The CE-HD04M Multiplexer enables four HD-SDI signals to be viewed, sequenced 

and output to a single HD-SDI source, as well as an HDMI source. 

INSTALLATION:

1.

  Connect the four HD-SDI cables coming from the cameras to the HD-SDI Inputs. Limit each cable distance to a maximum of 275 feet. 

2.

 Connect the HD-SDI cable from the DVR (or HD-SDI monitor) to the HD-SDI Output. Limit this cable distance to a maximum of 275 feet.  

3.

 To view on an additional monitor, connect an HDMI cable from the monitor to the HDMI Output. Limit this cable distance to a maximum of 25 feet.

4.

 Using the HDMI Resolution Dial, select the desired HDMI display resolution. The output resolution of the device can be found within the resolution setting in the device’s 

OSD. 

NOTE: Resolution should be set to 1080p 30 if connecting to a DVR. Higher frame rates will result in video loss at the DVR.

5.

 Connect a DC12V 0.5A power supply (sold separately) to the power input.

*Distances shown are recommended maximums.

HDMI Resolution

0

12

3

4

5

67

89

AB

C

D

E

F

CONNECTION DIAGRAM:

HD-SDI

INPUTS

6

 

 

 

 

 

 

1  

 

 

 

F

 

 

 

 

 

5

DC12V 0.5A

POWER

CONNECTION

HDMI

OUTPUT

HDMI

RESOLUTION

DIAL

BLINKING GREEN LED:

Good HD-SDI Input Signal,

Current signal being shown on-screen

SOLID GREEN LED:

Good HD-SDI Input Signal

RED LED ON:

Poor HD-SDI Signal

RS485

INPUT

SERVICE PORT

(not user serviceable)

HD-SDI

OUTPUT

HD-SDI DVR (4ch)

HD-SDI

CAMERA

HD-SDI

CAMERA

HD-SDI

CAMERA

HD-SDI

CAMERA

DC12V

1

2

3

4

ch1

ch2

ch3

ch4

1

2

3

4

HDMI MONITOR

HDMI

HD-SDI

cam 1

cam 2

cam 3

cam 4

 25’

M A X

 275’

M

AX

 275’

M A X

Resolution should be set 

to 1080p 30 if connecting 

to a DVR. Higher frame 

rates will result in video 

loss at the DVR.

Summary of Contents for CE-HD04M

Page 1: ...ution setting in the device s OSD NOTE Resolution should be set to 1080p 30 if connecting to a DVR Higher frame rates will result in video loss at the DVR 5 Connect a DC12V 0 5A power supply sold separately to the power input Distances shown are recommended maximums HDMI Resolution 0 1 2 3 4 5 6 7 8 9 ABCDE F CONNECTION DIAGRAM HD SDI INPUTS 6 7 0 1 2 F 4 5 DC12V 0 5A POWER CONNECTION HDMI OUTPUT ...

Page 2: ...UAD QUAD_M SEQ FULL_M1 FULL_M2 DUAL_N DUAL_S DUAL_M Quad Motion QUAD_M All 4 cameras shown quad view as default Switches to 1 camera full screen if motion occurs on 1 channel Switches to 2 cameras side by side if motion occurs on 2 channels simultaneously Switches to quad view if motion occurs on 3 or 4 channels simultaneously 1 2 3 4 2 motion 1 motion 1 motion 1 motion 2 motion 3 motion 4 Quad Vi...

Page 3: ...nnel 2 Press ENTER center press for Dual View Channels 3 4 will not be shown and left and right buttons will not function in this mode 1 2 1 1 2 3 4 enter 1 Dual Mode Not Condensed DUAL N Only 2 channels will be displayed Each channel will display normal height on the screen the edges of the camera image will be cropped off the image will not be condensed Cameras can be shown full screen by use of...

Page 4: ...video loss at the DVR SYSTEM ID System ID is used for RS 485 communication Set to the appropriate setting 1 255 for your RS 485 control BAUDRATE This is the system communication speed used with RS 485 control which supports 2400 4800 9600 and 19200 DE INTERLACE MODE Improve the image quality with De Interlace compensation which reduces image noise when inputting an interlaced signal DEFAULT ALL To...

Reviews: