background image

Introduction Guide

Cloud Data Service

CONTEC CO., LTD.

Summary of Contents for CONPROSYS

Page 1: ...Introduction Guide Cloud Data Service CONTEC CO LTD ...

Page 2: ... check whether the controller is operating properly The setup procedure of the Integrated and the Configurable controllers on a DIN rail or on the wall How to check whether the computer and the controller are communicating properly The setup procedure of the computer IP address How to connect the computer the controller and the power unit The names and positions are illustrated The list of items t...

Page 3: ...unit Individually sold CPS PWD 15AW12 01 recommended The product requires the items listed below to set up Have the followings ready The product requires the items listed below to set up Have the following items ready Controller CONPROSYS product Power cable This comes with the above recommended battery unit AC power cable Individually sold IPC ACCODE3 recommended LAN cable Cross cable Computer Ba...

Page 4: ...ttom See the positions to connect each cable RESET SW1 SD Isolated RS 422A 485 SHUT COM B USB RS 232C TERM MODE SW2 DOWN COM A AI1 AI0 DO1 DO0 DI CNT LAN B LAN A 12 24VDC A B SD TX RX MCOM DIO0 DIO1 DIO2 DIO3 N C PWR ST1 ST2 ERR DIO 0 1 2 3 V V 24VDC SW1 ON ID L H SD A A This layout of the connectors is the example of the multiple I O model Please see an appropriate controller manual for your mode...

Page 5: ...it with AC plug it takes a few minutes for the controller to complete the start up approx 1 2 min 2 AC plug Controller AC power cable LAN cable Computer Battery unit Connection diagram Connect to LAN A Connect to the power connector AC L AC N AC G V V FG Green GND Black 12V Red FG Green N 白 L Black Power cable Power cable AC power cable AC power cable FG Green GND Black 12V Red FG Green N White L ...

Page 6: ...puter After connecting the power unit with AC plug it takes a few minutes for the controller to complete the start up approx 1 2 min 2 AC plug Controller AC power cable LAN cable Computer Battery unit Connection diagram Connect to the power connector Connect to LAN A Power cable AC power cable N L INPUT AC100 240V DC24V 3 8A OUTPUT DC_OK FG Green GND Black 24V Red L Black N White FG Green ...

Page 7: ...ocedure described below and set the network to make the IP addresses as shown The product must set a unique IP address for the bold part 200 or 101 that is not used by other devices on your network Controller The factory default setting Computer IP address 10 1 1 200 Subnet mask 255 0 0 0 IP address 10 1 1 101 Subnet mask 255 0 0 0 Computer Network Setting Procedure for Windows 10 Go on to the nex...

Page 8: ...version 4 TCP IPv4 in Ethernet Properties dialog box 5 In the Internet protocol version 4 TCP IPv4 property set IP address and Subnet mask as shown below 6 Click OK OK Close to close the dialog box and complete the network setting 7 IP address 10 1 1 200 Subnet mask 255 0 0 0 Select ...

Page 9: ...e to this website Start the Internet Explorer 11 on your computer Enter IP address 10 1 1 101 of the controller in the address bar then press Enter key The dialog box asking for the User name and Password appears enter them and click OK 1 If Status menu of Web browser menu appears it indicates the success of the communication between the computer and the controller 2 Status menu screen 10 1 1 101 ...

Page 10: ...troller on the upper part of a DIN rail 2 and press the product to the lower side of the DIN rail 2 Mounting on a DIN Rail Place the controller onto the wall Push up the fixed hooks to lock on the DIN rail 3 Fixed hook 1 1 2 Appropriate screws fit into φ3 5 hole are required to set the product on the wall The screws can be purchased individually ...

Page 11: ...ok on the bottom to unlock preferably with a slotted screwdriver 1 1 Hang the controller on the upper part of a DIN rail 2 and press the product to the lower side of the DIN rail 2 Mounting on a DIN Rail Push up the hook to lock on the DIN rail 3 1 2 Fixed hook 1 2 ...

Page 12: ...a driver to secure the lead wires Lead wires Operation check connector Go on to the next page 10 9 8 7 6 5 4 3 2 1 DO1 DO1 DO0 DO0 DI_MCOM DI3 CNT1 DI2 CNT0 DI1 DI0 N C Pin number Signal name This layout of connector pins is the example of the multiple I O model Please see an appropriate controller manual for your model On your computer start up Internet Explorer 11 and enter IP address 10 1 1 101...

Page 13: ... to show the screen for I O check 4 Click DO0 in Digital Output on the I O check screen of the controller to switch on off This turns on off the DIO0 lamp of Digital Input This confirms that the controller is operating properly 5 Lamp is off Click Lamp turns on ON ...

Page 14: ...n check connector into the digital I O connector of the controller 2 Fasten the screws with a driver to secure the lead wire Go on to the next page Operation check connector 6 5 4 3 2 1 1 2 3 4 5 6 MCOM DIO0 DIO1 DIO2 DIO3 N C Pin number Signal name Lead wires On your computer start up Internet Explorer 11 and enter IP address 10 1 1 101 of the controller in the address bar then press Enter The sc...

Page 15: ...le setting in Maintenance menu and click the Controller image or in the Module list 4 Change those DIO0 DIO1 set in the Step 1 to value DIO0 DI DIO1 D 1O respectively Default settings are all DI Click after setting 5 1 Configure set Module setting Change values ...

Page 16: ...anges PWR LED will be on once the changes are saved saving time approx 20 seconds After completion of the saving click Reboot Shutdown to reboot the controller approx 1 minute 7 To create a monitoring view screen open Monitoring edit in Maintenance menu and change to Run in the Mode that is located on the upper right side save to ROM ...

Page 17: ...ag drop them onto the Layer area 9 1 Click the Switch control on the layer area to activate 2 Click OnPressd in the Property tab on the right side 3 and click icon in the Link Box 4 Select CPU_DO01 in Device Tree and click 5 This connects the Switch and the connector DIO1 Drag Drop Layer area OK 1 2 4 5 3 ...

Page 18: ...he Link Box 4 Select CPU_DI00 in Device Tree and click 5 11 Clicking the Switch on the Layer area turns the Lamp on off This also turns on off the LED of the controller This confirms that the controller is operating properly This connects the Lamp and the connector DIO0 OK 1 2 4 5 3 Click the Switch to turn on off The Lamp turns on off ...

Page 19: ...oubles performances and to stop operations No development environment is required Signal processing can be added easily through Web browser Programming can be done by script language with the controls through Web browser CONPROSYS HMI CONPROSYS VTC Human Machine Interface Visual Task Control Monitoring function Task function Facilities Remote location M2M controller M2M controller Easy creating a ...

Page 20: ...ns Security measures e g Do not keep using the default password Refer to the product manual for the password setting Set a strong password Combined with upper and lowercase letters and numbers so that it cannot be easily analogized by others Change the password periodically Disable unnecessary network services and functions Restrict access to the network with network devices Restrict ports to be r...

Page 21: ... 20 MEMO ...

Page 22: ...233 CHINA Tel 86 21 5401 2288 SINGAPORE CONTEC PTE LTD Blk 4010 Ang Mo Kio Ave 10 07 01 Techplace I 569626 SINGAPORE Tel 65 6459 1667 THE NETHERLANDS KOREA CONTEC CO LTD AMSTERDAM BRANCH WTC Amsterdam Tower C Level 12 Strawinskylaan 1249 1077XX Amsterdam THE NETHERLANDS Tel 31 20 238 0960 CONTEC CO LTD Korea Liaison Office 19 Cheongmyeong ro 21beongil Yeongtong gu Suwon si Gyeonggi do KOREA Tel 82...

Reviews: