Instruction Sheet

MT- RJ Jack Kits 6278414- [ ], 6278415- [ ],

6278810--[ ], 6278811--[ ], 6588878--[ ], 6588879--[ ],

408--8718

1

of 6

 Feb 2017             Rev H

6588880- [ ], 6693949- [ ], and 6754252- [ ]

Jack Module

Assembly (Qty: 6)

Actuation Key

(Qty: 2)

Icon Wheel

Workstation MT-RJ Jack Kit

Protective Cover

Jack Module

Assembly (Qty: 1)

SL Jack Housing

Actuation

Key (Qty: 1)

Jack Boot

Protective Cover

Simplex Parallel Dress Clip

(Available Separately)

Duplex Parallel Dress Clip

(Available Separately)

900--

µm

Fiber Guide

m

Fiber Guide

Patch Panel MT-RJ Jack Kit

MT--RJ JACK KIT

OPTICAL FIBER SIZE

TYPE

DESCRIPTION

50/125 m

62.5/125 m

XG 50/125 m

Standard Jacks

6588880--1

6588880--2

6588880--3

Patch Panel

MT--RJ SECURE  Jacks

6588879--[ ]

6588878--[ ]

6693949--[ ]

Standard Jacks

[

6278414--[ ]*

6278415--[ ]

1--6278414--2

Workstation

MT--RJ SECURE Jacks

6278811--[ ]

6278810--[ ]

6754252--[ ]

The fiber optic size is marked on the rear underside of the jack module assembly. Size 50/125 is

indicated as “50,” Size 62.5/125” is indicated as “62,” and Size “XG 50/125” is indicated as “XG.”

*

Except --12

Figure 1

1. INTRODUCTION

The MT--RJ jack kits listed in Figure 1 are designed to

terminate 900- m tight buffered optical fiber. The

jacks must be used with 125- m multimode fiber

optic cable only. Read these instructions thoroughly

before assembling the jack kits.

These jack kits cannot be used with build--up

tubes, loose tube fiber, easy--strip fiber,

fan-out kits, or breakout kits.

Dimensions in this instruction sheet are in metric

units [with U.S. customary units in brackets].

Figures are not drawn to scale.

Reasons for reissue of this instruction sheet are

provided in Section 6, REVISION SUMMARY.

The patch panel jacks fit into adapter plates or patch

panels for use in a rack-- or wall--mount enclosures or

enclosures having an adapter plate or patch panel.

NOTE

i

NOTE

i

®

900-- µ

µ

µ

µ

µ

µ

© 

  

2017  CommScope, Inc.

 

All Rights Reserved

 

 

This product is covered by one or more U.S.

patents or their foreign equivalents. For patents, see

www.commscope.com/ProductPatent/ProductPatent.aspx

To obtain information on CommScope   products, visit our website at 

®

 

http://www.commscope.com/SupportCenter

Summary of Contents for MT- RJ 6278414 Series

Page 1: ... 62 and Size XG 50 125 is indicated as XG Except 12 Figure 1 1 INTRODUCTION The MT RJ jack kits listed in Figure 1 are designed to terminate 900 m tight buffered optical fiber The jacks must be used with 125 m multimode fiber optic cable only Read these instructions thoroughly before assembling the jack kits These jack kits cannot be used with build up tubes loose tube fiber easy strip fiber fan o...

Page 2: ...llow the operating instructions 408 series packaged with the tools and safety guidelines packaged with the materials A Required Fiber Optic Combination Strip Tool 1278947 1 408 4577 or 1754708 1 Micro Strip Strip Tool 492109 2 for 900 m buffered fiber Alcohol Fiber Wipe Packet 501857 2 or lint free tissues and isopropyl alcohol greater than 91 99 preferred Fiber Optic Cleaver 1871696 1 408 10086 T...

Page 3: ...ops 2 Place the stripped fiber into the slot so that the end of the buffer is at the 6 mm marking See Figure 3 Detail A 3 While applying pressure on the buffer carefully slide the fiber slide forward toward the carriage until it stops See Figure 3 Detail B 4 Gently close the fiber clamp and slide the carriage forward DO NOT touch the button while sliding the carriage See Figure 3 Detail C 5 Open t...

Page 4: ... the jack on a clean flat surface the protective cover helps to keep the jack stabilized slide the fiber guide onto the back of the jack See Figure 4 The fiber guide is marked with the fiber size Make sure that the marking on the fiber guide corresponds with the fiber size being used Figure 4 Fiber Guide Jack Protective Cover 2 With the handle of the actuation key pointed toward the top of the jac...

Page 5: ... to confirm that the fiber is fully inserted into the fiber hole When the fiber is properly inserted the laser or LED light will diminish in the target area of the jack Refer to Figure 8 If using the visual fault locator avoid contamination to the ferrule end face Make sure that the protective cover remains clean when removed and then before proceeding re install the protective cover onto the jack...

Page 6: ... 9 Jack Boot Installed onto Workstation Jack 3 4 Inspection Remove the protective cover and inspect the ferrule end face for cleanliness using the microscope kit 3 5 Installation Refer to Instruction Sheet 408 8844 for instructions on installing the jacks into the adapter plates patch panels or enclosure or wall box DANGER Never View Active Fiber Signals 4 TESTING Test the system a ttenuation and ...

Reviews: