background image

1

2009 Audiovox Electronics Corporation. All rights reserved.

PROFESSIONAL

SERIES

Security and Keyless Entry

 Installation Guide

CA 1050

Summary of Contents for Professional Series CA 1050

Page 1: ...1 2009 Audiovox Electronics Corporation All rights reserved PROFESSIONAL SERIES Security and Keyless Entry Installation Guide CA 1050 ...

Page 2: ...arness 8 Additional Ports 12 LED Port 12 Programming Port 12 On Board Shock Sensor 12 Set Up Programming 13 Transmitter Programming 13 Manual Feature Programming 13 Programming Feature Banks 14 Chirp Delete User Accessible 15 Dome Light Delay Theater Dimming 15 Feature Descriptions 15 Transmitter Button Functions 17 Security Trigger Zones 17 System Layout 18 Table of Contents ...

Page 3: ...ar hot surfaces Avoid mounting components or routing wires near moving parts Tape or loom wires under hood for protection and appearance Technical Support 800 421 3209 or go to http techservices codesystems com Use a Digital Multi Meter for testing and verifying circuits DO NOT USE A TEST LIGHT OR COMPUTER SAFE PROBE as these can set off air bags or damage vehicle computers Use grommets when routi...

Page 4: ...4 2009 Audiovox Electronics Corporation All rights reserved 6 Pin Input Output Harness 5 Pin Main Harness 2 Pin Door Lock Output Harness ...

Page 5: ...ive switching Parking Lights Connect the WHITE RED wire to a 15 Amp max fused battery source Connect the WHITE wire to the parking light output wire Negative switching Parking Lights Connect the WHITE RED wire to a good chassis ground Connect the WHITE wire to the parking light output wire 4 BROWN SIREN OUTPUT Locate a suitable mounting location in the engine compartment for the siren away from mo...

Page 6: ...s dome light or door pin switch wire Verification This wire will register positive voltage POS when the door is opened and the interior light is on This wire will register ground or 0 Volts when the door is closed and the interior light is off Connect the PURPLE wire to the vehicle s positive door input wire s NOTE Certain vehicles may require multiple connections Refer to vehicle application guid...

Page 7: ...LOW wire to the vehicle s Ignition wire 6 RED WHITE TRUNK RELEASE OUTPUT Locate the vehicle s trunk release wire at the trunk release switch Verification This wire will register either positive voltage or ground when the trunk release is activated This is a low current output 500mA 3 GREEN DOOR TRIGGER INPUT Locate the vehicle s dome light or door pin switch wire Verification This wire will regist...

Page 8: ...to see which type of door lock system is in your vehicle The most common types are shown in the following diagrams Negative Switching Locks All Door Lock and Unlock Locate the lock unlock wire at the vehicle s lock unlock switch Verification These wires will register ground when the Lock and Unlock switches are activated Connect the GREEN and BLUE wires shown in the diagram below Lock Unlock Vehic...

Page 9: ...sed 12 Volt Battery Souce GREEN Lock Output BLUE Unlock Output Positive Locks Reverse Polarity Locks 5 Wire Door locks All Door Lock and Unlock Locate the lock unlock wire at the vehicle s lock unlock switch Verification These wires will rest at ground and register positive voltage when the Lock and Unlock switches are activated Connect the GREEN and BLUE or BLUE GREEN wires shown in the diagram b...

Page 10: ...GREEN Lock Output BLUE Unlock Output Multiplex Locks 87 87a 86 30 87 87a 86 30 85 85 Fused 12 Volt Battery Source Ground Resistor Positive Multiplexed Locks All Door Lock and Unlock Locate the lock unlock wire at the vehicle s lock unlock switch Verification This wire will show variable positive voltage when the switch is activated Please consult the wire and location chart for specific resistor v...

Page 11: ...g aftermarket actuators not supplied Connect the GREEN and BLUE wires shown in the diagram below using 2 SPDT relays not supplied 30 87 87a 86 85 Fused 12 Volt Battery Source Door Lock Actuator 30 87 87a 86 85 Chassis Ground Chassis Ground GREEN Lock Output BLUE Unlock Output Fused 12 Volt Battery Source M ...

Page 12: ...lue wires from the LED through the hole from the front of the panel Firmly press the body of LED into the hole until fully seated Additional Ports Programming Valet Button Port Select a mounting location that is within reach of the ignition switch as this switch in combination with the ignition switch will be used to program the certain features of the system It is suggested that the switch be mou...

Page 13: ... valet override button 3 Within 10 seconds the system will chirp 3 three times 4 Press 1 button of each transmitter you wish to program 5 The system will respond with 1 chirp for each accepted transmitter 6 Pressing the override button at anytime during programming will advance to the next bank NOTE The system will exit transmitter programming after 15 seconds of inactivity NOTE This system has 1 ...

Page 14: ...Bank 4 2 Press and release to select full trigger 3 Use or to adjust the settings The system will give short chirps upon each press 4 Press for 2 seconds to lock in the change and advance to the lite touch setting the system will give 2 long chirps to confirm 3 Use or to adjust the settings 4 Press and release to lock in the change the system will exit programming and give 1 long chirp to confirm ...

Page 15: ...t turns off the system will then add 2 seconds and then exit the learning mode 4 The LED will begin to flash indicating the system has exited the learning mode and is now armed Chirp Delete User Accessible System ARM DISARM chirps can be toggled ON or OFF without entering the programming feature banks 1 Turn the ignition ON then OFF 2 Press and release the valet programming button 3 times The syst...

Page 16: ...e owners manual Feature Bank 3 Output Control 1 Extended Lock Pulse Controls the timing of the BLUE and GREEN lock output wires 1 Second Single 1 second lock pulse single 1 second unlock pulse 3 5 Seconds Single 3 5 second lock pulse single 3 5 second unlock pulse 1 Second Lock Double Pulse Unlock Single 1 second lock pulse double 1 second unlock pulse 30 Second Lock Double Pulse Unlock Single 30 ...

Page 17: ...ter Button Functions Security Trigger Zones If the security system has been triggered the LED will flash one of the patterns below indicating the zone LED FLASHESTRIGGER ZONE 2 Flashes Hood Trunk Input 3 Flashes Door Input 4 Flashes Shock Sensor 5 Flashes Ignition Input ...

Page 18: ...RUNK PIN INPUT GREEN DOOR TRIGGER INPUT YELLOW IGNITION INPUT ORANGE ARMED OUTPUT RED WHITE TRUNK RELEASE OUTPUT WHITE RED PARKING LIGHT INPUT WHITE PARKING LIGHT OUTPUT BLACK GROUND BROWN SIREN OUTPUT RED BATTERY 12V BLUE UNLOCK OUTPUT GREEN LOCK OUTPUT CA 1050 PROGRAMMING VALET PORT LED PORT ...

Page 19: ...19 2009 Audiovox Electronics Corporation All rights reserved ...

Page 20: ...s and with RSS 210 of Industry Canada Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including any interference that may cause undesired operation Warning Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the...