background image

OWNER’S MANUAL

Hea ng Center

Clean Energy Heating Systems, LLC

540 Maple Street, Honey Brook, PA 19344

www.CleanEnergyHeatingSystems.com

(888) 519-2347

CE70069

Heating Systems

®

Summary of Contents for 60023

Page 1: ...OWNER S MANUAL Hea ng Center Clean Energy Heating Systems LLC 540 Maple Street Honey Brook PA 19344 www CleanEnergyHeatingSystems com 888 519 2347 CE70069 Heating Systems ...

Page 2: ...demark of Clean Energy Heating Systems LLC Copyright 2015 Clean Energy Heating Systems LLC This manual may not be reproduced or distributed without the prior written permission of Clean Energy Heating Systems LLC 540 Maple Street Honey Brook PA 19344 Subject to change without notice ...

Page 3: ... HEATING CENTER ASSEMBLY 5 Tank and Support Legs Assembly 5 Mounting the Drain Pan 6 Mounting the Pump Assembly 6 Installing the 4 Emergency Vent 7 Installing the 2 Breather Vent 7 MOUNTING THE FURNACE ON THE HEATING CENTER 8 HEATING CENTER EXPANDED VIEW 10 ...

Page 4: ...All oil lines must be constructed of copper steel or brass components DO NOT use rubber plastic or any other inappropriate material for oil lines 3 Be sure to follow all instructions for tank installation in the Owner s Manual WARNING To avoid serious injury or death do not weld or allow open flames within 35 feet of the used oil supply tank Tank and Support Legs Assembly HEATING CENTER ASSEMBLY 1...

Page 5: ...HE FLOOR CE70072 FASTEN FURNACE SUPPORTS TO THE HEATING CENTER X2 HORIZONTAL SUPPORTS X2 Figure 2 Area NOT to screw Furnace Supports to the base of the cabinet FRONT OF FURNACE BURNER NO SCREWS CE 140 45 CE 180 50 62 CE 250 CE 330 68 CE 140 35 40 CE 180 CE 250 47 51 CE 330 BACK OF FURNACE BLOWER CE70150 ...

Page 6: ...iring the metering pump to the furnace Mounting the Pump Assembly Mounting the Drain Pan 1 Refer to Figure 2 2 Assemble the drain pan ball valve and pipe 3 Install the 2 tank bushing in the open port directly below the location of the drain pan on the left side when facing the tank 4 Slide the pipe through the 2 bushing and use two of the provided large self drilling screws to mount the drain pan ...

Page 7: ... 4 Emergency Vent in accordance with all state and local codes Figure 4 Installing the 2 Breather Vent Installing the 2 Breather Vent 1 Refer to Figure 4 2 Use proper 2 pipe and fittings user supplied to install the breather vent according to all state and local codes 2 BREATHER VENT 2 PIPE AND FITTINGS USER SUPPLIED CE70074 ...

Page 8: ... Brackets Review Figure 2 and keep screws out of the no screws area No screws should be in this area to keep from penetrating the bottom of the heat exchanger NOTE To help keep the Heating Center stable it is recommended that braces are added from the support legs to the nearest wall refer to Figure 6 REFER TO THE FURNACE OWNER S MANUAL FOR ADDITIONAL INSTALLATION INFORMATION FURNACE SUPPORTS X2 C...

Page 9: ...9 Figure 6 Adding Braces From the Support Legs to the Wall CE70075 BRACE SECURED TO WALL AND SUPPORT LEGS MIN 2 PLACES ...

Page 10: ... Pack 1 4 20168 Pump Mounting Bracket 1 5 50179 4 Male Tank Emergency Vent 1 6 50187 Vent Weather Resistant Breather 2 1 20218 Furnace Support 2 50185 3 8 Compression X 1 4 MNPT 90o 1 50186 3 8 Compression X 1 4 MNPT 1 60025 Hardware Bag Heating Center 1 80002 Copper Tube 1 2 X 7 FT 1 80003 Copper Tube 3 8 X 10 FT 1 80004 Copper Tube 1 4 X 6 FT 1 75001 Label Large Logo 1 70005 Owner s Manual Heati...