background image

Standard Features of the IntelliGuard 8000

System Components

The IntelliGuard 8000 kit contains the following components:

One Prewired 24-pin Connector Harness 

One PlainView 2 Coded Valet Switch

One Prewired 14-pin Connector Harness

One Medallion Siren

One IntelliGuard 8000 Control Unit

One Hardware Kit

One Digital Dual-Zone Proximity Sensor 4

One User’s Manual

Two Remote Transmitters

Two Window Decals

One Extended Range Receiver

One LED Status Indicator

 In tel liGuard 8000/299

1

q

Lifetime Warranty

q

His & Hers Remote Controls

q

ACG™ 2 (Anti-CodeGrabbing™)

q

Extended Range Receiver

q

Audible Low-Battery Warning

q

Built-In Two-Point Immobilizer™ 

q

Optional Wireless Immobilizer™

q

Digital Dual-Zone Proximity Sensor 4

q

Optional Remotely Adjustable OmniSensor 

q

Patented UltraSecure Coded Valet Mode™

q

Eight-Event TotalRecall™

q

Enhanced User-Selectable AutoArming

q

User-Selectable Remote Valet Mode Entry/Exit

q

Built-In BlackJax Anti-Carjacking System

q

Optional DataPort™ Interface and CliffNet Wizard

Pro™ Software

q

FACT — False Alarm Control and Test

q

Prewired LED, Sensor, Extended Range Receiver and

PlainView 2 Switch Connectors

q

High Output Medallion Siren

q

Dual-Mode “Chirp” Silencing

q

Remote Siren Silencing

q

Remote Door Locking/Unlocking with Built-in Relays

q

User-Selectable AutoLock 

q

User-Selectable AutoUnLock 

q

Integrated Electronic Timer

q

Turbo Timer Output 

q

CliffNet DataPort Accessory Interface

q

Remote Keyless Entry and Accessory Activation Even in

Valet Mode

q

Remote Panic with Smart Locking/Unlocking 

q

Smart Remote Trunk Release

q

Built-In Dual Parking Light Flasher with Onboard Relay

q

Remote-Controlled Courtesy Lighting

q

Patented Smart AutoTesting™ 

q

Patented Malfunction AutoBypass™ with

AutoReMonitoring

q

Patented Smart Prior Intrusion Attempt Alert

q

Patented Remote Control Code Learning and MultiRemote 

Recognition

q

Clear All Remotes

q

Multiple-Car Control

q

High-Luminescence LED Status Indicator with Automatic

Battery-Saving Mode

q

Multiple Sensor/Trigger Inputs

q

Patented SmartPowerUp™ 2

q

Full-Time SecureAccess™ Programming

q

Advanced CMOS Microcomputer

q

Pre-Loomed Wiring

q

Three Auxilliary Outputs with Selectable Output Types

q

AutoActivation of Auxilliary Output C for Window

All-Close

q

Installer-Selectable Door Ajar/Delayed Courtesy Lights

Summary of Contents for IntelliGuard 8000

Page 1: ...ntrol and Test qPrewired LED Sensor Extended Range Receiver and PlainView 2 Switch Connectors qHigh Output Medallion Siren qDual Mode Chirp Silencing qRemote Siren Silencing qRemote Door Locking Unlocking with Built in Relays qUser Selectable AutoLock qUser Selectable AutoUnLock qIntegrated Electronic Timer qTurbo Timer Output qCliffNet DataPort Accessory Interface qRemote Keyless Entry and Access...

Page 2: ...and valet switch ground supply 10 Black Ground 11 White Valet Switch input multi plex 13 Gray Violet Auxilliary Output A output 14 Gray Blue Auxilliary Output B output 15 Gray Red Auxilliary Output C output 16 White Blue Optional remotely adjustable OmniSensor input 17 Yellow Optional airhorns or siren output 18 Red Battery input 12v 19 Black twinlead Medallion Siren output 20 Green Tilt Sensor ar...

Page 3: ...IntelliGuard 8000 299 3 ...

Page 4: ...brake supply 9 Brown Red Interior light supply 10 Gray Door trigger 11 Red Orange Door unlock normally open 12 Red Green Door lock normally open 13 Gray Green Door lock normally closed 14 Gray Orange Door unlock normally closed Wiring Description for the Pigtail Connector Pin Color Connects to 1 Green Blue Ignition output 12v 2 White Blue Starter output 12v 3 White Brown Igntion input 12v 4 White ...

Page 5: ...IntelliGuard 8000 299 5 ...

