background image

October 2019

 

 

 

 

 WARNING

 SAFETY LEGEND

This manual is intended as a complete operations manual for owners and users of the Clayton Backpack™ Series HEPA Vacuums and equipment 

packages which incorporate the Clayton Backpack™ Series HEPA Vacuums. Although this manual details maintenance and operation of Clayton 

pneumatic tools in conjunction with the vacuum, these tools may be sold separately or as part of a kit. Pneumatic tools, hoses, or accessories are 

available directly from Clayton Associates, Inc.

 

 

Hearing protection is required when applicable 

PEL (permissible exposure limit) is exceeded.

Respiratory protection is required when  

applicable PEL (permissible exposure limit)  

is exceeded.

Read and understand operator’s manual before 

using this equipment.

Eye protection is required when operating  

this equipment.

WARNING

WARNING

WARNING

WARNING

 

 

 

 

 

 

Scan this QR code for 

online instructions and 

documentation, or visit

www.ClaytonHowTo.com

Safety – Operation – Maintenance

Keep this document in a safe place

Read and understand this manual before operating your air tool

BACKPACK™ HEPA VACUUM SYSTEMS  

Model: BP-125-0

Summary of Contents for BACKPACK HEPA

Page 1: ... available directly from Clayton Associates Inc Hearing protection is required when applicable PEL permissible exposure limit is exceeded Respiratory protection is required when applicable PEL permissible exposure limit is exceeded Read and understand operator s manual before using this equipment Eye protection is required when operating this equipment WARNING WARNING WARNING WARNING Scan this QR ...

Page 2: ...Preparation for Shipping 6 Electric Vacuum Operational Procedures 6 When to Change Vacuum Filters 6 Using the Filter Timer Card 6 Recommended Filter Change Procedure using only one vacuum 6 Recommended Filter Change Procedure using a support vacuum 6 Maintenance 7 HEPA Filter 7 Vacuum Maintenance 7 Troubleshooting Guide for Electric Vacuums 7 Warranty 8 Illustrated Parts Breakdown 9 Repair or Warr...

Page 3: ... flow Keep hair loose clothing fingers and all parts of body away from openings and moving parts Turn off all controls before unplugging Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where they may be present Connect to a properly grounded outlet only See Grounding Instructions Do not pick up anything that is burning or smoking such as cigarettes matches o...

Page 4: ... DOD 6050 5 Hazardous Materials Information System HMIS series publications For each hazardous material used within the Navy a material safety data sheet MSDS is required to be provided and available for review by users Consult your local safety and health staff concerning any questions on hazardous chemicals MSDS personal protective equipment requirements and appropriate handling and emergency pr...

Page 5: ...PA High Efficiency Particulate Air filtered vacuum along with vacuum capable tools can practically eliminate all exposure to airborne dust The procedures herein provide a method for performing surface preparation operations while minimizing the particulate contamination of hazardous dust into the air ground and water This technical manual describes the Clayton Vacuum System and provides operating ...

Page 6: ...ith two positions With the vacuum connected to power turn this switch to the ON position to activate the vacuum motor Turn the switch to the OFF position to deactivate the vacuum The vacuum will now be operational and the hose can be connected to either vacuum shrouded grinders or tools or to cleaning tools for general cleanup When to Change Vacuum Filters Vacuum filter bags should be changed at r...

Page 7: ...cuuming The system is designed to extract dry dust and debris and is not equipped for fluid extraction Vacuuming wet material can ruin the filter system and void the warranty Troubleshooting Guide for Electric Vacuums Symptom Probable Cause Remedy Vacuum will not start Electrical connection has not been made Ensure that the power cord has been plugged into a properly grounded 120 Volt circuit Moto...

Page 8: ...mer provide parts and labor at the customer s site From day 91 onward Clayton will provide parts to the customer s site at no charge and will perform labor at no charge for products returned to its factory at the customer s expense Outside the continental U S Clayton will provide parts to the customer s site at no charge or for products returned to its factory at the customer s expense Clayton wil...

Page 9: ...id for 6 quart add 6 after part number 16 Shoulder and Waist Belt 4 Vacuum Hose 4 17 Screw Shoulder Waist Belt 5 a Hose Cuff Swivel 18 Backrest Pad With 3 M Adhesive 5 b Hose Cuff Non Swivel 19 On Off Rocker Switch 6 Rivet Hose To Lid 20 9 Pigtail Power Cord 50 ft 16 3 SJTW 125V 7 10 Quart Cloth Bag for 6 quart add 6 after part number 21 Strain Relief with Nut Heyco 1 2in dia 8 Micro Lined Filter ...

Page 10: ... products are proudly made in the USA Repair or Warranty Contact Clayton Associates Inc 1650 Oak Street Lakewood New Jersey 08701 P 1 732 363 2100 F 1 732 364 6084 www DustlessMadeSimple com Sales JClayton com ...

Reviews: