background image

Pearl 

– installation instructions

Electronic push button cabinet lock

Pearl

 — 

Installation

 instructions: 

KEYPAD version 

1

KEYPAD version

Powered by 2-AAAA batteries (included), 

Pearl operates using a 4 to 8 digit code. 

Operation is simple: type a valid code 

and press 

 (enter). Then just turn the 

knob to the unlocked or locked position.

Pearl is easy to install, and offers:

w

 Programmable user 

and supervisor codes

w

 Programmable modes of operation

w

 Programmable reset features

Pearl is intended for interior use only. 

Operating Temperature: 50°F – 120°F 

(10°C – 48°C)

Note:

It is strongly recommended that 

batteries be replaced on an annual 

basis. In the event the batteries are 

exhausted, they can be replaced via 

the external battery compartment.

Thank you for purchasing the CompX

®

 Pearl

.

The Pearl is an innovative solution 

for locking cabinet doors and drawers. It can mount to cabinet doors or drawers 

with a material thickness of 1/32" to 1-7/16".

Summary of Contents for Pearl KEYPAD

Page 1: ...rogrammable user and supervisor codes w Programmable modes of operation w Programmable reset features Pearl is intended for interior use only Operating Temperature 50 F 120 F 10 C 48 C Note It is strongly recommended that batteries be replaced on an annual basis In the event the batteries are exhausted they can be replaced via the external battery compartment Thank you for purchasing the CompX Pea...

Page 2: ... the device in case Pearl ever needs to be reset The remaining green sticker should be saved in a safe and secure location for future reference See page 9 for reset instructions To clean the Pearl surface apply non acid based cleaner to a clean cotton cloth do not spray cleaner directly on the Pearl Wipe down keypad and its respective housing surfaces of excess cleaner Packaged Components Care and...

Page 3: ...be changed when locked or unlocked A small tool like a paper clip or eyeglass screwdriver will be required to open the battery cover Not Included To change batteries 1 Slide down housing base see figure 1 2 Release housing flip up by pressing housing latch tool required see figure 2 3 3 Remove the two AAAA batteries and install the new batteries 4 Close housing flip up and move housing base to the...

Page 4: ...reading the complete programming instructions prior to making any changes Remember to keep track of any programming changes Button locations indicator lights and knob referenced in the programming instructions are shown below Programming Introduction Indicator Lights Green Indicates button input and valid code Yellow Indicates low battery or program mode Red Indicates incorrect entry is the enter ...

Page 5: ...345 Once in programming mode multiple changes can be made prior to exiting programming There is a 10 second programming time limit between each step If Pearl times out or an error is made programming will end and you will need to enter programming mode again 1 Lock must be in the locked position prior to entering programming mode 2 Type supervisor code and press enter Rotate the knob to the unlock...

Page 6: ...programming mode The factory default supervisor code is 12345 supervisor codes must be 4 to 8 digits in length There is a 10 second programming time limit between each step If Pearl times out or an error is made programming will end and you will need to enter programming mode again 1 Place Pearl into programming mode see page 5 2 Press2andthenpress enter 3 Type the current supervisor code and pres...

Page 7: ...ming time limit between each step If Pearl times out or an error is made programming will end and you will need to enter programming mode again 1 Place Pearl into programming mode see page 5 a To turn Single Use Mode ON type 51 and then press enter OR b To return to Standard Mode type 50 and then press enter 2 If successful the green indicator light will illuminate for 1 second Note Returning to S...

Page 8: ...To turn Timeout OFF type 20 and then press enter 3 If successful the green indicator light will illuminate for 1 second Continue programming or press 9 and then enter to exit programming Warning Security Timeout ON will disable the Pearl from use for 5 minutes when 5 invalid attempts to unlock Pearl occur During this time Pearl will not unlock with either the valid user or supervisor code To chang...

Page 9: ...ser Code is called Slot 02 Any additional User Codes reside in memory slots 03 20 To add a user code without specifying a memory slot 03 20 follow the steps on page 5 to enter programming mode User codes must be 4 to 8 digits in length and must be different from all existing codes including Slot 01 Supervisor Slot 02 User codes There is a 10 second programming time limit between each step If Pearl...

Page 10: ...4 Retype memory slot to be added followed by enter 5 Type the new user code and press enter 6 Retype the new user code and press enter 7 If successful the yellow indicator light will illuminate Continue programming or press 9 and then enter to exit programming The Supervisor code memory location is called Slot 01 and the first User code is called Slot 02 The additional user codes reside in memory ...

Page 11: ...Retype memory slot to be vacated followed by enter 5 If successful the yellow indicator light will illuminate Continue programming or press 9 and then enter to exit programming This feature shows the number of times the lock has been operated The number of operations are displayed in yellow light blinks and separated by a green blink to determine the next value Example yellow yellow yellow green y...

Page 12: ...ng WARNING Print this page and measure the line above It is ONE INCH LONG If it measures less than or more than one inch the template measurements also need to be scaled accordingly FAILURE TO DO SO COULD RESULT IN MISDRILLED HOLES 1 Part 334363000000 Copyright2021 CompXSecurityProducts 847 752 2600 compxpearl com 715CenterSt Grayslake IL60030 Any companies and or products referred to herein are m...

Reviews: