background image

 

ASSEMBLY & STARTING YOUR CIGAR OASIS PLUS 3.0

 

 
Remove  all  contents  from  the  box  and  remove  all  plastic  wrap.  
Locate the water cartridge which must be filled with 

distilled

 

water 

only 

(see refill instructions below).   

1)  Place the cartridge on a table with the Cigar Oasis sticker 

facing you.   

2)  Place the control top with the screen on the left side on top 

of the cartridge while aligning the notches on both pieces.   

3)  Hold the cartridge in place while sliding the control top left 

(push from the logo side) until it locks into place. 

4)  Connect the ribbon cable 

A

 to the port on the PLUS 3.0 unit 

A

.  The flat part of the ribbon cable will slide out the side of 

the humidor or through the hinges at either corner.    

5)  Connect the Ribbon Cable 

B

 to the Micro USB cable 

B

.   

6)  Then connect 

C

 to the Adapter 

C

 and plug into an outlet.  

 

 

Cartridge Refill Instructions 

1)  Pour 

distilled water

 

only 

into large opening in the center 

of the cartridge and wait for water to absorb.  Repeat until 
cartridge stops absorbing water. 

2)  Empty all remaining water out of the cartridge so only damp 

foam  remains.    **

No  water  should  drip  out  when  the 

cartridge is held upside down**.

 

3)  Dry off the cartridge and put the unit back together.  

 

USING YOUR CIGAR OASIS PLUS 3.0 

  Once the unit is put together and plugged in, it turns on after 

a  few  seconds  of  powering  up  and  then  it  will  read  the 
current humidity.  The unit is factory preset at 70% humidity.  
As soon as the humidity drops below 70% the fan will come 
on to add moisture to the humidor. 

  To raise or lower the humidity settings use the 

UP

 or 

DOWN

 

arrows.   

  When  the unit needs to be refilled  with  distilled water,  the 

Low Water

 and 

Alert

 icons will flash on display.   

 

  When the cartridge is refilled and the unit gets to the setpoint 

the icons will shut off. 

 

Change Temperature Between Fahrenheit and Celsius 

1)  Hold the 

CIRCLE

 button until the

 F

 or 

C

 start flashing. 

2)  Press the 

UP

 arrow to select Celsius or Fahrenheit. 

3)  Hold the 

CIRCLE

 button down until 

or 

C

 stop flashing to 

save the changes. 

 

Calibrate Humidity 

1)  Hold the 

CIRCLE

 and 

UP

 arrow until the screen displays 

U

2)  Use 

UP

 and 

DOWN

 arrows to raise or lower hu-9%. 

3)  Hold the 

CIRCLE

 and 

UP

 arrow to save the changes. 

 

Set UP Wi-Fi 

If you would like to have access to your 

PLUS 3.0

 from your phone 

 

App.  Create an account and follow the instructions in the app to 
setup.  While setting up you will be prompted to download a Setup 
App to connect to your network. 
 

 