background image

DataMan

®

60

Quick Reference Guide

2019 October 08
Revision: 6.1.6SR1.5

Summary of Contents for DataMan 60

Page 1: ...DataMan 60 Quick Reference Guide 2019October08 Revision 6 1 6SR1 5 ...

Page 2: ...s in the power supply l Changes or modifications not expressly approved by the party responsible for regulatory compliance could void the user s authority to operate the equipment l Ensure that the cable bend radius begins at least six inches from the connector Cable shielding can be degraded or cables can be damaged or wear out faster if a service loop or bend radius is tighter than 10X the cable...

Page 3: ...lens cap 3 Focal position indicator 4 External illumination connector 5 Status LEDs 6 LED aimer 7 Lens 1 Directly connected cable terminating in a DB15 connector providing power I O USB and RS 232 connectivity 2 Ethernet RJ 45 connector 3 Mounting points 3 ...

Page 4: ...O 00 RS 232 Cable 1 5 m DM100 RS232 000 Extension Cable 5 m DM100 EXTCBL 000 Flying Leads Connection Cable 5 m DM50 PWRIO 05 RS 232 USB adapter connector DM100 PATCH 000 Ethernet Cable use CBL C10E or any standard CAT5 5e SF FTP or S FTP cable OTHER Power Supply 6 V DM100 PWR 000 Pivot Mounting Bracket DM100 PIVOTM 00 Universal Mounting Bracket DM50 UBRK 000 Control Box DM CTRLBOX 00 4 ...

Page 5: ...Dimensions 5 ...

Page 6: ...nces in mm 1D min code 45 mm 33 51 6 MIL 34 51 4 MIL 31 57 8 MIL 30 56 6 MIL 27 60 10 MIL 37 66 10 MIL 25 61 12 MIL 70 mm 44 74 6 MIL 52 73 4 MIL 42 78 8 MIL 45 83 6 MIL 39 80 10 MIL 33 89 10 MIL 34 89 12 MIL 110 mm 58 121 10 MIL 66 122 6 MIL 54 133 12 MIL 50 141 10 MIL 58 168 15 MIL 6 ...

Page 7: ...breakout cable 2 Connect the reader to the PC 3 Connect the reader to an Ethernet network with a standard CAT5 5e SF FTP or S FTP cable For information on the pinout and the wire colors see section Connections Optics and Lighting in the DataMan 60 Reference Manual 7 ...

Page 8: ...ation Note l Cables are sold separately l If a standard component is missing or damaged immediately contact your Cognex Authorized Service Provider ASP or Cognex Technical Support CAUTION All cable connectors are keyed to fit the connectors on the reader Do not force the connections or damage may occur Mounting Mounting the DataMan reader at a slight angle 15 can reduce reflections and improve per...

Page 9: ...or use a tie made of non conductive material to tie them back For RS 232 use the Power Supply return path for ground 1 Verify that the power supply being used is unplugged and not receiving power 2 Connect the cable on the back of the device to an RS 232 adapter cable with power tab 3 Connect a 6 V power supply 4 Restore power to the power supply and turn it on if necessary 9 ...

Page 10: ...supply To configure a DataMan 60 reader the DataMan Setup Tool software must be installed on a networked PC The DataMan Setup Tool is available from the DataMan support site http www cognex com support dataman 1 After installing the software connect the DataMan 60 reader to your PC 2 Launch the DataMan Setup Tool and click Refresh 3 Select your DataMan 60 reader from the list and click Connect 10 ...

Page 11: ...d Codes 1 D barcodes Codabar Code 39 Code 128 and Code 93 Interleaved 2 of 5 Pharma GS1 DataBar Postal UPC EAN JAN 2 D barcodes Data Matrix QR Code and microQR Code MaxiCode RSS CS PDF 417 MicroPDF 417 Discrete I O Operating Limits Output 0 1 IMAX 24 VDC 25 mA VMAX 24 V Output 2 Source VTYP 4 V Sink VIH 4 V VPSU VIL 0 2 V Input 0 Trigger Input 1 VIH 4 26 V VIL 0 2 V ITYP 3 mA Power Supply Requirem...

Page 12: ...88 mm H x V 6 0 µm square pixels Image Resolution pixels 752 x 480 Electronic Shutter Speed 18 µs to 25 ms exposure Image Acquisition up to 60 fps at full resolution Lens Type 6 2 mm F 5 3 focal position M12 lens with IR blocking filter LED Wavelengths The following table shows LED types and the related wavelengths LED λ nm RED 617 12 ...

Page 13: ...r local representative The CE mark on the product indicates that the system has been tested to and conforms with the provisions noted within the 2014 30 EU Electromagnetic Compatibility For further information please contact Cognex Corporation One Vision Drive Natick MA 01760 USA Cognex Corporation shall not be liable for use of our product with equipment i e power supplies personal computers etc ...

Page 14: ...ces for its production It may contain hazardous substances that could impact health and the environment if not properly disposed In order to avoid the dissemination of those substances in our environment and to diminish the pressure on the natural resources we encourage you to use the appropriate take back systems for product disposal Those systems will reuse or recycle most of the materials of th...

Page 15: ...You may also contact your supplier for more information on the environmental performance of this product 15 ...

Page 16: ... provisions of SJ T 11364 这个标签是根据SJ T 11364 的规定准备的 O Indicates that said hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement of GB T26572 2011 表示本部件所有均质材料中含有的有害物质低于GB T26572 2011 的限量要求 X Indicates that said hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement of GB T26...

Page 17: ...Copyright 2019 Cognex Corporation All Rights Reserved ...