 16 diameter pilot holes in studs at side mounting holes See Figure 3 7 Attach the TA502 A using four M7 x 50mm Allen head connector screws D and four spacers B into pilot holes using an M4 Allen head drill bit F See Figure 4 NOTE The TA502 has 1 2 total clearance between the two studs The spacers allow side to side adjustment Figure 4 8 Drill four 3 16 diameter pilot holes in horizontal ...

Page 9: ...esponding hole on attach bracket P leaving screw hanging out 1 4 from bracket See Figure or See Figure 9 3 Hang TS118 218SU mount onto screw by latching key shaped hole over screw See Figure or See Figure 9 Figure 8 Figure 9 4 Use one TS118SU or two TS218SU 1 4 20 x 1 2 button head cap screws N to attach TS118 218SU to attach bracket P See Figure 10 and See Figure 11 5 Tighten all screws to secure...

Page 10: ...lange of each trim piece G See Figure 12 2 Orient trim pieces G See Figure 12 3 Remove paper covering adhesive back from tape squares K on trim and press trim G against inner wall of box See Figure 12 Figure 12 Cable Management 1 Attach all cables to display 2 If necessary use cable tie mounts H and cable ties J to secure cables within TA502 TS218SU N x 2 4 5 TS218SU install G x 4 3 K x 16 1 TS118...

Page 11: ...Installation Instructions TA502 11 ...

Page 12: ...com 10 15 USA International A 6436 City West Parkway Eden Prairie MN 55344 P 800 582 6480 952 225 6000 F 877 894 6918 952 894 6918 Europe A Franklinstraat 14 6003 DK Weert Netherlands P 31 0 495 580 852 F 31 0 495 580 845 Asia Pacific A Office No 918 on 9 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong P 852 2145 4099 F 852 2145 4477 ...