Mechanical Installation Instructions 

Figure 1:

 Dimensions are for a standard ComNet

™ 

one slot module.

Rack Module:

The unit is designed to be installed in the ComNet 19-inch (483-mm) EIA standard card-cage rack, the C1-US, 
C1-EU, or the C1-CH. Follow these guidelines to install rack cards after performing  module setup procedures.

C1-US, C1-EU, or the C1-CH Card Cage Racks

CAUTION: 

Although the units are hot-swappable and may be installed without turning power off to the rack, 

ComNet recommends that the power supply be turned off and that the rack power supply is disconnected 
from any power source. 

Note:

 Remove electrical connector before installing in card cage rack.

 

1. Make sure that the card is oriented right side up, and slide it into the card guides in the rack until the 

 

    edge connector at the back of the card seats in the corresponding slot in the rack’s connector panel. 

 

    Seating may require thumb pressure on the top and bottom of the card’s front panel.

CAUTION: Take care not to press on any of the LEDs.

 

2. Tighten the two thumb screws on the card until the front panel of the card 

                  is seated against the front of the rack.

FVT/FVR1031

Installation Considerations

This fiber-optic link is supplied as 
a Standalone/Rack module. 
Units should be installed in dry 
locations protected from extremes 
of temperature and humidity.

Standalone Module:

The unit is provided with a mount-
ing plate with holes for two No. 6 pan 
head screws (3-mm or 3.55-mm). 

Attach the module to a solid piece 
of wood using two No. 6 pan head 
wood screws with a minimum 
penetration into the wood of 
3/4 inch. (Screws not supplied) 
See figure 1.

1.  Determine where the module will 

be installed, and ensure that there 
is adequate space at both ends 
for making the various cable 
connections and for reading the 
diagnostic LEDs.

2.  Attach the module to a flat surface 

using two mounting screws.

.156 [3.96 mm]

.313 [7.95 mm]

INS_FVTFVR1031_REVA

07/24/09

Page 1

Summary of Contents for FVT 1031

Page 1: ... s connector panel Seating may require thumb pressure on the top and bottom of the card s front panel CAUTION Take care not to press on any of the LEDs 2 Tighten the two thumb screws on the card until the front panel of the card is seated against the front of the rack FVT FVR1031 Installation Considerations This fiber optic link is supplied as a Standalone Rack module Units should be installed in ...

Page 2: ...or other means of security Access should be limited to service personnel who have been instructed about the reasons for the restrictions to the location Any and all precautions should be taken and controlled by the authority responsible for the location IMPORTANT SAFEGUARDS A Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the ra...

Page 3: ...r other means of security Access should be limited to service personnel who have been instructed about the reasons for the restrictions to the location Any and all precautions should be taken and controlled by the authority responsible for the location IMPORTANT SAFEGUARDS A Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rac...

Page 4: ...32 RS 422 RS 485 2 WIRE BI PHASE or MANCHESTER DATA 1 2 1 2 1 2 LINK VIDEO DATA IN DATA OUT POWER GREEN Communication link has An active video signal is An active data signal is An active data signal is Unit powered up been established over present on the BNC present on the input pins present on the output pins optical fiber connector of the data connector of the data connector RED Communication l...

Page 5: ...se or Manchester DIN DIN DOUT DOUT Data Out Data Out Data In Data In 2 Wire RS 485 DIN DIN DIN DIN Data A Data B Data A Data B Data Transmit Data Receive Signal Ground DIN DOUT GND DOUT DIN GND Data Receive Data Transmit Signal Ground 4 Wire RS 485 DIN DIN DOUT DOUT DOUT DOUT DIN DIN Data Out A Data Out B Data In A Data In B Data In A Data In B Data Out A Data Out B DIN DIN DOUT DOUT DOUT DOUT DIN...

Reviews: