background image

4. Cleave fiber to the appropriate  

measurement. For the Corning type connector 

this measurement = 20mm  from the 2.0 or 

3.0mm jacket to fiber 

1. Slide the appropriate boot onto the 

fiber cable. Slide on the LC trigger after 
installing the boot.

2. Furcation tube installation

Refer to page 2 for detailed instructions

3. Soft peel coating removal

Refer to page 2 for detailed instructions

5. Insert fiber into lead-in tube

Refer to page 2 for detailed instructions

6. Verification light

Refer to page 2 for detailed instructions

•  Cleerline SSF

TM

 can be terminated per standard connector using soft peel coating for buffer measurement if desired. Our exclusive SSF

TM

 coating allows cleave lengths to be 

adjusted to simplify the process of termination.

•  Dependent upon specific connector model/type activator mechanism may need to be placed in the “open” position.
•  SSF

TM

 Fiber does not require the use of alcohol cleaning as the glass is not exposed and is protected with SSF

TM

 proprietary coating. Remove soft peel with fingers only. Alcohol can 

be used if desired.

•  Due to the bend insensitivity of SSF

TM

 fiber, your cleaver may require a wheel height adjustment to be properly cleaved.

This guide assumes proper selection of connector matching cable type.

20

       10              10

(A) SSF

TM

 Fiber = 125µm

(B) Soft Peel* = 250µm
(C) 2.0mm & 3.0mm Jacket

*(A) 10mm from 900/250µm

*12mm Soft Peel is an approx.

This instructional supplements the installation guide for Corning UniCam® connectors.  SSF

TM

 fibers have a integral polymer that 

provides incredible bend and durability properties with a 250 micron soft peel acrylate.  SSF

TM

 fibers can be handled much like 

typical buffered 900um fibers in both strength and durablity.  Following the installation steps in the Corning manual and adding or 
deleting the specific steps as noted for installation with 250um, 900 micron buffered and furcated, or 2.0mm & 3.0mm jacketed 
cables will provide for ease of installation. This instructional illustrates 2.0mm & 3.0mm installation.

For connector installation, unless your connectors include a 900 micron furcation build up tube, please obtain this part from 
Cleerline as it is necessary for optimum termination as noted in this instructional.

(A)

(B)

(C)

To Scale

CLEERLINE

TECHNOLOGY GROUP

TM

cleerlinefiber.com

Revise #3

Cleerline SSF

TM

  Corning Unicam

®

 LC

Termination With: 

SSF

TM

 Jacketed Fiber 2.0mm/3.0mm

Do Not 

Use Strippers

Reviews: