background image

Rear Brush 

(Shown Removed)

Lid (Do Not Remove, Shown Removed for Clarity)

Channel

(12 Places)

Rear Bracket 

(Qty: 2)

Front Bracket 

(Qty: 2)

Blank Adapter Plate 

(Shown Removed) 

(Qty: 12)

Mounting Holes 

(Flush Position and 

Protruding Position)

Chassis

Note: 

Mounting Hardware Included, Not Shown

Arrow and “TOP” 

Marking

1

 of 4

Instruction Sheet

408-32067

AMP NETCONNECT  2U Multi-Fiber 

Push-On (MPO) Secure Rack-Mounted 

Enclosure Assembly 1553761-1

Figure 1

1. INTRODUCTION

2U MPO Secure Rack-Mounted Enclosure Assembly 

1553761-1 is used to house and manage MPO Secure 

fiber optic connections. The enclosure fits into a 

standard 483-mm [19.0-in.] Electronic Industries 

Alliance (EIA) rack or cabinet.

Dimensions in this instruction sheet are in metric 

units [with U.S. customary units in brackets]. 

Figures are not drawn to scale.

NOTE

i

To obtain information on AMP NETCONNECT 

products, contact CommScope or visit our 

website at www.commscope.com

 

2. DESCRIPTION

The enclosure consists of a chassis with a lid, 12 blank 

adapter plates (with attaching hardware), 2 front 

mounting brackets, 2 (right and left) rear mounting 

brackets, and mounting hardware. The mounting 

holes in the enclosure chassis provide a choice of two 

positions when mounting the enclosure onto the rack 

or cabinet. See Figure 1. 

The chassis features 12 channels for routing cable 

and a rear brush. The rear brush is used to conceal 

the inside of the chassis. Each channel is marked on 

the front and back of the chassis to identify the 

adapter plate it supports.
The enclosure accepts OM3 Hydra Kits 2193057-[ ], 

SM Hydra Kits 2193758-[ ], and Cable Management 

Adapter Plate Assembly 2111481-1. MPO adapter 

plates are included with the hydra kits.

3. SAFETY PRECAUTIONS

DANGER

STOP

To avoid personal injury, ALWAYS wear eye 

protection when working with optical fibers. 

NEVER look into the end of terminated or 

unterminated optical fibers. Laser radiation is 

invisible, but can still damage eye tissue.

DANGER

STOP

To avoid personal injury, NEVER use defective or 

damaged product. Punctured or stray laser 

radiation may degrade system performance. 

ALWAYS replace defective or damaged product 

immediately.

— DO NOT remove the dust cap plug from a port 

when the port is not in use.

®

FEB 2017 Rev B

To obtain information on

CommScope

® products, visit our website at

www.commscope.com/SupportCenter

©2017 CommScope, Inc. 

All Rights Reserved

This product is covered by one or more U.S.

patents or their foreign equivalents. For patents, see 

www.commscope.com/ProductPatent/ProductPatent.aspx

Summary of Contents for AMP NETCONNECT 2U Multi-Fiber Push-On

Page 1: ...osure chassis provide a choice of two positions when mounting the enclosure onto the rack or cabinet See Figure 1 The chassis features 12 channels for routing cable and a rear brush The rear brush is used to conceal the inside of the chassis Each channel is marked on the front and back of the chassis to identify the adapter plate it supports The enclosure accepts OM3 Hydra Kits 2193057 SM Hydra Ki...

Page 2: ...abinet 4 3 Mount the Enclosure 1 Determine the vertical and horizontal flush or protruding mounting position of the enclosure in the rack or cabinet 2 Using 4 of the 12 24 UNC 2A screws install the 2 rear brackets onto the rack or cabinet 2 screws per bracket 1 bracket per side of rack or cabinet Observe the arrow and TOP marking on each bracket shown in Figure 1 for correct orientation for instal...

Page 3: ...efer to Figure 6 4 Connect the MPO connectors of each trunk cable assembly to the back of an adapter of an MPO adapter plate Make sure to observe the port designations marked on the front of the MPO adapter plates See Figure 7 4 5 Install Adapter Plate s Understand and follow the safety precautions given in Section 3 then proceed with the following 1 Using the captive screw attached to the MPO ada...

Page 4: ...t of the MPO adapter plate See Figure 8 The port designations and color codes are marked on the front of the MPO adapter plate and the MPO adapters are keyed to match the MPO connectors of the hydra cable assemblies 5 REPLACEMENT AND REPAIR DO NOT use defective or damaged product The enclosure is not repairable if damaged Order additional enclosures through your Representative or contact CommScope...

Reviews: