background image

 

Ph: 403.258.3100 \ email:info@guardiantelecom.com \ www.guardiantelecom.com  

 

 

 

Page/Talk Indoor Housing 

 

Installation & Operation 

 

 

 

P5520 

P5521

 

 
 

 

P006114 Rev. C 171030 10/30/2017 12:37 PM 

Summary of Contents for Guardian P5520

Page 1: ...Ph 403 258 3100 email info guardiantelecom com www guardiantelecom com Page Talk Indoor Housing Installation Operation P5520 P5521 P006114 Rev C 171030 10 30 2017 12 37 PM ...

Page 2: ...urn 13 Page Talk System Models and Options 14 Typical Installation 15 Table of Figures Figure 1 Features With Optional Desk Set Connector 4 Figure 2 Dimensions 5 Figure 3 Mounting 5 Figure 4 Wiring Photo 6 Figure 5 Installation Photo 7 Figure 6 Crossbar Assembly Photo 7 Figure 7 Wiring 8 Figure 8 Electrical Connections 8 Figure 9 Maximum Speaker Cable Runs to Limit Volume Loss to 1dB 9 Package Con...

Page 3: ...ation of a connector in the event that the station is used as a desk set amplifier Features Construction 16 gauge steel zinc dichromate plated and powder coated Cable Entrances knockouts are provided at convenient locations Mounting kits are available for pole mounting and flush mount installations hole spacing for wall mounting is industry standard Connectors removable screw and plug Combicon con...

Page 4: ...Guardian Telecom Installation and Operation Page Talk Indoor Housing Page 4 Figure 1 Features With Optional Desk Set Connector ...

Page 5: ...Guardian Telecom Installation and Operation Page Talk Indoor Housing Page 5 Figure 2 Dimensions Figure 3 Mounting ...

Page 6: ... Wiring Photo Note Total impedance on the amplifier circuit should not be less than eight ohms for continuous operation such as background music and not less than four ohms for intermittent operation such as paging Suitable resistors can be wired in series or in parallel with speakers to maintain an acceptable impedance ...

Page 7: ...Guardian Telecom Installation and Operation Page Talk Indoor Housing Page 7 Figure 5 Installation Photo Figure 6 Crossbar Assembly Photo ...

Page 8: ... J3A 1B L Brown Red J2A J3A 2A Channel 2 Violet 18 AWG J2A J3A 2B L Brown Violet J2A J3A 3A Channel 3 Blue 18 AWG J2A J3A 3B L Brown Blue J2A J3A 4A Channel 4 Brown 18 AWG J2A J3A 4B L Brown Brown J2A J3A 5A Channel 5 Yellow 18 AWG J2A J3A 5B L Brown Yellow Group Muting of J2A J3A Mute Orange 18 AWG Loudspeakers J2A J3A Park Spare Conductor Special Order n a Extra Red 12 AWG Note Channels 2 to 5 c...

Page 9: ...re and dust See Figure 3 Mounting If this is a new installation use the template provided or the housing itself to locate and drill holes for mounting screws See Insert Template Secure the unit to the wall Ensure that none of the electrical connection circuits are live Bring cable s into the enclosure through the conduit entrance s and attach individual wires to the Combicon connector s Attach the...

Page 10: ...hen a paging call is made from any station in the group including the associated station Note Paging calls originating from stations outside the group will be heard regardless of the position of the Mute jumper If it is desired to bypass a station in a group connect the group paging wires to the PARK terminals of that station EXAMPLE OF GROUP MUTING If the Group Mute Signal Conductors are attached...

Page 11: ...US AREAS WHEN INSTALLED IN CONFORMANCE WITH CSA CERTIFICATE OF COMPLIANCE 1289924 LR65547 SEE MANUAL NUMBER P006257 FOR DETAILS Installation Cable Listing Part No Description Part No Description P006183 2 Conductor 18AWG Armored Speaker P005863 8 Conductor Armored Single Line System P006184 2 Conductor 18AWG Standard Speaker P005916 8 Conductor Standard Single Line System P006217 4 Conductor 18AWG...

Page 12: ...tages may be present in this product ensure that power is removed before installing performing maintenance or making repairs Service Telephone Number 1 800 363 8010 Toll Free in North America Guardian Telecom provides a customer service telephone number which is toll free within North America If you need assistance when installing or operating this product please call the toll free telephone numbe...

Page 13: ... calling the service telephone number given in this manual After providing information on the product the owner and the nature of the problem Guardian will issue a RMA number to be shown on documentation returned with the product In addition to the RMA number shipping documents should include name address and telephone number of the owner along with contact information for the person responsible f...

Page 14: ...PTI P5980 Line Balance Assembly LBU Alarm Tone Generator AG 17 P5960 With Relay P5970 Without Relay Acoustic Booths P9010 AB100 Aluminum or Steel full size P9035 AB1000 Glass Reinforced Plastic hood P9029 AB2000 Glass Reinforced Plastic full size Cable 2 Conductor 18AWG Industrial Armored Speaker Cable 2 Conductor 18AWG Industrial Standard Speaker Cable P006217 4 Conductor 18AWG Industrial Armored...

Page 15: ...Guardian Telecom Inc Installation and Operation Page Talk Indoor Housing Page 15 Typical Installation ...

Page 16: ...Guardian Telecom Toll free 1 800 363 8010 Phone 403 258 3100 Fax 403 253 4967 www guardiantelecom com E mail sales guardiantelecom com Click to open message box CONNECTED PROTECTED Guardian Telecom 2017 ...

Reviews: