background image

©

EMS - eco

Operating Instructions

Release: July 21, 2010

 

1

EMS -

 eco

Easy-Marking-System

Summary of Contents for EMS-eco

Page 1: ... EMS eco Operating Instructions Release July 21 2010 1 EMS eco Easy Marking System ...

Page 2: ... up 6 5 Operation 7 6 Cleaning and product care 10 7 Accessories 11 8 Troubleshooting 12 9 Technical information 13 10 Instructions for packaging the plotter EMS eco 14 11 Safety instructions 15 Plotter EMS eco Operating Instructions 2 EMS eco Easy Marking System ...

Page 3: ...king elements Auto calibration no adjustment necessary Capable of labelling marking elements up to 10 5 mm in height Special solutions for up to 15 mm are possible Universal power supply of 100 240V AC The special start up function for the plotter pens ensures neat labelling right from the very first marking element PC interfaces USB ports Control language HPGL Possible to update EMS eco software ...

Page 4: ...ow Please retain the packaging in case you need to return the device The following items are supplied as standard 1 Plotter EMS eco 2 Power supply with corresponding mains power cord 3 USB cable 4 Operating instructions EMS eco Operating Instructions Release July 21 2010 1 EMS eco Easy Marking System 1 2 3 4 4 ...

Page 5: ...ding support plates 3 Clip adapter for plotter pen 4 Penholder 5 Power supply 6 USB port 7 Control panel control keys 8 Writing arm 9 Plotter pen storage location 10 Interface for optional external devices 3 4 2 Segment 1 Segment 2 2 8 7 9 6 5 1 10 5 ...

Page 6: ...uring it is level Please ensure that the writing arm can move freely and is not obstructed by other objects CONNECTIONS Plug the device into a correctly installed mains socket using the power supply included with the product The power supply features a variable AC input voltage of 100 240V 50 60Hz The power connection can be replaced by way of adapter plugs Plug the connector from the output cable...

Page 7: ...minder signal to re cap and store the plotter pen Delete data downloaded from PC Pause or stop plotter activity ON OFF buttons The ON OFF buttons are used to activate and deactivate the device When the plotter is switched on the writing arm moves to the top right hand corner of the labelling area and auto calibration takes place The green light comes on when the system is ready for use and to rece...

Page 8: ... pen will clog and dry up if it remains un capped in the pen holder Please note To turn off the signal in general please press Clear buffer and beep off together and press ON to start the plotter To re activate the signal please use the same sequence Insert the plotter pen into the pen holder Before using the EMS eco insert the plotter pen with the desired tip width into the clip adapter of the pe...

Page 9: ...ending on the size of the marking elements They can occupy one or two segments on the plotting area Different size fixtures Placing the elements in the fixtures Choose the appropriate fixture for the elements to be labelled and insert the elements carefully into the fixture You can also add the elements first and then place the fixtures on the plotter 1 segment 2 segments 9 ...

Page 10: ...ver the plotter A special dust cover is available as an accessory Wipe the device occasionally after use with a dry lint free cloth or a mild cleaning agent Important Under no circumstances use harsh cleaning products to clean the plotter Never lubricate the mechanical parts of the plotter 10 ...

Page 11: ...7 Accessories Refill Plotter Pen Ink Cartridges Disposable Plotter Pen available in six tip widths available in six tip widths Cleaning Set Pen Cleaner Cleaning Fluid Dust Protection Cap Pen holder 11 ...

Page 12: ...spond to data downloaded from PC Is the interface cable connected properly Replace the data cable if necessary Is the correct interface on the PC being used No labelling is taking place even though a plotter pen has been inserted Check whether the plotter pen has dried out or if there is sufficient ink in the pen Refill or replace the pen if necessary Poor labelling quality uneven line thickness m...

Page 13: ...epeat accuracy after pen change 05 mm with optimum pen Power supply Via separate power supply with exchangeable mains power connection Power supply input voltage 100 240V AC 50 60Hz Power supply input current 7 A max Power supply output voltage 24 V DC Power supply output current 1 25 A max Environmental conditions In use 10 C 35 C 35 75 relative humidity Storage 10 C 50 C 10 90 relative humidity ...

Page 14: ...nstructions for packaging the plotter EMS eco two corner pieces with inlay two corner pieces without inlay center piece covering the y arm inside the white box accessory box inside the white box complete 14 ...

Page 15: ...ed gällande säkerhetsföreskrifter för elektriska apparater Kontrollera uppgifterna på typmärket innan anslutning till eluttag Apparaten får endast användas i torra utrymmen Dra inte ur kontakten ur eluttaget genom att rycka i sladden Reparationer av denna apparat inklusive utbyte av el sladd får endast utföras av fackman Sicherheitshinweise Bewahren Sie die Gebrauchsanweisung sorgfältig auf Dieses...

Page 16: ...es de seguridad en un lugar seguro Este equipo cumple con todas las normas técnicas de seguridad eléctrica y requisitos de seguridad eléctrico aplicables en el país de uso La fuente de alimentación debe corresponderse con los valores de tensión y corriente citados en la placa de identificación del producto Las características de la fuente de alimentación a utilizar con el producto son las siguient...

Reviews: