background image

 
 

INSTALLATION MANUAL 

 

 

 
 

 

 
 
 
 
 
 
 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

SILICIUM HYBRID INVERTER

 

 

Summary of Contents for DK INV 2000

Page 1: ...INSTALLATION MANUAL SILICIUM HYBRID INVERTER ...

Page 2: ..._____________________________________6 2 2 Installation modes _______________________________________6 2 3 Minimum installation distances____________________________7 2 4 Side opening ____________________________________________7 2 5 Wall installation__________________________________________8 2 6 Hydraulic connections ____________________________________8 2 7 Condensation discharge_______________...

Page 3: ...oth for conditioning and or heating environments and must be destined for this use only and compatibly with its performance characteristics CLIMASTAR accepts no responsibility either contractual or extra contractual for any damage caused to persons animals of property as a result of incorrect installation adjustment or maintenance or improper use In case of water leaks turn the master switch of th...

Page 4: ...klet Do not modify or intervein on the appliance as this could create dangerous situations and the manufacturer will not be responsible for any damage caused Please beware of the danger of burns Some parts can be hot 1 3 Fundamental safety rules Remember that some basic safety rules should be followed when using a product that uses electricity and water such as It is forbidden that unassisted chil...

Page 5: ...er ranges contain two different models DK INV 2000 and DK INV 6000 suitable for two pipes heating and cooling installations with metal housing and radiant accumulation Duak Kherr front panel 1 5 Nominal technical features TECHNICAL DATA MODEL DK INV 2000 DK INV 6000 Battery water contents l 0 47 1 13 Maximum working pressure bar 10 10 Maximum water inlet temperature ºC 80 80 Minimum inlet water te...

Page 6: ...imeter wall to allow the discharge of the condensation water outside 2 2 Installation modes The following descriptions of the different mounting phases and charts refer to a version of the device with water connections on the left standard version If you have purchased a special unit with the water connections to the right please follow the same instructions ant bear in mind that charts and drawin...

Page 7: ... in the room 2 4 Side opening Without the front panel fitted you can find on the left hand side a cover that protects one screw lift the upper cover and loosen the screw Then you will find another two screws in the lower part loosen them too Then move it slightly to the left and lift the side panel up On the opposite side please do the same ...

Page 8: ...at it fits correctly onto the brackets and check that it is stable 2 6 Hydraulic connections Hybrid 2000 Hybrid 6000 Mínimum pipeline diameter mm 12 16 The choice and sizing of the hydraulic lines must be made by an expert who must operate according to the rules of good technique and the laws in force taking into account that undersized pipes may cause malfunction To proceed with hydraulic connect...

Page 9: ...and green paste to seal the threaded connections the use of Teflon is highly recommended when there is anti freeze in the hydraulic circuit Hydraulic connections lay out 100 mm Water inlet Eurokonus 3 4 Water return Eurokonus 3 4 Condensation discharge fitting 14mm ...

Page 10: ... must be open to the atmosphere and the tube must not be immerged in water to avoid problems of adhesiveness and counter pressure that would interfere with the normal outflow If there is a height difference that could interfere with the outflow of the condensation a pump must be mounted Small draining pump can be installed under the lateral drainage tray such pumps are commonly found in commerce H...

Page 11: ...tic Start the filling by slowly opening the system water filling tap Take a screwdriver and act on the highest air relief valve of the battery water heat exchanger When water starts coming out of the air relief valves of the appliance close them and continue filling until reaching the nominal value set up for the system Check the hydraulic sealing of the junctions It is recommended to repeat these...

Page 12: ... one for the management of a solenoid valve to control the water and another one to manage the heating element of the front DUAL KHERR panel The PCB provides also the possibility of free operation without the water sensor H2 in which case the stationary fan thresholds are ignored For access to inside of the machine and make the electrical connections follow the following steps Detach the suction g...

Page 13: ...e in cooling 20 C functions The board can also operate without probe case in which the minimum and maximum thresholds will be ignored If it connects the resistance run activation procedure and place the probe on the top panel H4 DUAL Kherr Do not connect the output resistance Y2 before you performed the activation process and have connected and correctly positioned the probe H4 H2 Water temperatur...

Page 14: ...sensor Failure on fan motor due to external particle or rotation sensor Failure on water temperature sensor H2 check sensor has 10kΩ Failure in heating element overheat Automatic rearm 35ºC Failure in heating element H4 blocked or not connected S1 grill microswitch activated due to filter cleaning ...

Page 15: ...itch Wait until the parts have cooled down to avoid the risk of burns Do not use abrasive sponges or abrasive or corrosive detergents to avoid damaging the painted surfaces When necessary clean the outer surfaces of the Hybrid Inverter with a soft damp cloth 3 2 Cleaning the air suction filter After a period of continuous operation and in consideration of the concentration of impurities in the air...

Page 16: ... filter on the cooler radiator paying particular attention to introduce the lower flap in its housing It is forbidden to use the device without its mesh filter The device is fitted with a safety switch that prevents the fan from starting if the mobile panel is incorrectly positioned or missing on display After filter cleaning check if the panel is properly mounted ...

Page 17: ...nditioning systems use curtains blinds etc 4 TROUBLESHOOTING In case of water leaks or anomalous functioning immediately cut off the power supply and close the water taps Should one of the following anomalies occur contact an authorized service center or an authorized qualified person but do not intervene personally The ventilation does not activate even if there is hot or cold water in the hydrau...

Page 18: ...ectronic control The fan motor is blocked or burnt out Check the windings of the motor and the free rotation of the fan The micro switch that stops the ventilation when the filter grill is opened does not close correctly Check that by closing the grill the micro switch contact is activated The electrical connections are not correct Check the electrical connections The appliance leaks water during ...

Page 19: ...pipe The condensation discharge does not need an inclination for correct drainage The connection pipes and the valve unit are not insulated well Check the insulation of the pipes The appliance makes a strange noise The fan touches the structure Check the clogging of filters and clean them if necessary The fan is unbalanced The unbalancing causes excessive vibrations of the machine replace the fan ...

Page 20: ...20 CLIMASTAR GLOBAL COMPANY S L Carretera AS 266 OVIEDO PORCEYO Km 7 Pruvia 33192 Llanera Asturias SPAIN Tel 34 985 66 80 80 Fax 34 985 264 751 www climastar es HYBRID INVERTER Installation Rev 270320 ...

Reviews: