Installation and Setup Guide

020-103456-01

CounterAct

Summary of Contents for 174-005106-XX

Page 1: ...Installation and Setup Guide 020 103456 01 CounterAct ...

Page 2: ...th the performance or use of this material Manufacturing facilities in Canada and China are ISO 9001 certified For the most current technical documentation and office contact information visit http www christiedigital com Warranty Products are warranted under Christie s standard limited warranty the details of which are available at https www christiedigital com help center warranties or by contac...

Page 3: ...3 Getting to know your device 13 Product components 13 Inserting the disinfecting module in the receiver box 14 Removing the disinfecting module from the receiver box 15 Workflow Installing and setting up CounterAct 17 Planning the layout and power of the site 18 Planning the installation height 18 Setting the lamp mode 19 Registering CounterAct 20 Logging into CounterAct Configure 20 Logging off ...

Page 4: ...9 Setting up devices in CounterAct Configure 39 Creating a room 40 Pairing devices in the application 40 Adding devices to the room 41 Creating a schedule 41 Verifying the optical power output 41 Maintenance and service 43 Replacing the lamps 43 Regulatory 47 Safety 47 Electro magnetic compatibility 47 Emissions 47 Immunity 47 Environmental 47 Radio frequency RF wireless communication 48 Content C...

Page 5: ...product is available in the following documents With the exception of lamp replacements this product is not serviceable in the field and must be sent back to Christie if servicing is required CounterAct Product Safety Guide P N 020 103455 XX CounterAct User Guide P N 020 103457 XX Important safeguards To prevent personal injury and to protect the device from damage read and follow these safety pre...

Page 6: ...od and Drug Administration or the U S Environmental Protection Agency The CounterAct device can produce small amounts of ozone during regular operation When designing the system local regulations must be reviewed to ensure system compliance given the volume of the space characteristics of ventilation access and other factors The device may be used when humans are present but it is not intended to ...

Page 7: ...vice Warning If not avoided the following could result in death or serious injury SHOCK HAZARD Disconnect the product from AC before installing moving servicing cleaning removing components or opening any enclosure ELECTRICAL and BURN HAZARD Use caution when accessing internal components PERSONAL INJURY HAZARD Use caution when servicing the lamp to avoid the risk of personal injury Caution If not ...

Page 8: ...C hazard To avoid eye or skin exposure to unshielded product follow installation and operating instructions Caution If not avoided the following could result in minor or moderate injury Hot surface hazard To avoid personal injury allow the product to cool for the recommended cool down time before touching or handling for maintenance or service Notice If not avoided the following could result in pr...

Page 9: ... according to this guide CounterAct performs according to Risk Group Exempt levels CounterAct overview CounterAct is a commercial UV disinfection fixture containing Ushio Inc s patented Care222 lamps that emit far UVC 222nm light shown to significantly reduce surface pathogens in occupied and unoccupied indoor spaces Care222 is based on far UVC germicidal technology that may also be used around pe...

Page 10: ...r Support Americas christiedigital com Europe Middle East and Africa 44 0 1189 778111 or Support EMEA christiedigital com Asia Pacific support apac christiedigital com Australia 61 0 7 3624 4888 or tech Australia christiedigital com China 86 10 6561 0240 or tech supportChina christiedigital com India 91 80 6708 9999 or tech India christiedigital com Japan 81 3 3599 7481 Singapore 65 6877 8737 or t...

Page 11: ...t Ambient temperature 10 to 60 C 14 to 140 F Ambient humidity 10 to 90 relative humidity Power requirements Learn the power requirements for CounterAct Parameter Requirement AC input UL version Rated voltage 120 VAC maximum single phase Frequency 50 60Hz Rated current 0 5 A maximum Maximum power draw 45 W AC input CE version Rated voltage 220 240 VAC single phase Frequency 50 60 Hz Rated current 0...

Page 12: ...7 mm 1 2 inch flexible metal conduit and fitting or cable gland Safe access to the ceiling is required Optional accessories The following accessories are available for the CounterAct Receiver box with IEC plug black P N 174 102104 XX The IEC receiver box assists with setup prior to installing the unit in the ceiling bench top testings and troubleshooting Use only the attachments and or accessories...

Page 13: ...l power and a quick mounting interface to the disinfecting module B LED status indicator Indicates the status of the device on page 39 C Disinfecting module Contains the ultraviolet lamps modules D Locking pin access Secures the disinfecting module to the receiver box E Ultraviolet lamp module Emits far UVC 222nm light to reduce pathogens F Locking unlocking indicator Indicates the locking and unl...

Page 14: ...les Provides hand holds to mount the disinfecting module to the receiver box Inserting the disinfecting module in the receiver box Insert the disinfecting module in the receiver box and lock the device in position 1 Place the disinfecting module in the receiver box by aligning the slots on the side of the receiver box and the disinfecting module 2 Hold the disinfecting module and turn the disinfec...

Page 15: ...remove it Removing the disinfecting module from the receiver box Remove the disinfecting module from the receiver box to replace lamps 1 Disable power to the system 2 Insert the magnetic driver in the locking hole and turn the locking pin counterclockwise to release it Installation and setup CounterAct Installation and Setup Guide 15 020 103456 01 Rev 1 09 2021 Copyright 2021 Christie Digital Syst...

Page 16: ...eiver box 4 Remove the disinfecting module from the receiver box by pulling the module straight down assuming the receiver box is mounted flush with the ceiling Installation and setup CounterAct Installation and Setup Guide 16 020 103456 01 Rev 1 09 2021 Copyright 2021 Christie Digital Systems USA Inc All rights reserved ...

Page 17: ...n Before installation Pair individual devices now before installing the receiver boxes on page 40 Pairing one device at a time avoids confusion between devices After installation Pair multiple devices at the same time after installing the receiver boxes later in step 9c When pairing devices after installation ensure all the MAC addresses are recorded in advance to distinguish the devices Use the p...

Page 18: ...r the space When Disinfection mode is not on the device is in Standby mode Planning the layout and power of the site Planning the site can help determine the installation position and power to help facilitate pairing and configuration work Christie strongly recommends planning out the site before arriving at the site for installation 1 Make a plan of the installation position for each device For e...

Page 19: ...telligently equalizes the operating hours for the two lamp modules CounterAct must be installed in a ceiling with a minimum height of 6 7 m 22 feet to 8 5 m 28 feet The estimated lamp replacement cycle for CounterAct operating in single lamp mode is double to the lamp replacement cycle operating in dual lamp mode Dual lamp mode Runs both lamps when disinfecting CounterAct must be installed in a ce...

Page 20: ... is connected to the internet the contact and location details are recorded The registration is processed later using this information 4 Log into CounterAct Configure on page 20 with the account you want to use to complete the installation Each time the CounterAct Configure connects to a room it checks if all the devices are registered If not all the devices are registered CounterAct Configure tri...

Page 21: ...Act requires a permanent AC or DC connection to operate The following illustrates the wiring connections required for AC and DC inputs AC input DC input L Live Line Positive G Ground Earth Ground per local code N Neutral Negative 1 Remove the disinfecting module from the receiver box on page 15 to access the power coupler on the receiver box 2 Loosen the screw and move the metal clip toward the ou...

Page 22: ... and less than 12 mm 0 47 inches Metal conduit fitting 12 7 mm 1 2 inch flexible 5 Put the bare ends of the wires into the terminals of the socket 6 Tighten the three terminal screws 7 Place the socket housing back on the receiver box and tighten the screw loosened in step 2 Installation and setup CounterAct Installation and Setup Guide 22 020 103456 01 Rev 1 09 2021 Copyright 2021 Christie Digita...

Page 23: ...e with plate crossbar 174 106108 XX Optional mounting option requiring third party parts junction box and hanger Rotation 180 around vertical axis Static load 6 kg 13 2 lbs Recessed with bridge 174 104106 XX Mounting option included with the product Width 450 to 650 mm 18 to 26 inches horizontal direction Height 10 to 70 mm 0 4 to 2 8 inches vertical direction Rotation 180 around vertical axis Sta...

Page 24: ...afety wire is 45 4 kg 100 lbs For UL rated installations select the appropriate mounting hardware or an equivalent option For earthquake zone considerations as per IBC requirements select the appropriate grade for seismic requirements Caution If not avoided the following could result in minor or moderate injury Ensure load wires and anchoring comply to local building regulations and codes Ensure l...

Page 25: ...ilding regulations and codes Ensure load wires are connected between the receiver box and junction box or according to local building regulations and codes 1 Ensure the power is turned off at the source 2 Remove the two adjacent ceiling panels where the junction box will be installed leaving the T bar between them accessible 3 Remove the tile where you plan to install the receiver box and cut a ro...

Page 26: ...lose to the crossbar and position it with the center hole 10 Align the dowel pins with the first slot and first dowel hole The second dowel hole and slot provide additional 90 orientation adjust range Installation and setup CounterAct Installation and Setup Guide 26 020 103456 01 Rev 1 09 2021 Copyright 2021 Christie Digital Systems USA Inc All rights reserved ...

Page 27: ...g bracket P N 174 104106 XX or an equivalent mounting fixture Caution If not avoided the following could result in minor or moderate injury Ensure load wires and anchoring comply to local building regulations and codes Ensure load wires are connected between the receiver box mounting structure and the load bearing surface higher than the tile according to local building regulations and codes A loa...

Page 28: ...ams 4 Remove the tile where you plan to mount the receiver box and cut a round hole 350 to 360 mm 13 8 to 14 2 inches C in image below in diameter 5 Install the ceiling tile you cut the hole in from step 3 6 Using two M4 screws attach the rotation plate to the top of the receiver box 7 Loosen the two screws by several turns approximately five turns to allow the plate to be rotated smoothly Install...

Page 29: ...bracket to a rigid roof construction 11 Adjust the mounting bracket horizontally to fit the width between the ceiling main beams 12 Adjust the mounting bracket vertically to make the installation flange of receiver box flush with the outer surface of the tile Installation and setup CounterAct Installation and Setup Guide 29 020 103456 01 Rev 1 09 2021 Copyright 2021 Christie Digital Systems USA In...

Page 30: ...eiver box orients along the main beam of the grid ID Description Quantity A M3 screws 3 B Default align mark 1 14 Connect the safety cables between the receiver box and the bracket as required Installation and setup CounterAct Installation and Setup Guide 30 020 103456 01 Rev 1 09 2021 Copyright 2021 Christie Digital Systems USA Inc All rights reserved ...

Page 31: ...te the receiver box in a clockwise directions until it reaches the end of the two short slots 17 Tighten the two screws A in the image below installed in step 6 Installation and setup CounterAct Installation and Setup Guide 31 020 103456 01 Rev 1 09 2021 Copyright 2021 Christie Digital Systems USA Inc All rights reserved ...

Page 32: ...ws ST4 2 X1 20 Connect to power on page 21 21 Install the disinfecting module in the receiver box on page 14 22 Install the ceiling tiles removed in step 2 23 Repeat steps 1 to 22 for each receiver box Installation and setup CounterAct Installation and Setup Guide 32 020 103456 01 Rev 1 09 2021 Copyright 2021 Christie Digital Systems USA Inc All rights reserved ...

Page 33: ... hangers are compatible with CounterAct Erico type Description 51220A 20 T grid span vertical adjustable 512A 512ATC 24 T grid span vertical adjustable 1 Ensure the power is turned off at the source 2 Remove the two adjacent ceiling panels where the block and hanger will be installed leaving the T bar between them accessible 3 Remove the tile unit where you plan to mount the receiver box and cut a...

Page 34: ...er B in the image below using four M3 screws and two Erico commercial hangers A in the image below with primary height and position based on your field measurement ID Description Quantity A Erico hanger 2 B Mounting block adapter 1 Installation and setup CounterAct Installation and Setup Guide 34 020 103456 01 Rev 1 09 2021 Copyright 2021 Christie Digital Systems USA Inc All rights reserved ...

Page 35: ...the two Δ marks are aligned Ensure you tighten the three screws when done ID Description Quantity A M3 screws 3 B Default align mark 1 12 Connect the safety cables between the receiver box and the bracket as required 13 Insert the receiver box through the cut tile and hang it on the bracket with the installed screws from step 8 14 Rotate the receiver box in a clockwise directions until it reaches ...

Page 36: ...nting receiver boxes with the pendant option Pendant mounting works with swing bracket P N 174 105107 XX or an equivalent mounting fixture Caution If not avoided the following could result in minor or moderate injury Safety wires are connected between the receiver box and support clip or according to local building regulations and codes 1 Ensure the power is turned off at the source Installation a...

Page 37: ... up the two screws Changing the position of the two screws and insert nuts to another location can provide an additional 90 orientation adjustment range along Z axis 5 Place the receiver box onto the bottom bracket 6 Tighten up the two screws installed in step 4 and install two more M4 screws D in image below ID Description Quantity A M3 screws 3 B Insert M5 nut 2 C Default align mark 1 D M4 screw...

Page 38: ... 1 C Load wire 1 D Load wire holes 2 11 Add the load wire C and D in the image step 10 to connect the support clip to the load bearing surface higher than the tile according to local building regulations 12 Connect safety cables between the M5 nuts on the top of the receiver box and the holes on the bottom bracket A in the image in step 13 13 Align the holes on the bottom bracket with the holes on...

Page 39: ...roller or configured 2 To power off CounterAct disconnect power at the circuit breaker Make sure to power off CounterAct by turning off the breaker before performing any maintenance or moving within 1 m 3 3 feet of the device LED status indicators Identify the LED state colors and meaning LED State Description Blue Solid Disinfection is in progress Green Solid The device is in Standby mode Red Sol...

Page 40: ...tion use the IEC receiver box P N 174 102104 XX to connect the devices to power 1 Before installing the device into the ceiling connect it to power with the IEC receiver box 2 From the homepage select a room 3 Select Add device On the Add device page the device is listed If the device is not listed select Search 4 To add the device select Add Once a device is added a dialog appears allowing you to...

Page 41: ... plus sign 3 From the Add device page select the new device from the Available Fixtures column After a few seconds the device is added to the room moved to the Added Fixtures column and the Fixture main page is displayed Creating a schedule Create a schedule to determine when you want disinfection to occur 1 From the homepage select Schedule 2 Select the plus sign 3 To add a start time from the Sc...

Page 42: ...8 feet Dual lamp mode the device must be installed in a ceiling with a minimum height of 8 5 m 28 feet 3 Record the measurements in the System and Design Installation Verification Checklist P N 020 103558 XX If additional space is required to record the device measurements add additional forms 4 Provide a copy of the System and Design Installation Verification Checklist P N 020 103558 XX to the cl...

Page 43: ...OT SURFACE HAZARD Do not touch the lamp module during operation HOT SURFACE HAZARD Allow lamp sufficient time to cool before handling SHOCK HAZARD Always turn off power before performing lamp module maintenance FIRE HAZARD Keep all flammable items such as paper or cloth away from the lamp module Use protective eye wear and gloves when handling the lamp module Do not drop hit use force or scratch t...

Page 44: ... Remove the assembly from the bottom cover 6 Remove the two M3 screws holding the lamp assembly in place Maintenance and service CounterAct Installation and Setup Guide 44 020 103456 01 Rev 1 09 2021 Copyright 2021 Christie Digital Systems USA Inc All rights reserved ...

Page 45: ...ll the new lamp P N 174 006107 XX a Connect the LED harness b Install the two screws removed in step 9 to connect the lamp harness to the inverter c Position the new lamp in place on the disinfecting module d Secure the lamp using the two screws removed in step 6 Maintenance and service CounterAct Installation and Setup Guide 45 020 103456 01 Rev 1 09 2021 Copyright 2021 Christie Digital Systems U...

Page 46: ... 14 Re install the disinfecting module on page 14 15 Reset the lamp hours a Ensure you are logged into CounterAct Configure with the installer account b From the homepage select Fixture c From the Fixture page select Reset life d From the Reset life dialog select the lamp you want to reset The fixture life is reset 16 Ensure you dispose of lamps according to local regulations Maintenance and servi...

Page 47: ... IEC 61000 3 2 EN61000 3 2 Limits for Harmonic Current Emissions IEC 61000 3 3 EN61000 3 3 Limitations of Voltage Changes Voltage Fluctuations and Flicker Immunity EN 61547 Immunity Equipment for general lighting purpose Environmental EU Directive 2011 65 EU on the restriction of the uses of certain hazardous substances RoHS in electrical and electronic equipment and the applicable official amendm...

Page 48: ...ctrical and electronic equipment WEEE and the applicable official amendment s China packaging recycling mark standard GB18455 2001 Radio frequency RF wireless communication EN 300 328 V2 2 2 2019 07 EN 301 489 1 V1 9 2 2011 09 EN 301 489 17 V2 2 1 2012 09 Regulatory CounterAct Installation and Setup Guide 48 020 103456 01 Rev 1 09 2021 Copyright 2021 Christie Digital Systems USA Inc All rights res...

Page 49: ......