background image

 

                              Check Weigher Scales  
                                                 CW Series          

                                       

 

                                                 

 

 

 
 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

 
 

0.00

Summary of Contents for CW series

Page 1: ...Check Weigher Scales CW Series 0 00 ...

Page 2: ...fficient to power the scale 2 When is displayed plug in the AC adaptor for operations or replace new batteries AC ADAPTOR OPERATION Note Always fit the Adaptor to the scale BEFORE connecting to an electrical outlet Disconnect from the electrical outlet BEFORE disconnecting the adaptor from the scale SPECIFICATIONS Model CW Capacity 15 kg x 0 005kg 30 kg x 0 01 kg 60 kg x 0 02 kg 150 kg x 0 05 kg T...

Page 3: ...ing weight mode press this key to call out setting value 5 NET GROSS Toggle between net and gross weight 6 TARE Put a container on the scale press this key to tare the weight and the tarred value is stored 7 SET 1 Press numerical key 0 9 and then press the SET key to enter into checking weight setting mode 2 In counting mode press the SET key to select sampling quantity 3 In weighing mode press an...

Page 4: ...ose 25 pcs press three times to choose 50 pcs press four times to choose 100 pcs 2 If choose put required sampling quantity on the platform LCD will show 10 pcs and the scale is ready for counting 3 Press MODE key to exit counting mode SET UP CHECK WEIGHING VALUE 1 In weighing mode press numerical key and then press SET key to enter into a checkweighing setup mode The display will show as below 2 ...

Page 5: ...ey and then press CALL key Note If the upper limit is lower than the lower limit the buzzer will beep beep beep to remind the operator the setup is incorrect The device will auto clear the upper check weight and return to the last step upper check weight setup If operator does not key in checkweight within 10 seconds after entering into checkweighing mode the device will auto end the setup Under n...

Page 6: ...can be set as desired for the user Press SET key for 3 seconds to enter setting function mode The scale will go into the following SET MODE Ps CALL key means select SET key means confirm Advance to in order to exit the menu 5 ...

Page 7: ...30 30 010 CW_60 60 020 CW150 150 050 2 Weight unit kg lb lb oz 3 Division 4 Auto off time 120 sec 180 sec 240 sec 300 sec off 5 Calibration Weight full capacity 1 2 of full capacity 1 4 of full capacity 6 Calibration weight unit kg lb 7 Counting mode 8 Trade 6 ...

Page 8: ... when calibration procedure is finished E N D START Press and hold the SET key for 3 seconds to enter into the setting function mode Press CALL key to select and then press SET key to enter Press CALL key to choose calibration weight full 1 2 or 1 4 Press SET key to confirm the calibration weight and exit the mode Then press CALL key to choose CAL_u and press SET key to enter the CAL_u In CAL_u pr...

Page 9: ...00000 150000 150Kg 100Kg 200Lb 80000 120000 2 1 2 of full capacity CAPACITY CALIBRATION WEIGHT KG CALIBRATION WEIGHT LB Span range 15Kg 5Kg 10Lb 40000 60000 30Kg 10Kg 20Lb 40000 60000 60Kg 20Kg 50Lb 32000 60000 150Kg 50Kg 100Lb 40000 60000 3 1 4 of full capacity CAPACITY CALIBRATION WEIGHT KG CALIBRATION WEIGHT LB Span range 15Kg 2Kg 5Lb 16000 24000 30Kg 5Kg 10Lb 20000 30000 60Kg 10Kg 20Lb 16000 3...

Page 10: ...ould ask the maintenance men to check the scale 3 Over Zero This message indicates that operator have too much weight on the scale when operator turned the scale on Solution Remove the excess weight from the scale platform and turn the scale off and then back on If the scale continues to display this message the operator should ask the maintenance me for service 4 Overload If the weighting capacit...

Page 11: ...10 5 Power on zero count over calibration zero 10 Solution Turn the scale off and then back on 6 Power on zero count under calibration zero 10 Solution Turn the scale off and then back on ...