August 03, 2021 

Safety – Operation – Maintenance

Keep this document in a safe place

Read and understand this manual before operating your air tool

•  A HEPA Filter must be installed in this vacuum at all times.

•  If this vacuum is used to collect hazardous material, appropriate personal protective equipment may be required.

•  Any alteration to this equipment by a third party will nullify its warranty.

WartHog WH Power Head

Pneumatic Industrial HEPA Vacuum

Models: WH-105-4, WH-107-4, WH-115-4, WH-202-4, WH-205-4, WH-215-4

•  Designed for toxic dust cleanup, housekeeping, and vacuum sanding

•  Dry Recovery Only

WH-4_cover

Scan this QR code for 

online instructions and 

documentation, or visit

www.ClaytonHowTo.com

Summary of Contents for WH-105-4

Page 1: ...understand this manual before operating your air tool A HEPA Filter must be installed in this vacuum at all times If this vacuum is used to collect hazardous material appropriate personal protective equipment may be required Any alteration to this equipment by a third party will nullify its warranty WartHog WH Power Head Pneumatic Industrial HEPA Vacuum Models WH 105 4 WH 107 4 WH 115 4 WH 202 4 W...

Page 2: ... DustlessMadeSimple com Sales JClayton com Page 2 Applications Environments 3 What s In the Box 3 Specifications Requirements 3 Getting Started 4 Compressed Air Fittings 6 Before Each Use 6 Bag Filter Change 7 Safe Filter Change 8 Pre Filter Change 9 HEPA Filter Change 10 Illustrated Parts Breakdown 11 Limited Lifetime Warranty Terms And Conditions 14 ...

Page 3: ...d include bags filters and other components These instructions assume you have both a power head and an appropriate Clayton vacuum tank Refer to the instruction manual included with the vacuum tank for additional information PHYSICAL 603 WH 4 Weight TBD lbs TBD kg Dimensions Diameter x Height 17 00 x 9 25 in 43 2 x 23 5 cm 612 WH 4 Weight TBD lbs TBD kg Dimensions Diameter x Height 12 50 x 9 25 in...

Page 4: ...ate boxes 2 Unbox the vacuum power head 3 Visually inspect the power head to verify that no parts are missing or damaged 4 Familiarize yourself with the power head 5 Power Head Vents NEVER BLOCK THE POWER HEAD VENTS NEVER WRAP THE POWER CORD AROUND THE POWER HEAD VENTS GETTING STARTED WH 4_002 Compressed Air Plug Air In Compressed Air Control Valve Compressed Air Gauge Filter Adapter Compressed Ai...

Page 5: ...om plastic bag 3 Install a new HEPA filter Holding the power head on its side screw the new HEPA filter onto the filter adapter Verify the white inner ring of the HEPA filter is fully seated against the underside of the power head If it is not rotate it clockwise until fully seated Refer to the instructions included with the HEPA cable lock to install the cable lock 4 Attach the power head Positio...

Page 6: ...m open end wrench Remove the compressed air plug with either a 7 8 in 22 mm deep socket or 7 8 in 22 mm open end wrench Install a new compressed air plug Compressed Air Coupler Air Out The Vacuum is supplied with two 1 4 in 6 mm brass high flow compatible industrial interchange compressed air couplers This coupler provides convenient pass through compressed air for an air tool connected to the vac...

Page 7: ...ift the bag out of the tank Dispose of the bag according to company policy 4 Install a new filter bag Unfold and fluff a new filter bag Push the inlet tube into the hole on the cardboard collar of the filter bag Grasp the sides of the cardboard collar and push it all the way onto the inlet tube Verify the bottom of the collar is past the opening on the underside of the inlet tube 5 Verify the HEPA...

Page 8: ...k using the top handle Rotate the support vacuum s Compressed Air Control valve to the ON position to create the downdraft Rotate the primary vacuum s Compressed Air Control valve to the ON position to prevent debris from falling off the HEPA filter Carefully lift the primary vacuum s power head and attached HEPA filter off the tank using the top handle Carefully place the power head on the floor ...

Page 9: ...r every five 5 bag filter changes or when it becomes visibly dirty 1 Safe the vacuum Disconnect the vacuum from the power source Remove all hoses from the vacuum 2 Remove the power head Unlatch the power head from the tank Lift the power head and the attached HEPA filter off the tank using the top handle Carefully place the power head on the floor avoid damaging the HEPA filter 3 Remove the pre fi...

Page 10: ...de Remove the HEPA filter from the box and remove it from the plastic bag 4 Remove the old HEPA filter Holding the power head on its side cut the HEPA cable lock and remove it Unscrew the HEPA filter from the filter adapter Dispose of the HEPA filter according to company policy 5 Install a new HEPA Filter Holding the power head on its side screw the new HEPA filter onto the threaded filter adapter...

Page 11: ... Adapter Brass 1 4 in 5 918 08BH Bulkhead 1 2 x 1 2 Brass 6 924 0502 Valve 1 2 MPT x FPT Ball Valve 7 925 P24R160 01 Gauge Pressure 1 5 in 0 160 psi Panel Mount 8 930 027 Handle Carry Flex Rubber 9 940 011 Fitting Coupler 1 4 in Hiflow x 1 4 MNPT 10 940 08PM FTG Plug 1 2 in MNPT 11 FE103212 HZSM Z Hex Standoff 10 32 MF x 3 4 in SS 12 NE10320608 HNSZ Nut 10 32 Nylon Lock SS Short 13 RE0620 SDSSS Z ...

Page 12: ... Adjustment For SuperHornet 2 600 019 Air Motor WartHog 3 601 021 Filter Adapter WartHog 4 602 812 Can Plastic Muffler Black 5 911 011 Gasket Filter Adapter 6 911 812 Muffler Felt Kit For WartHog Air 7 FE103216 HZSM Z Hex Standoff 10 32 MF x 1 in SS 8 SE103210 PFSM Z Screw FH100 SS 1032 x 625 9 SE103210 ACSM L Screw 10 32 x 5 8 Low Socket Cap SS 10A 601 300B16 Vac Head Base 16 in CRS Black 10B 601...

Page 13: ...reakdown 6xx WH 4 Sheet 3 of 3 Seq Item No Description 1 922 T 25GN 1 4 in OD Nylon Tubing Green 2 922 T 50NGE Tubing 1 2 Polyethylene Orange 3 927 04L 02F FTG Elbow 1 8 FNPT To 1 4 PC 4 927 08L 04 FTG Elbow 1 2 PC To 1 4 MNPT 5 927 08L 08 FTG Elbow 1 2 PC To 1 2 MNPT 6 927 08R04 FTG Reducer 1 2 MPC To 1 4 PC 7 927 08T FTG Union Tee 1 2 PC 8 927 08T 08 FTG Tee 1 2 PC To 1 2 MPT WH 4_007 1 4 7 2 5 ...

Page 14: ...selected service location and repair the product at no charge Clayton personnel will determine the best way to repair the product Past 90 days Clayton will provide parts to the customer s site at no charge or the customer may ship the product to a Clayton selected service location at customer s expense and Clayton will repair the product at no charge and provide return shipping Repair Outside the ...

Page 15: ...THIS PAGE IS INTENTIONALLY BLANK ...

Page 16: ...or Warranty Contact Clayton Associates Inc 1650 Oak Street Lakewood New Jersey 08701 P 1 732 363 2100 F 1 732 364 6084 www DustlessMadeSimple com Sales JClayton com Clayton products are proudly made in the USA ...