INSTALLATION AND OPERATION MANUAL 

ValueLine 
FVT/FVR412

4-CHANNEL DIGITALLY ENCODED VIDEO
+ 2 BI-DIRECTIONAL DATA CHANNELS 
+ 1 BI-DIRECTIONAL CONTACT CLOSURE

The FVT/FVR412(M)(S)1 Series transmits four (4) channels of video utilizing 

state of the art digital encoding and decoding for high-quality video 

transmission, along with two (2) channels of bi-directional data and one (1) 

bi-directional contact closure over one single mode or multimode optical fiber. 

This equipment is environmentally hardened and suitable for use in 

unconditioned roadside or out-of plant installations. 

The FVT/FVR412 is compatible with NTSC, PAL and SECAM video transmission 

protocols and supports bi-directional RS232, 422 and 485 (2 & 4 Wire) data. 

See

 Figure 4

 on 

Page 3

 for data selection.

See

 Figure 6

 on 

Page 5

 for contact switch positions.

Bi-Color LED indicators are provided to indicate the status of the system, video 

and data. See 

Figure 7

 on 

Page 5

 for LED indication explanations.

These units may be directly plugged into the ComNet Rack (Part C1) or they 

can operate as standalone modules. See 

Figure A

 on 

Page 6

 for mounting 

instructions.

See 

Figures 1 – 7

 for complete installation details. No additional parts or 

power supplies are required. 

Summary of Contents for ValueLine FVT412

Page 1: ...rdened and suitable for use in unconditioned roadside or out of plant installations The FVT FVR412 is compatible with NTSC PAL and SECAM video transmission protocols and supports bi directional RS232 422 and 485 2 4 Wire data See Figure 4 on Page 3 for data selection See Figure 6 on Page 5 for contact switch positions Bi Color LED indicators are provided to indicate the status of the system video ...

Page 2: ...NSMITTER AND RECEIVER FIGURE 3 FVR412 RECEIVER INSTALLATION AND OPERATION MANUAL FVT FVR412 TECH SUPPORT 1 888 678 9427 NOTE Remove Electrical Connector for Rack Mount Units MULTIMODE OR SINGLE MODE OPTICAL FIBER BLACK BLACK WITH WHITE STRIPE REAR PANEL REAR PANEL FRONT PANEL FRONT PANEL ...

Page 3: ...he front panel of the unit Switch 4 RS485 4 Wire 1 2 1 2 1 2 1 2 1 RS232 2 RS422 Bi Phase or Manchester 3 RS485 2 Wire Sensornet 1 RS232 DIN DOUT GND 2 RS422 Bi Phase Manchester DIN DIN DOUT DOUT GND 3 RS485 2 Wire Sensornet DIN DIN GND 4 RS485 4 Wire DIN DIN DOUT DOUT GND Termination Note A 120 ohm termination resistor is applied to the differential inputs when TERM is wired directly to DIN see d...

Page 4: ...ta Out Data Out 2 Wire RS 485 Sensornet DIN DIN DIN DIN Data A Data B Data A Data B Data Transmit Data Receive Signal Ground DIN DOUT GND DOUT DIN GND Data Receive Data Transmit Signal Ground 4 Wire RS 485 DIN DIN DOUT DOUT DOUT DOUT DIN DIN Data Out A Data Out B Data In A Data In B Data In A Data In B Data Out A Data Out B DIN DIN DOUT DOUT DOUT DOUT DIN DIN Data Out Data Out Data In Data In Data...

Page 5: ... down The four CONTACT switches on the front of the unit set the operating mode of the CONTACT OUT terminal pair It can either function as an alarm to indicate fault conditions or it can function as a contact closure to indicate the state of the CONTACT IN terminal pair on the rear of the unit at the other end of the fiber 1 2 3 4 ON OFF OFF OFF Closed when optical Port has established link Open w...

Page 6: ...oriented right side up and slide it into the card guides in the rack until the edge connector at the back of the card seats in the corresponding slot in the rack s connector panel Seating may require thumb pressure on the top and bottom of the card s front panel CAUTION Take care not to press on any of the LEDs 2 Tighten the two thumb screws on the card until the front panel of the card is seated ...

Reviews: