background image

User Manual

115V & 230V

Coda

®

 ECO

TM

Summary of Contents for ECO 1200

Page 1: ...User Manual 115V 230V Coda ECOTM ...

Page 2: ... Warning Caution 5 Servicing the Coda ECOTM 1200 5 Manufacturing Information 6 Safety Instructions 6 Supply Voltage 6 Packaging 7 Positioning and Placement of the Coda ECOTM 1200 7 Installation and Care 8 Initial Inspection 8 Filter Replacement 8 Mounting the Coda ECOTM 1200 to the Wall 9 Cleaning the Coda ECOTM 1200 9 Warranty 11 Technical Specifications 12 Electromagnetic Emissions 12 Electromag...

Page 3: ... supplier for further information Alternating Current Product Certification Authorized by BSI Catalogue Number Serial Number Temperature Limitation Humidity Limitation Atmospheric Pressure Limitation Canadian Standards Association Consult Instructions For Use RX Only By Prescription Only GS1 DataMatrix Barcode Authorized Representative in the European Community Manufacturer REF SN EC REP ...

Page 4: ...s and low ratings of filters In our study we measured particulate levels of 7000 ppm By installing a Coda ECOTM 1200 you can bring this level to less than 1500 ppm a significant reduction The impact is cleaner air and better health This reduction is important because particulates may carry contaminants onto your samples and into your space The Coda ECOTM 1200 filter will capture more than 1000 har...

Page 5: ...TM 1200 se produiront si l appareil est mis dans une zone humide dans l eau ou sous une fenêtre ouverte N utilisez pas le Coda ECOTM 1200 s il semble avoir été tombé ou endommagé Le droit fédéral États Unis restreint la vente la distribution ou l utilisation de ce dispositif par un médecin agréé ou sur son ordre Warning To avoid risk of electrical shock this equipment must only be connected to a s...

Page 6: ...e Parts Call Customer Service for all other issues Supply Voltage The device reflecting catalogue number GELT 115 operates at a voltage of 115V and the device reflecting the catalogue number GELT 230 operates at a voltage of 230V Make sure the power cord is intact and properly grounded Safety Instructions Manufacturing Information Manufactured By LifeGlobal Group LLC 393 Soundview Rd Guilford CT 0...

Page 7: ...e design of the Coda ECOTM 1200 affords you unlimited possibility in the airflow and purification of the air in your space Our 270 degree design allows the Coda ECOTM 1200 to be placed anywhere in the room Do not expose to direct sunlight Do not expose to flammable gases Operating temperature range is 5 C to 35 C or 41 F to 95 F The 2 speed fan allows you to adjust the speed to accommodate your ro...

Page 8: ...da ECOTM 1200 filters into the side of the unit Make sure it is centered in the opening and upright see diagram to the right 5 Replace the side panel and secure the latch 6 Select the desired location for the placement of the Coda ECOTM 1200 7 Be sure the unit is level and air flow is not impeded by other furniture or objects 8 The unit must be plugged into a properly grounded electrical outlet an...

Page 9: ...ontents Instructions see Figure 2 1 Drill holes to install wall anchoring device using the dimensions shown Refer to instructions with the anchoring device for proper hole size and installation 2 Loop the cable end through a bracket slot then secure the wall mount brackets to the wall Use the oversize washers with the anchoring hardware as shown 3 Attach the two long close eye bolts to the rear of...

Page 10: ...User Manual Coda ECOTM 1200 V2 October 18 2017 Page 10 M CODA 1200 3 4 1 2 17 43 18 cm 1 1 4 3 175 cm 52 1 8 132 4 cm Figure 2 ...

Page 11: ...ilters direct or from a representative to ensure performance and to maintain all your warranties and to know that you are benefiting from the most advanced technology in the market today The unit and filters are warranted for a period of one week for shipping and handling damage If a proper report is not made within this period the damage will not be covered by the company and is now the responsib...

Page 12: ...01 Surge IEC61000 4 6 2001 Conducted RF IEC61000 4 8 2001 Magnetic Fields IEC61000 4 11 2004 Voltage Dips Interruptions and Variations IEC61000 3 2 2006 Harmonic Distortion IEC61000 3 3 2005 Voltage Fluctuations and Flicker Electromagnetic Emissions Guidance and manufacturer s declaration Electromagnetic emissions The Coda ECOTM 1200 is intended for use in the electromagnetic environment specified...

Page 13: ...tage dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 Cycle 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 s 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycle 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 s Mains power quality should be that of a typical commercial o...

Page 14: ...a ECOTM 1200 b Over the frequency range of 150 kHz to 80MHz field strengths should be less than 3 V m Recommended separation distances between portable and mobile RF communications equipment and the Coda ECOTM 1200 The Coda ECOTM 1200 is intended for use in the electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the Coda ECOTM 1200 can help prev...

Page 15: ...ard power cord Make sure the power is ON Q Why is my Coda ECOTM 1200 making unusual sounds A Make sure the filter is installed and sitting in the correct position If there are no problems with any of the above please contact LifeGlobal Group LLC for warranty service LifeGlobal Group LLC 393 Soundview Rd Guilford CT 06437 USA T 1 800 720 6375 F 1 519 826 6947 T 001 519 826 5800 sales LifeGlobal com...

Page 16: ...r Manual Coda ECOTM M CODA 1200 2017 LifeGlobal Group LLC User Manual Coda ECOTM 1200 V2 October 18 2017 T 1 800 720 6375 F 1 519 826 6947 Intl 001 519 826 5800 sales LifeGlobal com www LifeGlobalGroup com ...

Reviews: