IMPORTANT SAFETY INSTRUCTIONS (SAVE THESE INSTRUCTIONS)

This  manual  contains  important  safety  instructions.  

Please  read  and  follow  all  instructions  carefully  during 

installation  and  operation  of  unit.  Read  this  manual 

thoroughly before attempting to unpack, install, or operate.

CAUTION! 

To prevent the risk of fire or electric shock, 

install  in  a  temperature  and  humidity  controlled  indoor 

area,  free  of  conductive  contaminants.  (Please  see 

specifications  for  acceptable  temperature  and  humidity 

range).

CAUTION! 

To reduce the risk of electric shock, do not 

remove the cover except to service the battery.  No user 

serviceable parts inside except for battery.

CAUTION!

 Hazardous live parts inside can be energized 

by  the  battery  even  when  the  AC  input  power  is 

disconnected.

CAUTION! 

UPS  must  be  connected  to  an  AC  power 

DESCRIPTION

Battery/Surge Outlets

Provides 

three 

battery 

powered/surge 

outlets 

for  connected  equipment  and  insures  temporary 

uninterrupted  operation  of  your  equipment  during  a 

power failure.

Full-Time Surge Protection Outlets

Provides three always on surge suppression outlets.

Power Switch

Can  be  used  as  a  mater  on/off  switch  for  equipment 

connected to the battery power supplied outlets.

Power On Indicator

This  LED  is  illuminated  when  the  utility  condition  is 

normal and the UPS outlets are providing power, free of 

surges and spikes.

Electrical Wiring Fault Indicator

This LED indicator will illuminate to warn the user that a 

wiring problem exists, such as bad ground, miss ground 

or reversed wiring. If this is illuminated, user is advised 

to disconnect all electrical equipment from the outlet and 

have an electrician check to ensure the outlet is properly 

wired.

Circuit Breaker

Located on the side of the UPS, the circuit breaker serves 

to  provide  overload  and  fault  protection.  Under  normal 

operating conditions, the circuit breaker is depressed.

Serial Port to PC

This  port  allows  connection  and  communication  from 

the  DB-9  serial  port  on  the  computer  to  the  UPS  unit.  

The UPS communicates its status to the PowerPanel™ 

software. This interface is also compatible with the UPS 

service provided by Windows NT and Windows 2000.

Communication Protection Ports

Communication protection ports will protect any standard 

modem, fax or telephone line.

Outlets Designed for AC Adapters

Allows six AC power adapter blocks to be plugged into 

the UPS without blocking adjacent outlets.

INSPECTION

The box should contain the following:

(1) PowerPanel™ software (floppy disk); (1) serial interface cable (DB-9); 

(1) telephone communication cable; (1) user manual;

(1) USB adapter ; (1) UPS unit.

outlet with fuse or circuit breaker protection.  Do not plug 

into an outlet that is not grounded.   If you need to de-

energize this equipment, turn off and unplug the unit.

CAUTION! 

To avoid electrical shock, turn off the unit and 

unplug it from the AC power source before servicing the 

battery or installing a computer component.

DO  NOT  USE  FOR  MEDICAL  OR  LIFE  SUPPORT 

EQUIPMENT! 

Does not sell products for life support or 

medical applications. 

DO NOT

 use in any circumstance 

that would affect operation or safety of any life support 

equipment  or  with  any  medical  applications  or  patient 

care.

DO  NOT  USE  WITH  OR  NEAR  AQUARIUMS! 

To 

reduce the risk of fire or electric shock, do not use with or 

near an aquarium.  Condensation from the aquarium can 

cause the unit to short out.

Model: 25654

425VA/230W UPS Backup System

5

6

7

8

9

1

2

3

4

Summary of Contents for 25654

Page 1: ...he outlet and have an electrician check to ensure the outlet is properly wired Circuit Breaker Located on the side of the UPS the circuit breaker serves to provide overload and fault protection Under...

Page 2: ...outlets DO NOT plug a laser printer copier space heater vacuum or other large electrical device into the UPS The power demands of these devices will overload and possibly damage the unit 4 To protect...

Page 3: ...ntrol Panel 6 Double click on Add Remove Programs 7 Click the Install Button and follow the on screen instructions 8 When the installation is completed remove the floppy disk For Windows NT 1 Click on...

Page 4: ...er in normal When the power fails the indicator will change to a red color with an X through it 7 Battery OK Indicator This indicator appears in a green color when AC power is normal and the unit and...

Page 5: ...ote The use of the schedule is optional and will have no effect on the shutdown of your system during a power failure This feature is simply used if you want to have your computer automatically shutdo...

Page 6: ...ure 3 The UPS will begin beeping indicating a power failure 4 Save and close any open files 5 Shut down the operating system 6 Once the computer system is shutdown turn the UPS off As the battery disc...

Page 7: ...ery power supplied outlets from its battery Off On Off Utility Failure The UPS is providing battery power Rapid beeps indicate the unit will run out of power shortly Off Off System Overload Occurs whe...

Page 8: ...must be connected to a 110 120v 60Hz outlet The battery is worn out Replace the unit PowerPanel is inactive all icons are gray The serial cable is not connected Connect the serial cable to the UPS un...

Page 9: ...ative Humidity 0 to 95 NON CONDENSING Size Length x Width x Height 9 7 8 x 6 3 16 x 3 1 8 25 8cm x 15 9cm x 8 3cm Net Weight 10 lbs Typical Battery Recharge Time 8 hours typical from total discharge T...