 CircuPool

 Help Guides:   

 

 

 

 

 

 

 

           

RJ-G Series

 

1

 

 

Problem 

Possible Cause 

Corrective Action 

Power LED and  Display Screen 
not turning on. 

Power not connected to unit. 

Check that the Power Module is connected to a 
208240 VAC service, or a 110-120 VAC service. 
Check that the Power Module internal wiring 
matches the voltage 

Circuit Breaker Tripped. 

Verify input voltage with a voltmeter.  If there is 
input power, the circuit breaker may have 
tripped.  The Infinity Series is protected by a 3 
amp circuit breaker located at the base of the 
Power Module. To reset the circuit breaker press 
the small yellow pin back in. Main power to the 
unit must be turned off prior to resetting the 
circuit breaker. Should the circuit breaker 
continue to trip after this exercise then you 
should consult Compu Pool for assistance. 

Loose ribbon cable between 
Power Circuit Board and Display 
Circuit Board. 

Check that the ribbon cable between the Power 
Circuit Board (back) and the Display Circuit Board 
(front) is securely connected.  

Low or no chlorine residual.  

Insufficient chlorine output %. 

Increase chlorine production by pressing the "+" 
button. 

Insufficient running times. 

Increase the operating hours of the pool 
filtration pump and chlorine generator. 

Low stabilizer (cyanuric acid) 
level in pool water 

Add stabilizer to maintain a level of 30 – 60 ppm. 

Ph too high. 

Adjust Ph level to 7.2 – 7.8. 

Temporary loss of chlorine due 
to heavy bather load, rain, 
organic matter. 

Set the unit to Super Chlor and let run for a 24 
hour period. Re-check and if still low take pool 
water sample to pool professional. 

Salt Content below 2500ppm 

Add additional salt to pool to bring salinity 
within 3000 - 4000ppm (3500 ideal) 

Calcified or clogged cell. 

Remove cell from plumbing line and clean 

High nitrates or phosphates in 
pool water. 

Contact pool professional 

Metals present in pool water. 

Contact pool professional 

Water Fault LED on. 
 
 
 
 
 
 
 
 
 
 
 
 

Insufficient or no water flow 
through cell. 

Check that the pump is operating correctly and 
turns on and off with the chlorine generator with 
the timer. 
Ensure that pump strainer baskets are not 
clogged. 
Check that all valves are opened correctly. Check 
for any blockages. 
Clean or backwash filter if dirty. 

Pump speed too low (for multi 
speed pumps). 

Increase the pump speed to ensure consistent 
and sufficient water flow through the Cell. 

No salt in pool water. 

Add salt to pool water to reach required level of 
30004000ppm (3500 ideal) 

Cell Cable not connected to 

Check that the Cell Cable connector is correctly 