 version 1.0.2

Input Voltage

18V-24V DC (24V DC is recommended)

Input Current

150mA (for 24V DC)

I/O Connecons

C-Bus

1 X RJ45

RS-232

1 X RJ45

Output

4 X relay channel-8A per channel

(rising-cage 5mm screw terminals)

Input

1 X digital dry contact input

(pin1 & pin2 from RS-232 port)

Network

2 X RJ45

Pr

oduct Specific

aon

1. Screw holes

2. WAN port

3. LAN port

4. Reset network settings button

5. Output connectors

6. Channel LEDs

7. Control buttons (1-4)

8. Reset & Update Module button

9. Rail mounting clips

10. Internal Gateway status LEDs

11. RS-485 jack

12. Network status LEDs

13. RS-232 LED

14. RS-232 jack

1

2

3

4

Com

1-2

Com

3-4

WAN

LAN

IP GatewayPro

CL-DR-IPGWP-4X8A

LAN WAN

Serial

RS-232

C-Bus

Reset

Default

4

1

1

1

1

6

12

11

2

3

5

7

8

9

10

13

14

Enable/disable Autosave

If autosave funcon  is acv ated, reconnecng  main power will set all outputs to the last status 

(before power outage).

In order to enable/disable autosave   follow steps below consecuv ely and uninterruptedly:

1.

 Disconnect the main power. Hold 

bu

on #1 & #2 simultaneously 

(bu

on’s and LED’s number 

sequence is considered from right to le. as shown in following picture)

 

2.

 Reconnect the main power. Release bu on #2 a er LEDs #1 to #4 flashed. Then release bu on 

#1 a er LEDs #1 and #2 flashed. Power LED will start flashing quickly.

3. 

Press bu on #2, 4 mes.

4. 

To disable/enable autosave mode, press bu on #1. LED #1 will display whether autosave mode is 

disabled or enabled. If it is “on” the autosave mode is enable.

5.

 Press bu on #3 to save the module address and bu on #4 to cancel. 

It is recommended to disable autosave unless it is needed to be enabled.

RS-232

C-Bus

Reset

#2

#3

#4

#1

#2

#3

#4

#1

Module’s LEDs

RS-485: 

This  LED flashes if the module receives valid data packets and will remain “on” for 5 

seconds  when  the  module  is  receiving  invalid  data  packet  from  other  devices  in  same  C-Bus 

network.

In some cases, when a new module is added to C-Bus network, 

all Status LEDs might remain 

“on” 

for 5 seconds. This situaon  must not be considered as an error.

Power:

all Status LEDs flash for 1 second, then 

 When the module is connected to main power, 

“Power LED” remains “on”.

RS-232:

This  LED flashes if the module receives valid data packets and will remain “on” for 5 

 

seconds when the module is receiving invalid data packet from Control4 Home Controller.

WAN: 

WAN LED flashes when WAN port is connected to the network switch.

LAN: 

LAN LED flashes when LAN port is connected to the network switch.

Serial: 

This LED flashes when the module sends or receives any data from RS-232 port.

Ch1 to Ch4 :

 Shows the status of module’s relays. 

Change Device Address

The device address is fixed to “1” and is not variable. 