background image

FUZZYSCAN FAMILY

Quick Start Guide

Bluetooth  Version

CORDLESS SCANNER

Summary of Contents for A660BT Series

Page 1: ...FUZZYSCAN FAMILY Quick Start Guide Bluetooth Version CORDLESS SCANNER...

Page 2: ...ing performance but also delivers the convenience and freedom of mobility It s ideal for a broad range of applications to unleash your productivity with ease This document provides a quick reference f...

Page 3: ...the status indicator will be steady green Please charge the new battery pack for 8 hours before its first use Ensure the battery contacts of the battery pack are facing the charging contacts inside t...

Page 4: ...fers the legacy cabled interfaces to the host device including USB HID USB COM and RS232 Serial PICO Mode For the requirement of multiple connections up to 7 scanners can be connected to one smart cra...

Page 5: ...cking sounds and its link indicator will flash blue rapidly Once pairing is completed the scanner will beep 4 times in ascending tone and its link indicator will flash blue every 2 5 seconds The smart...

Page 6: ...indicators will then emit alternating red and green blinks Uninstall Scan the Quick Pair barcode for PICO mode which you have created in advance with your scanner This will launch the pairing process...

Page 7: ...xecute the Bluetooth Discovery procedure to find nearby Bluetooth device then select F L A xxxBT xxxx the xxxx are the last 4 digits of its MAC address The scanner will emit 4 beeps in ascending tone...

Page 8: ...ries of clicking sounds and its link indicators will flash blue rapidly Launch your terminal application to connect it with the scanner The scanner will emit 4 beeps in ascending tone to indicate radi...

Page 9: ...anner is successfully discovered Perform the steps required on your host device to activate the pairing e g tapping or double clicking on the model number etc During the pairing process the scanner wi...

Page 10: ...to indicate the radio connection rebuilt and the scanner s link indicators blink blue once per 2 5 seconds At the same time all the stored scanned data will be transmitted automatically right after t...

Page 11: ...is full If the storage is full you will hear 2 long beeps and the status indicator will give 2 red blinks to indicate out of storage To terminate the batch scanning please scan the Exit Batch Scanning...

Page 12: ...Transmit Stored Data The scanner is preset to transmit all stored data by scanning the Transmit Stored Data command During the transmission the scanner will emit continuous short clicks and the link...

Page 13: ...Simple Mode UNINSTALL Host Interface Quick Set for Smart Cradle only RS232 Serial USB HID Standard Mode USB HID Turbo Mode USB Com Port Emulation Keyboard Layout Quick Set USA Latin America United Ki...

Page 14: ...aging Master Default PowerTool Host Link Switch On screen Keyboard Save Configuration Factory Default Power Off Clone Operation Mode Quick Set Trigger Mode Presentation Mode Option Codes 0 8 4 C 1 9 5...

Page 15: ...ed blink 8 beeps Good read 1 green blink 1 good read beep Under Configuration Steady red Off Uninstall state Alternative red and green blinks Off Upgrade state Steady red Short click Time out warning...

Page 16: ...om the date of shipment provided that the product is operated under normal and proper conditions The warranty provisions and durations are furnished by different warranty programs The above warranty d...