background image

SM-483689 

取 扱 説 明 書  

INSTRUCTION MANUAL

冷凍式エアドライヤ 
ゼロアクア GX シリーズ 

REFRIGERATION AIR DRYER 
Xeroaqua GX Series

GX3203D,GX3206D,GX3208D,GX3211D 

GX5203D,GX5204D,GX5206D,GX5208D

オプション用操作マニュアル 

Operation manual for option 

この取扱説明書はオプション用です。

 

同一添付の取扱説明書(SM-483629)と合せてお読みください。 

This instruction manual is for option, read together with attached manual 
(SM-483629) 

製品をお使いになる前に、この取扱説明書を必ずお読みください。
特に安全に関する記述は、注意深くお読みください。

Please  read  this  instruction  manual  carefully  before  using  this  product, 
particularly the section describing safety.

この取扱説明書は必要な時にすぐ取り出して読めるように大切に保
管しておいてください。 

Retain  this  instruction  manual  with  the  product  for  further  consultation 
whenever necessary.

                                   JUL.2014 2nd edition 

CKD Corporation

Summary of Contents for GX3203D

Page 1: ...option SM 483629 This instruction manual is for option read together with attached manual SM 483629 Please read this instruction manual carefully before using this product particularly the section des...

Page 2: ...1 SM 483689...

Page 3: ...hen person who does not have the basic knowledge or who is not well trained installation operation repair etc Improper operation may cause poor performance of the dryer or may cause accidents We appli...

Page 4: ...e following 2 2 6 Electrical wiring 3 7 Option 3 1 SUS H2 7 SUS name plate Option mark H2 3 2 H3 7 Temporarily export packing Option mark H3 3 3 M3 7 Remote control operation alarm signal output Optio...

Page 5: ...frigerated air dryer Xeroaqua GX series perform at their best Be sure to read this manual before using your dryer Keep this manual together with the dryer In addition the end of attached standard inst...

Page 6: ...2 5 0A R 410A 0 26kg 1 0MPa 50 33kg GX3211D AC200V 1 200 220V 50 60Hz 2 6 2 6 2 9 2 4A GX5203D AC100V 1 100 100 110V 50 60Hz 0 30 0 35 m3 minANR 3 2 2 8 2 8A R 134a 0 14kg 1 0MPa 80 21kg GX5203D AC20...

Page 7: ...not clear or there are any questions contact CKD or distributors before using the dryer 2 2 Electrical wiring H2 H3 N1 SM 483629 M3 3 Electrical wiring of option H2 and H3 and N1are same as a standard...

Page 8: ...rmal open between the terminal NO 3 and 7 Remote stop 2 7 2 7 Remove the jumper wire between terminal NO 2 and 7 So connect the momentary switch non voltage normal close between the terminal NO 2 and...

Page 9: ...4 Copper tube rust proof coating Option mark N1 This option provides painting on copper pipes to improve corrosion resisting performance 4 Dimensions SM 483629 Outside dimensions are same as a standa...

Page 10: ...9 SM 483689 5 Electrical circuit H2 H3 N1 SM 483629 Electrical circuit of option H2 and H3 and N1 are same as a standard Refer to the attached standard instruction manual SM 483629 GX3203D M3 AC100V...

Page 11: ...10 SM 483689 GX3203D M3 AC200V...

Page 12: ...11 SM 483689 GX3206D M3 AC100V GX5203D M3 AC100V...

Page 13: ...12 SM 483689 GX3206D M3 AC200V GX5203D M3 AC200V...

Page 14: ...13 SM 483689 GX3208D M3 AC100V GX5204D M3 AC100V...

Page 15: ...14 SM 483689 GX3208D M3 AC200V GX5204D M3 AC200V...

Page 16: ...15 SM 483689 GX3211D M3 AC100V...

Page 17: ...16 SM 483689 GX3211D M3 AC200V GX5208D M3 AC200V...

Page 18: ...17 SM 483689 GX5206D M3 AC100V...

Page 19: ...18 SM 483689 GX5206D M3 AC200V...

Page 20: ...19 SM 483689...

Reviews: