USB/RS-485/RS-422
BF-850 CONVERTER USER MANUAL
I
、
FOREWORD
Developing by PC industry, USB interface
replacing many kind of old PC interface step by
step. However, many types of important
equipment still use RS-422/RS-485 interface, in
order to transfer the data between PC and
RS-422/RS-485 interface. That’s why we need
to use USB/RS-422/485 converter.
BF-850 is a converter in common use; it
does not need extra power. It also conforms to
the standard of USB, RS-422 and PR-485, and
be able to transfer USB signal to RS-422 or
RS-485 signal. There has no delay automatic
transfer inside, the unique I/O electric
auto-control the direction of data transfer, and
need no handshake signal (like RTS, ETR) to
transfer with full duplex (RS-422) and half duplex
(RS-485).
BF-850 can provide the reliable connection
between point to point and point to multi-points.
In point to multi-points each converter can
connects 32 units of RS-422 or RS-485 interface
equipment. The speed of data transfer is
300~921600 bps and the communication types
are USB to RS-422, USB to RS-485.
II
、
Property argument
1. Standard
:
Conform to the standard of USB
V1.1, EIA RS-485, RS-422.
2. USB signal
:
VCC
、
DATA+
、
DATA-
、
GND
、
FG
3. RS-485 signal
:
T+
、
T-
、
GND
4. RS-422 signal
:
T+
、
T-
、
R+
、
R-
、
GND
5. Communication type
:
Asynchronous
communication, Point to point or point to
multi-points, 2 lines of halt-duplex, 4 lines of
full-duplex.
6. Communication control
:
use auto-control
technology to transfer the data, automatic
determine and control the direction of data
transfer.
7. Baud Rate
:
300~921600 bps, automatic
detect the serial port speed.
8. Load ability
:
In point to multi-points each
converter can connects 32 units of RS-422 or
RS-485 interface equipments.
9. Communication distance
:
RS-422/RS-485
5000 meter (9600 bps), USB less than 5
meter
10. Type of communication line
:
Double twist line
or cover line.
11. Communication speed
:
921600 bps 300 M
38400 bps 2.4 KM
9600 bps 5 KM
12. Dimension
:
55mm × 36mm × 18mm
13. Operation environment
:
-25 ~ 70
℃
℃
,
humidity 5% ~ 95%
14. Support Windows95/98/2000/xp
III
、
connection and signal
RS-422/RS-485 export signal
DB9
PINS
Output
RS-422
Duplex
RS-485
Half Duplex
1
T/R+
Transfer(A+)
RS-485(A+)
2
T/R-
Transfer(B-)
RS-485(B-)
3
RXD+
Receive(A+)
Empty
4
RXD-
Receive(B-)
Empty
5
GND
Ground
Ground
6
N/A
7
N/A
8
N/A
9
N/A
IV
、
hardware installment and application
Please read the user manual carefully
before install BF-850, connect the USB to PC.
BF-850 use USB/DB-9 connector, and needs no
crossover set to automatic do RS-422 or RS-485
communication type. You can use double twist
line or cover line, so it’s very convenience to
combine it. T/R+ T/R- represent the transfer and
receive A+/B-, RXD+/RXD- represent the
receive A+/B-, GND represent the public ground
line, point to point, point to multi-points
half-duplex connect to 2 lines T/R+, T/R-, point
to point, point to multi-points full-duplex connect
to 4 lines T/R+, T/R-, RXD+, RXD-.
BF-850 provides 4 types of communication
as below
:
1. point to point/4 lines full-duplex
2. point to multi-points/4 lines full-duplex
3. point to point/2 lines half-duplex
4. point to multi-points/2 lines full-duplex