Page 6: ...witch s locking connectors to the WHITE and BLACK locking connector 5 Remove the adhesive backing and press the switch into place Remotely Adjustable Dual Zone Proximity Sensor This efficient new generation proprietary radar sensor is immune to the wind and temperature variations that cause ultrasonic sensors to false alarm The sensor must be mounted onto a metal surface and face outward into the ...

Page 7: ...on between one second and four minutes Current is limited to 0 15 amp See Installer Programmable Features on page 16 for information on programming the output type and or disabling operation while the system is disarmed Auxilliary Output B with Selectable Output Type The output GRAY BLUE wire can be programmed as either pulsed latched or timed and is activated by transmitting channel 7 from the 16...

Page 8: ... page 16 Please note that since this feature sets the system to arm the instant the courtesy lights turn off the Door Ajar Warning feature will not be available Mandatory RPM Programming NOTE This MANDATORY programming step must be completed for the IntelliGuard 8000 to operate properly 1 Drive the vehicle to a nearby open area and allow the engine to warm up until the RPMs drop to the normal idle...

Page 9: ...or 16 Press the LevelShift button three times This shifts the buttons to level 4 channels 13 16 Then press the corresponding button within the next 7 seconds For instance to transmit channel 14 press the LevelShift button three times then press button 2 The LED on the remote control flashes four times pauses flashes four times etc this indicates level 4 NOTE One second after you stop transmitting ...

Page 10: ...ard 8000 s radar sensor 2 Disarm the system with the remote control 3 Transmit channel 16 on the master remote LevelShift three times then button 4 You will hear one chirp and the LED will turn on 4 Test the Proximity Sensor s primary zone by rapidly leaning through an open window into the passenger compartment You will hear a siren chirp when the primary zone is triggered This should not occur ne...

Page 11: ... false alarms If you wish to test FACT simply 1 Arm the IntelliGuard 8000 with the remote control 2 Wait 10 seconds after the interior light turns off then trigger the Proximity Sensor to activate the siren 3 Do not disarm the system let the siren complete its cycle 4 Attempt to trigger the sensor again The alarm should be silent 5 Unlock and open a door The alarm should sound immediately You may ...

Page 12: ... for about 3 seconds until you hear one siren chirp and the LED turns on to acknowledge program mode entry The IntelliGuard 8000 is now in the Feature Select position for User Programmable Features 5 Select the feature column Press the unmarked button the same number of times as the column number Pause You will then hear the same number of chirps as the column number you have selected audibly conf...

Page 13: ...r five seconds Press marked to turn the siren sound off press unmarked to activate the sound Next siren sound 2 will play for five seconds Press marked to turn the siren sound off unmarked to activate it The system will cycle through all six siren sounds n n NOTE 3 You will hear two chirps when all features are reset n NOTE 4 When you hear two chirps all remote controls will have been erased from ...

Page 14: ...Constant Pulsed 1 chirp 2 chirps Learn PageMate 4 ID NOT USED Must program RPM s AFTER changing this feature n NOTE 1 Once this feature is selected one chirp is provided to indicate that the timer has started You can set this anywhere from one second to 4 minutes When the desired duration has been reached press the unmarked side of the PlainView 2 switch The system responds with two chirps to conf...

Page 15: ...cation 1 flash Digital Dual Zone Proximity Sensor 4 4 2 flashes Optinal Dual Zone OmniSensor 3 flashes Optional Digital Tilt Motion Sensor 4 flashes Door Trigger 5 flashes Trunk Trigger 6 flashes Hood Trigger 7 flashes An attempt was made to turn the ignition ON or start the engine while the system was armed 8 flashes More than three consecutive incorrect valet codes were entered while the system ...

Page 16: ... s electrical system and or the power lock servo motors n Doors unlock You either selected the wrong door lock diagram or connected the wires incorrectly Reconnect the vehicle s power locking system to its original condition then retest the voltages as indicated in the Door Locks section of this binder and wire the locks as indicated n Only one door locks You either selected the wrong door lock di...

Page 17: ... switching door triggers or more than 11 volts if the vehicle has positive switching door triggers also make sure the pin switch is connected to the correct wire If not then the door pin switch or pin switches is either defective or in need of cleaning Step 10 Test the trunk trigger circuit Arm the system then use the key to unlock the trunk n Siren sounds immediately parking lights flash repeated...

Page 18: ...ment o The full alarm sounds This is the correct response proceed to step 16 o No response Check the mounting position and sensitivity adjustment Step 16 Complete and provide all necessary paperwork including n User s Manual must be given to the customer n Adhere the Clifford window decals to the vehicle s windows Step 17 Demonstrate Basic System Operation n Remote Operations o Arming disarming an...

Reviews: